Napoleon Fireplaces GD80NT, GD80PT manual Remote and Valve Access, Inner Access Door, Control Door

Page 21

21

REMOTE AND VALVE ACCESS

INNER ACCESS DOOR

The control area can be accessed either through the control door or through the access door inside the firebox.

Follow the door removal instructions. Remove the right side panel. Remove the four screws from the access door.

Note: A new gasket will be required, when re-installing the door (see replacement parts).

CONTROL DOOR

FIGURE 47

1.Remove the hearth strip.

2.Open the right control door.

3.Remove the switch plate by pull- ing on the left side.

4.Remove the valve housing by pulling on the handle.

5.Lift up and set the housing towards the back of the fire place.

FIGURE 46

FIGURE48

REMOTE RECEIVER REMOVAL

1.Unplug the cord from the junction box

2.Pull the the tab on the receiver lock forward.

3.Pull up on the receiver and disconnect the wires.

4.Install the new receiver (see schematic Pg.23).

VALVE REMOVAL

The valve on the Madison is piped with two flex connectors (one inlet, one outlet).

It can be removed or pulled forward for service.

1.Remove the wing nut and pivot the valve out from the slot at the bottom of the valve.

2.Slowly pull the valve through the control door careful not to kink the gas lines or wires.

W415-0447 / B / 05.24.05

Image 21
Contents W415-0447 / B What to do if YOU Smell GAS Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty General Information General InstructionsVenting Care of GLASS, and Plated PartsVenting Lengths & AIR Terminal Locations TOP Exit / Horizontal Termination DefinitionsElbow Vent Length Values V190 TOP Exit Vertical Termination Formula 1 HT 3VT Formula 2 HT + VT 40 feet Example TOP Vertical TerminationAIR Terminal Installations Installation Wall and Ceiling Protection Horizontal InstallationVertical Installation Using Flexible Vent Components Horizontal AIR Terminal InstallationVertical AIR Terminal Installation Using Rigid Vent Components Extended Horizontal AIR Terminal InstallationFireplace Vent Connection Restricting Vertical Vents Vertical Venting Installation GAS InstallationClearance to Combustibles FramingSchematic Hard Wiring ConnectionElectrical Connection Mantle ClearancesLOG Shipping Bracket FinishingBaffle Installation LOG PlacementGlowing Embers Charcoal EmbersLamp Replacement Blower ReplacementInner Access Door Remote and Valve AccessControl Door Remote Receiver RemovalOperation / Maintenance Fireplace OperationHand Held Remote Operation Operating Instructions Maintenance AdjustmentsPilot Burner Adjustment Venturi AdjustmentReplacements W415-0447 / B Symptom Problem Test Solution Trouble Shooting GuideStanding Main