Napoleon Fireplaces GD80PT, GD80NT manual Blower Replacement, Lamp Replacement

Page 20

20

LAMP REPLACEMENT

1.Turn off the power to the unit.

2.Turn off the gas valve.

3.Remove the door and logs.

FIGURE 42

FIGURE 41

4.Loosen the lense retainer screws and pivot the retainers out of the way.

5.Using a small flat screwdriver, gently lift the orange lense from the housing.

6.Slide the defective bulb to either side until the opposite end is disengaged. Remove the bulb lifting the disengaged end.

7.Replace with a 75 watt halogen lamp (E-11 BASE).

Install the replacement bulb using the protective wrap to avoid touching the lense, then disgard the protec-

tive wrap.

8. Repeat steps 5 - 1 for installation.

BLOWER REPLACEMENT

The Napoleon MADISON comes equipped with a heat circu- lating blower. The blower is pre-wired and is controlled by the remote control supplied with the unit. For control details, see operation. Pg . 22.

Drywall dust will penetrate into the blower bearings, causing irreparable damage. Care must be taken to pre- vent drywall dust from coming into contact with the blower or its compartment. Any damage resulting from this condition is not covered by the warranty policy.

1.Turn off the power to the fireplace.

2. Turn off the gas valve.

FIGURE 43

FIGURE 44

4.To remove the lamp assembly, remove the two log locat- ing studs located just behind the main burner. It is not neces- sary to disconnect the wires, the assembly can lay along the right side of the firebox.

FIGURE 45

3.Remove the glass door, logs, rear log support, side brick panels, rear baffle, and rear panel.

5. The blower mounting plate can now be removed. Remove the six screws that secure the plate to the firebox back. The blower is secured to this plate.

6. Disconnect the wire connectors and ground before attempt- ing to remove the blower from the plate.

7. When re-installing the replacement blower, it will be nec- essary to replace the gasket (W290-0091) on the cover plate.

W415-0447 / B / 05.24.05

Image 20
Contents W415-0447 / B What to do if YOU Smell GAS Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty General Instructions General InformationVenting Lengths & AIR Terminal Locations VentingCare of GLASS, and Plated Parts Elbow Vent Length Values TOP Exit / Horizontal TerminationDefinitions V190 TOP Exit Vertical Termination TOP Vertical Termination Formula 1 HT 3VT Formula 2 HT + VT 40 feet ExampleAIR Terminal Installations Vertical Installation Installation Wall and Ceiling ProtectionHorizontal Installation Vertical AIR Terminal Installation Using Flexible Vent ComponentsHorizontal AIR Terminal Installation Fireplace Vent Connection Using Rigid Vent ComponentsExtended Horizontal AIR Terminal Installation Vertical Venting Installation GAS Installation Restricting Vertical VentsFraming Clearance to CombustiblesHard Wiring Connection SchematicElectrical Connection Mantle ClearancesFinishing LOG Shipping BracketLOG Placement Baffle InstallationGlowing Embers Charcoal EmbersBlower Replacement Lamp ReplacementRemote and Valve Access Inner Access DoorControl Door Remote Receiver RemovalHand Held Remote Operation Operation / MaintenanceFireplace Operation Operating Instructions Adjustments MaintenancePilot Burner Adjustment Venturi AdjustmentReplacements W415-0447 / B Trouble Shooting Guide Symptom Problem Test SolutionStanding Main