Vermont Casting Complete Guide to FK26 Fan Kit Installation | s Radiance Manual

Page 10

Vermont Castings Radiance

Install Optional Fan, #2767/FK26

Install the fan kit before the stove is connected to the gas line.

The fan consists of a blower assembly and a rheostat switch that are connected by a wire harness. The blower attaches to brackets at the bottom of the rear shroud. The rheostat installs within the remote switch box, at the top left rear corner.

The fan kit includes a ‘snapstat’, a temperature- sensing switch which will be mounted to the blower duct just below the top plate of the stove. The snapstat automatically turns the fan on or off at approximately 109°F.

The rheostat provides a range of fan speed settings from OFF (which overrides the snapstat function) to high.

Kit Contents used with the RUVS40:

• Fan assembly with rheostat and snapstat

• wire tie

• control knob • retaining collar

These directions are oriented facing the rear of the stove. Position the fan underthe rear shroud as shown in Figure 10.

1.Remove the fan bracket. Remove the four sheet metal screws (A) to detach the bracket (AA) from the Rear Shroud. (Fig. 10)

2.Open the left side of Rear Shroud. (Fig. 10)

Remove the round head phillips screws (B) that secure the shroud to the side of the stove.

Remove the sheet metal screw (C) that fastens the switchbox to the rear shroud.

Remove the two sheet metal screws (D) that secure the inner and outer shroud together. Let the switchbox and wiring hang loosely.

3.Install the Control Switch. (Fig. 10)

Run the control switch (E) and wire up along the side between the inner and outer shrouds and through the slot at the side.

Attach the switch to the switch box with the retainer collar and control knob (F).

Secure the switch box assembly to the rear shroud with the single sheet metal screw (C).

4.Connect Snapstat leads.

Disconnect the snapstat module (G) from the leads inside the snapstat bracket (H).

Bend open the snapstat bracket (H). Use your fingers or needle nose pliers to remove the black plastic grommet from the bracket. Discard the bracket.

Insert the grommet and wires into the large hole at the bottom right corner of the inner shroud.

 

E

 

F

C

B

 

AA D

A

A

D

B

H

G

ST189

Fig. 10 Open the rear shroud and install fan control switch.

H

 

Pinch

G

grommet

to remove

ST190

 

 

ST191

Outer Shroud

Inner Shroud

Grommet

ST192

Fig. 11 Remove the snapstat and grommet from the bracket and insert the grommet into the inner shroud.

Feed the snapstat wire leads through the grommet into the stove interior. Connect the two wires to the two snapstat extension leads attached to the inner shroud.

10

Image 10
Contents Radiance Table of Contents Radiance Unvented Gas Heater RUVS40 SpecificationsFuel Type Safety Information Carbon Monoxide Poisoning MAY Lead to DeathGeneral Information Vent Free FeaturesQuick Installation Optional Fan Kit #2767 /FK26Provide For Adequate Ventilation Installation RequirementsFresh Air Requirements for Combustion and Ventilation Unusually Tight ConstructionVent options to provide additional air Freestanding Stove Minimum Clearances to Combustible MaterialsHearth Requirements Alcove ClearancesUnpacking the Radiance AssemblyHardware Bag Contents Remove the Front, Screen and LogsInstall the Control Switch. Fig Install Optional Fan, #2767/FK26Kit Contents used with the RUVS40 AA DAttach the fan assembly to the fan bracket Resecure the Rear Shroud panelsThermostat Connection optional Connect the Gas LineInstall the Logs Remove the valve cover plateComplete the Installation Replace the front panelYour First Fire OperationPilot and Burner Inspection For Your Safety Read Before Lighting No spark at Pilot when Ignitor is operated TroubleCondition Possible Cause Solution TroubleshootingOdor During Operation Glass Replacement Firebox Cleaning and InspectionCleaning Procedure Care of Cast IronRemove the combustor module Clean the combustor moduleCatalytic Combustor Replace the combustor moduleRadiance Vent Free Gas Heater RUVS40 RUVS40 #10-24 X 1/4 Phil. Pn Hd ScrewHow To Obtain Service Limited Three Year WarrantyLimited One Year Warranty Exclusions and LimitationsVermont Castings Majestic Products Company