Vermont Casting RUVS40 Firebox Cleaning and Inspection, Cleaning Procedure, Glass Replacement

Page 19

Maintenance

Your Radiance Vent Free heater will provide years of service with minimal upkeep. The following procedures will help ensure that your heater continues to perform safely and efficiently.

Firebox Cleaning and Inspection

Cleanliness is critical to correct operation of the heater. The log set, burner, valve controls and air circulation areas must all be kept free of dust and unobstructed by debris. Inspect these areas before each use and clean whenever accumulation is evident. Follow the simple procedure outlined below.

Frequent cleaning may be necessary in living environments subject to excessive carpet lint or pet hair. For example, if you live with a dog that sheds continuously, you will need to inspect the burner area frequently and clean it as often as the accumulation requires. In extreme conditions, it may be necessary to clean the burner and log set monthly or bi- weekly.

This appliance should be inspected and thor- oughly cleaned annually by a qualified gas techni- cian.

Cleaning Procedure

1.Turn the burner OFF and let the heater cool com- pletely before cleaning.

2.Lift the Front plate up and then swing the bottom out to disengage it from the heater shell. (Fig. 8, page 9)

3.Remove the screen or glass panel by releasing the two upper retainer latches (A). Lift the panel up and off of the firebox frame. (Fig. 34)

4.Carefully inspect the log set for damage. Contact your local dealer if any damage is evident. DO NOT

OPERATE THE HEATER WITH A DAMAGED OR LOOSE LOG SET.

Use a soft-bristled brush vacuum cleaner attach- ment to remove dust or debris from the log set, pilot and burner. Use care as the log set is fragile.

5.Inspect the catalytic combustor at the top of the firebox. Replace the combustor if any damage or deterioration is evident.

6.Replace the screen or glass panel and the front plate. DO NOT OPERATE THE HEATER WITH THE

SCREEN / GLASS PANEL OR FRONT PLATE REMOVED.

Vermont Castings Radiance

 

ST202/203

Fig. 34

Remove the screen or glass panel.

Glass Replacement

If so equipped, do not operate this appliance with the glass panel cracked, broken, or removed. Replace damaged glass only with Vermont Castings ceramic glass panel Part No. 160-1290. Follow the Cleaning Procedure instructions regarding parts removal.

Care of Cast Iron

An occasional dusting with a dry rag will help keep the painted surfaces looking new. Use high-temperature stove paints, available through your local dealer, to touch-up areas as needed. Clean areas to be painted with a wire brush and be sure to cover the log set, burner and valve assembly. Apply the paint sparingly; two light coats of paint will give better results than a single heavy coat.

Porcelain enamel surfaces should be cleaned with a soft, damp cloth. Do not use abrasive cleaning agents. If necessary, use only a cleaning agent formu- lated specifically for use on porcelain enamel surfaces.

WARNING

Turn the burner Pilot OFF before applying paint.

WARNING

Dust and debris accumulation can result in poor performance. Inspect the Valve compartment, burner parts and log set frequently and Clean these parts monthly or as often as accumulation warrants.

19

Image 19
Contents Radiance Table of Contents Radiance Unvented Gas Heater RUVS40 SpecificationsFuel Type Carbon Monoxide Poisoning MAY Lead to Death Safety InformationOptional Fan Kit #2767 /FK26 Vent Free FeaturesQuick Installation General InformationUnusually Tight Construction Installation RequirementsFresh Air Requirements for Combustion and Ventilation Provide For Adequate VentilationVent options to provide additional air Alcove Clearances Minimum Clearances to Combustible MaterialsHearth Requirements Freestanding StoveRemove the Front, Screen and Logs AssemblyHardware Bag Contents Unpacking the RadianceAA D Install Optional Fan, #2767/FK26Kit Contents used with the RUVS40 Install the Control Switch. FigResecure the Rear Shroud panels Attach the fan assembly to the fan bracketConnect the Gas Line Thermostat Connection optionalRemove the valve cover plate Install the LogsReplace the front panel Complete the InstallationYour First Fire OperationPilot and Burner Inspection For Your Safety Read Before Lighting Trouble No spark at Pilot when Ignitor is operatedCondition Possible Cause Solution TroubleshootingOdor During Operation Care of Cast Iron Firebox Cleaning and InspectionCleaning Procedure Glass ReplacementReplace the combustor module Clean the combustor moduleCatalytic Combustor Remove the combustor moduleRadiance Vent Free Gas Heater RUVS40 #10-24 X 1/4 Phil. Pn Hd Screw RUVS40Exclusions and Limitations Limited Three Year WarrantyLimited One Year Warranty How To Obtain ServiceVermont Castings Majestic Products Company