Vermont Casting manual Specifications, Radiance Unvented Gas Heater RUVS40, Fuel Type

Page 3

Vermont Castings Radiance

Specifications

Radiance Unvented Gas Heater RUVS40

Fuel Type:

NG

 

LP

 

 

Manifold Pressure; Min. / Max.: 1.7"/3.5"

5.4"/11.0"

Min. Inlet Supply Pressure for

 

 

 

adjustment::

5.0" W.C.

11.0" W.C.

Max. Inlet Supply Pressure for

 

 

 

adjustment:

8.0" W.C.

12.0" W.C.

Min. Output, BTU/hr:

26,000

 

26,000

Max. Output, BTU/hr:

35,000

 

35,000

Ignition :

 

Piezo

Firebox Weight / shipping:

175 lbs.

This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes.

This appliance is to be used only with the type of gas specified on the rating plate which is attached to the rear panel. This appliance is not convertible for use with other gases.

Available Optional Accessories:

Fan Kit #2767 / FK26

Glass Panel / Catalyst Kit RGDCK

*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer.

Dimensions

29C\v"

(755.7mm)

28Z\v"

(717.6mm)

R A D I A N C E

31"

(787.4mm)

Drawing Not to Scale

6Z\x"

Supply Inlet

(165.1mm)

 

11"

(279.4mm)

18C\," (466.7mm)

ST181

Fig. 1 Radiance Vent Free dimensions.

3

Image 3
Contents Radiance Table of Contents Specifications Radiance Unvented Gas Heater RUVS40Fuel Type Carbon Monoxide Poisoning MAY Lead to Death Safety InformationOptional Fan Kit #2767 /FK26 Vent Free FeaturesQuick Installation General InformationUnusually Tight Construction Installation RequirementsFresh Air Requirements for Combustion and Ventilation Provide For Adequate VentilationVent options to provide additional air Alcove Clearances Minimum Clearances to Combustible MaterialsHearth Requirements Freestanding StoveRemove the Front, Screen and Logs AssemblyHardware Bag Contents Unpacking the RadianceAA D Install Optional Fan, #2767/FK26Kit Contents used with the RUVS40 Install the Control Switch. FigResecure the Rear Shroud panels Attach the fan assembly to the fan bracketConnect the Gas Line Thermostat Connection optionalRemove the valve cover plate Install the LogsReplace the front panel Complete the InstallationOperation Your First FirePilot and Burner Inspection For Your Safety Read Before Lighting Trouble No spark at Pilot when Ignitor is operatedTroubleshooting Condition Possible Cause SolutionOdor During Operation Care of Cast Iron Firebox Cleaning and InspectionCleaning Procedure Glass ReplacementReplace the combustor module Clean the combustor moduleCatalytic Combustor Remove the combustor moduleRadiance Vent Free Gas Heater RUVS40 #10-24 X 1/4 Phil. Pn Hd Screw RUVS40Exclusions and Limitations Limited Three Year WarrantyLimited One Year Warranty How To Obtain ServiceVermont Castings Majestic Products Company