5.Resecure the Rear Shroud panels.
•Reinstall and tighten the two sheet metal screws (D, Fig. 10) that secure the inner and outer shrouds together.
•Secure the upper corner of the shroud and switch box to the side of the stove using a 1/4
Finally, replace the lower screw.
6.Attach the fan assembly to the bracket removed earlier. Remove the sheet metal screws that secure the finger guards at each end of the fan housing. Use these screws to attach the fan to the bracket. (Fig. 12)
•Position the fan assembly so that the ducts slide between the inner and outer shroud. The inner shroud should engage with the two slots in the ends of the bracket so that bracket and shroud are interlocked. (Fig.14) Secure the bracket with the four sheet metal screws previously removed.
Fan Bracket
ST193 | Finger Guard |
|
Fig. 12 Attach the fan assembly to the fan bracket.
Outer | Slot |
Shroud |
|
| {Inner Shroud} |
| Slot |
| ST194 |
Fig. 13 Position the fan to engage the inner shroud with the fan bracket slots and secure with sheet metal screws.
Vermont Castings Radiance
7.Install snapstat. (Fig. 13) Looking through the stove front, locate the snapstat mounting screws on the side of the left air duct under the top plate. Remove the front screw (A), but only loosen the rear screw. Slip the snapstat under the rear screw, replace the front screw, and tighten both.
•Detach the extension wire from the retainer clip at the rear. Connect the female flag connectors (B) of the snapstat extension to the snapstat module. Confirm that the wires are running to the back and away from the top of the stove.
8.Plug the power cord into a standard grounded 110- volt household outlet. If the fan control knob is not turned
to the OFF position, the fan will turn on when the tem- perature at the snapstat reaches approximately 109°F.
Left Air Duct | Snapstat |
| |
| B |
| A |
| ST195 |
Fig. 14 Install the snapstat and connect the extension wire terminals. View is with top removed, however, access is available through the grate opening in the top plate.
MOTORDisconnect power before servicing.
BLK | BLK | BLK SNAPSTAT |
|
| |
WHT | BLK | WHT |
GRN | RHEOSTAT | |
|
| ON/OFF |
| POWER |
|
ST196
Fig. 15 2767 / FK26 Fan Wiring Diagram
WARNING
The optional fan kit is equipped with a three- prong (grounding) plug for your protection against shock hazard and should be plugged directly into
aproperly grounded
plug.
11