Vermont Casting RUVS40 manual Install the Logs, Remove the valve cover plate

Page 13

ADJPILOT

H

I

ST172

Fig. 17 Remove the valve cover plate.

ADJPILOT

ON

O H

I

OFF

ST173

Fig. 18 Flexible gas line connection.

Pilot

On/Off

 

 

 

Control

 

 

 

Adjustment

Knob

 

 

 

Screw

 

 

Regulator

 

 

 

PILOT ADJ

 

 

 

 

TPTH

 

ON

L

O H

 

 

 

I

TP

PILOT

 

 

 

 

 

 

 

 

OFF

 

 

 

TH

 

 

 

 

Pressure Tap

Piezo

 

 

 

 

Ignitor

 

HV100

Fig. 19 The gas control valve includes a captured screw- type pressure test point. A pressure test point upstream from the control valve is not required.

Vermont Castings Radiance

Install the Logs

Install the logs in sequence as shown below. The log set includes six sections: the rear log, left and right middle logs, left and right ember logs, and an upper log. There is also a bag of lava rocks which simulate charcoal and embers.

1.Install the rear log (#1, Fig. 20) by engaging holes on its bottom surface with pins on the sheet-metal shelf at the back of the firebox.

2.Install the left and right middle logs (#2 and #3, Fig. 20) by engaging holes on their bottom surfaces with pins on the burner brackets.

2

1

3

 

 

Brackets

 

 

 

ST142

Fig. 20

Install rear and middle logs.

 

3.Push the burner assembly fully to the rear. There should be a gap of about 13/16” between the front of the burner and the inside front wall of the firebox. Place the two front ember log sections (#4 and 5, Fig. 21) in the slot at the front of the firebox, just in front of the burner.

 

5

 

4

 

ST143

Fig. 21

Install the front ember logs.

 

13

Image 13
Contents Radiance Table of Contents Radiance Unvented Gas Heater RUVS40 SpecificationsFuel Type Carbon Monoxide Poisoning MAY Lead to Death Safety InformationQuick Installation Vent Free FeaturesGeneral Information Optional Fan Kit #2767 /FK26Fresh Air Requirements for Combustion and Ventilation Installation RequirementsProvide For Adequate Ventilation Unusually Tight ConstructionVent options to provide additional air Hearth Requirements Minimum Clearances to Combustible MaterialsFreestanding Stove Alcove ClearancesHardware Bag Contents AssemblyUnpacking the Radiance Remove the Front, Screen and LogsKit Contents used with the RUVS40 Install Optional Fan, #2767/FK26Install the Control Switch. Fig AA DResecure the Rear Shroud panels Attach the fan assembly to the fan bracketConnect the Gas Line Thermostat Connection optionalRemove the valve cover plate Install the LogsReplace the front panel Complete the InstallationYour First Fire OperationPilot and Burner Inspection For Your Safety Read Before Lighting Trouble No spark at Pilot when Ignitor is operatedCondition Possible Cause Solution TroubleshootingOdor During Operation Cleaning Procedure Firebox Cleaning and InspectionGlass Replacement Care of Cast IronCatalytic Combustor Clean the combustor moduleRemove the combustor module Replace the combustor moduleRadiance Vent Free Gas Heater RUVS40 #10-24 X 1/4 Phil. Pn Hd Screw RUVS40Limited One Year Warranty Limited Three Year WarrantyHow To Obtain Service Exclusions and LimitationsVermont Castings Majestic Products Company