Vermont Casting MSY-D36NA, MSZ-D36NA EMERGENCY/TEST Operation, Minute Time Delay Operation

Page 18

8-9. EMERGENCY/TEST OPERATION

In case of test run operation or emergency operation, use EMERGENCY OPERATION switch on the front of the indoor unit. Emergency operation is available when the remote controller is missing, has failed or the batteries of the remote controller run down. The unit will start and OPERATION INDICATOR lamp will light.

The first 30 minutes of operation is the test run operation. This operation is for servicing. The Indoor fan speed runs at High speed and the system is in continuous operation (with thermostat ON).

After 30 minutes of test run operation the system shifts to EMERGENCY COOL / HEAT MODE with a set temperature of 75 °F (24 °C). The fan speed shifts to Med.

All protective operations such as the coil frost prevention works even in emergency operation.

In the test run or emergency operation, the horizontal vane operates in VANE AUTO ( ) mode.

Emergency operation continues until EMERGENCY OPERATION switch is pressed once or twice or the unit receives any signal from the remote controller. In case of latter normal operation will start.

NOTE : Do not press EMERGENCY OPERATION switch during normal operation.

E.O.

SW

E.O.

Operation mode

COOL

HEAT

(MUZ)

 

 

Set temperature

75 °F (24 °C)

75 °F (24 °C)

Fan speed

Med.

Med.

Horizontal vane

Auto

Auto

The operation mode is indicated by the Operation Indicator lamp as following

Operation Indicator lamp (MSZ type)

EMERGENCY COOL

EMERGENCY OPERATION switch

SW

Lighted

Not lighted

 

EMERGENCY HEAT

 

STOP

(MSY type)

EMERGENCY COOL

STOP

8-10. 3-MINUTE TIME DELAY OPERATION

When the system turns OFF, compressor will not restart for 3 minutes as 3-minute time delay function operates to protect compressor from overload.

8-11. CHANGING TEMPERATURE INDICATION (°F /°C)

The preset unit is °F.

°F→°C : Press RESET button while the

temperature buttons are pressed.

• °C→°F : Press RESET button or remove the batteries .

Press RESET button gently using a thin stick.

18

Image 18
Contents MSZ-D30NA MSZ-D36NA MSY-D30NA MSY-D36NA Page Technical Changes Accessories Part Names and FunctionsSpecification Operating Range Outlet AIR Speed and Coverage RangeOutlines and Dimensions MSZ-D36NA MSY-D30NA MSY-D36NAWiring Diagram Refrigerant System Diagram UnitinchHow to modify the remote controller P.C. board Service FunctionsTimer Short Mode P.C. Board Modification for Individual OperationAuto Restart Function OperationOperation Indicator lamp Microprocessor ControlFAN Operation MSY Cool OperationHeat Operation MSZ Feel Control Operation MSYAuto Change Over ··· Auto Mode Operation MSZ Mode selectionFuzzy control Auto Vane Operation Vertical vane 3 4 Swing 5Program Timer Minute Time Delay Operation Changing Temperature Indication F /CEMERGENCY/TEST Operation Troubleshooting procedure TroubleshootingBefore troubleshooting, check the following How to replace batteriesFailure Mode Recall Function OFFIndoor unit failure mode table Eration IndicaInstruction of Troubleshooting StartTroubleshooting Check Table Lighted Blinking Not lightedTrouble Criterion of Main Parts Troubleshooting Flow Check of indoor fan motorCheck of remote controller and receiver P.C. board Indoor electronic control P.C. board How to check miswiring and serial signal error Electromagnetic noise enters into TV sets or radios Test Point Diagram and Voltage Power monitor receiver P.C. boardSW P.C. board Removing the panel Disassembly InstructionsBoard, the power monitor receiver P.C. board and the SW Removing the electrical box, the electronic control P.CRemoving the nozzle assembly Removing the vertical vane motorRemoving the horizontal vane motor Removing the line flow fan and the indoor fan motor Page Page New publication, effective Feb Distributed in Feb . No. OBH501Made in Japan