2. Indoor unit failure mode table
Left lamp of OP- | Abnormal point |
|
|
| |
ERATION INDICA- | Condition |
| Correspondence | ||
(Failure mode) |
| ||||
TOR lamp |
|
|
| ||
|
|
|
| ||
Not lighted | Normal | — |
| — | |
Room temperature | The room temperature thermistor short or open | Refer to the characteristics of the room temperature | |||
circuit is detected every 8 seconds during op- | |||||
thermistor | eration. | thermistor | |||
|
|
|
| ||
Indoor coil thermis- | The indoor coil thermistor short or open circuit | Refer to the characteristics of the main indoor coil | |||
tor | is detected every 8 seconds during operation. | thermistor, the sub indoor coil thermistor | |||
Serial signal | The serial signal from outdoor unit is not re- | Refer to | "How to check miswiring and serial | ||
ceived for a maximum of 6 minutes. | signal error". |
| |||
|
| ||||
| The rotational frequency feedback signal is |
|
| ||
Indoor fan motor | not emit during the 12 seconds the indoor fan | Refer to | "Check of indoor fan motor". | ||
| operation. |
|
| ||
|
|
|
| ||
Indoor control | It cannot properly read data in the nonvolatile |
|
| ||
memory of the indoor electronic control P.C. | Replace the indoor electronic control P.C. board. | ||||
system | |||||
board. |
|
| |||
|
|
|
|
NOTE : Blinking patterns of this mode differ from the ones of Troubleshooting check table
21