Vermont Casting MSZ-D30NA service manual Outlines and Dimensions, MSZ-D36NA MSY-D30NA MSY-D36NA

Page 7

4 OUTLINES AND DIMENSIONS

MSZ-D30NA

Unit : inch

MSZ-D36NA

 

MSY-D30NA

 

MSY-D36NA

 

 

2-11/16

 

Indoor unit

4-11/16

45-1/2

 

 

 

 

1-7/8

 

 

 

 

2-3/16

 

20-7/8

17-11/16

5-3/8

 

11-5/8

1/4

Wall hole ø3

 

46-1/16

Air in

 

Installation plate

 

 

 

 

 

Piping

14-3/8

1/8 1-7/8 11-5/8 7/8

2-15/16

33-11/16

9-1/2

Air out

2-5/163/4

14-3/8

Wireless remote controller

 

2-1/2

2-15/16

Drain hose

2-5/8

 

5-7/8

 

 

 

 

Piping

Insulation

Liquid line

ø3/8 19-11/16

ø1-1/4 O.D

 

(Flared connection ø3/8)

ø9/16 I.D

Gas line

ø5/8 16-7/8

ø1-15/16 O.D

 

(Joint connection ø5/8)

ø1-1/4 I.D

Joint

ø5/8

ø1-15/16 O.D

 

(Flared connection ø5/8)

ø1-1/4 I.D

Drain hose

Inslation ø1-1/8 Connected part ø9/16 O.D

 

3/8 or more

Required Space (Indoor Unit)

4-11/16 or more

8-11/16 or more

 

2-13/16 or more 14-1/2 or more

4-3/16 or more

9-3/8 or more

In case of left,left back,

2-3/16 ormore

or left under piping (using spacer) 5-1/8 or more

7

Image 7
Contents MSZ-D30NA MSZ-D36NA MSY-D30NA MSY-D36NA Page Technical Changes Part Names and Functions AccessoriesSpecification Outlet AIR Speed and Coverage Range Operating RangeMSZ-D36NA MSY-D30NA MSY-D36NA Outlines and DimensionsWiring Diagram Unitinch Refrigerant System DiagramP.C. Board Modification for Individual Operation Service FunctionsTimer Short Mode How to modify the remote controller P.C. boardOperation Auto Restart FunctionMicroprocessor Control Operation Indicator lampFeel Control Operation MSY Cool OperationHeat Operation MSZ FAN Operation MSYMode selection Auto Change Over ··· Auto Mode Operation MSZFuzzy control Auto Vane Operation 3 4 Swing 5 Vertical vaneProgram Timer Changing Temperature Indication F /C Minute Time Delay OperationEMERGENCY/TEST Operation How to replace batteries TroubleshootingBefore troubleshooting, check the following Troubleshooting procedureOFF Failure Mode Recall FunctionEration Indica Indoor unit failure mode tableStart Instruction of TroubleshootingLighted Blinking Not lighted Troubleshooting Check TableTrouble Criterion of Main Parts Check of indoor fan motor Troubleshooting FlowCheck of remote controller and receiver P.C. board Indoor electronic control P.C. board How to check miswiring and serial signal error Electromagnetic noise enters into TV sets or radios Power monitor receiver P.C. board Test Point Diagram and VoltageSW P.C. board Removing the electrical box, the electronic control P.C Disassembly InstructionsBoard, the power monitor receiver P.C. board and the SW Removing the panelRemoving the vertical vane motor Removing the nozzle assemblyRemoving the horizontal vane motor Removing the line flow fan and the indoor fan motor Page Page Distributed in Feb . No. OBH501 New publication, effective FebMade in Japan