Vermont Casting MSZ-D30NA, MSZ-D36NA Electromagnetic noise enters into TV sets or radios

Page 29

E Electromagnetic noise enters into TV sets or radios

Is the unit grounded?

Yes

Is the distance between the antennas and the indoor unit within 9.91 ft., or is the distance between the antennas and the outdoor unit within 9.91 ft.?

No

Is the distance between the TV sets or radios and the indoor unit within 3.28 ft., or is the distance between the TV sets or radios and the outdoor unit within 9.91 ft.?

No

No

Yes

Yes

Ground the unit.

Extend the distance between the antennas and the indoor unit, and/or the antennas and the

outdoor unit.

Extend the distance between the TV sets and/or radios and the indoor unit, or the TV sets or

radios and the outdoor unit.

Are the antennas damaged? Is the coaxial cable damaged?

Is there any poor contact in the anten- Yes na wiring?

No

Replace or repair the antenna. Replace or repair the coaxial cable.

Is the indoor/outdoor connecting wire of

 

the air conditioner and the wiring of the

Yes

antennas close?

 

No

 

 

 

 

 

 

Extend the distance between the indoor/outdoor connecting wire of the air conditioner and the wir-

ing of the antennas.

Even if all of the above conditions are fulfilled, the electromagnetic noise may enter, depending on the electric field strength or the installation condition (combination of specific conditions such as antennas or wiring).

Check the followings before asking for service.

1.Devices affected by the electromagnetic noise TV sets, radios (FM/AM broadcast, shortwave)

2.Channel, frequency, broadcast station affected by the electromagnetic noise

3.Channel, frequency, broadcast station unaffected by the electromagnetic noise

4.Layout of ;

indoor/outdoor unit of the air conditioner, indoor/outdoor wiring, grounding wire, antennas, wiring from antennas, receiver

5.Electric field intensity of the broadcast station affected by the electromagnetic noise

6.Presence or absence of amplifier such as booster

7.Operation condition of air conditioner when the electromagnetic noise enters in

1)Turn OFF the power supply once, and then turn ON the power supply. In this situation, check for the electromagnetic noise.

2)Within 3 minutes after turning ON the power supply, press OPERATE/STOP (ON/OFF) button on the remote controller for power ON, and check for the electromagnetic noise.

3)After a short time (3 minutes later after turning ON), the outdoor unit starts running. During operation, check for the electromagnetic noise.

4)Press OPERATE/STOP (ON/OFF) button on the remote controller for power OFF, when the outdoor unit stops but the indoor/outdoor communication still runs on. In this situation, check for the electromagnetic noise.

29

Image 29
Contents MSZ-D30NA MSZ-D36NA MSY-D30NA MSY-D36NA Page Technical Changes Part Names and Functions AccessoriesSpecification Outlet AIR Speed and Coverage Range Operating RangeMSZ-D36NA MSY-D30NA MSY-D36NA Outlines and DimensionsWiring Diagram Unitinch Refrigerant System DiagramTimer Short Mode Service FunctionsHow to modify the remote controller P.C. board P.C. Board Modification for Individual OperationOperation Auto Restart FunctionMicroprocessor Control Operation Indicator lampHeat Operation MSZ Cool OperationFAN Operation MSY Feel Control Operation MSYFuzzy control Auto Change Over ··· Auto Mode Operation MSZMode selection Auto Vane Operation 3 4 Swing 5 Vertical vaneProgram Timer EMERGENCY/TEST Operation Minute Time Delay OperationChanging Temperature Indication F /C Before troubleshooting, check the following TroubleshootingTroubleshooting procedure How to replace batteriesOFF Failure Mode Recall FunctionEration Indica Indoor unit failure mode tableStart Instruction of TroubleshootingLighted Blinking Not lighted Troubleshooting Check TableTrouble Criterion of Main Parts Check of indoor fan motor Troubleshooting FlowCheck of remote controller and receiver P.C. board Indoor electronic control P.C. board How to check miswiring and serial signal error Electromagnetic noise enters into TV sets or radios SW P.C. board Test Point Diagram and VoltagePower monitor receiver P.C. board Board, the power monitor receiver P.C. board and the SW Disassembly InstructionsRemoving the panel Removing the electrical box, the electronic control P.CRemoving the horizontal vane motor Removing the nozzle assemblyRemoving the vertical vane motor Removing the line flow fan and the indoor fan motor Page Page Made in Japan New publication, effective FebDistributed in Feb . No. OBH501