3-1. OPERATING RANGE
(1) POWER SUPPLY
| Rated voltage |
| Guaranteed Voltage | |||
|
|
|
|
|
|
|
| 208/230 V | Min.187 V 208 V 230 V Max.253 V | ||||
Indoor unit | 1 phase |
|
|
|
|
|
|
|
|
|
| ||
| 60 Hz |
|
|
|
|
|
|
|
|
|
|
|
|
(2) OPERATION
Mode | Condition |
|
| Intake air temperature (°F) |
|
| |
Indoor |
|
| Outdoor | ||||
|
| DB |
| WB | DB |
| WB |
| Standard temperature | 80 |
| 67 | 95 |
| — |
Cooling | Maximum temperature | 90 |
| 73 | 115 |
| — |
Minimum temperature | 67 |
| 57 | 14 |
| — | |
|
|
| |||||
| Maximum humidity | 78 | % |
|
| — | |
Heating | Standard temperature | 70 |
| 60 | 47 |
| 43 |
Maximum temperature | 80 |
| 67 | 75 |
| 65 | |
| Minimum temperature | 70 |
| 60 | 14 |
| 13 |
3-2. OUTLET AIR SPEED AND COVERAGE RANGE
Model | Mode | Function | Airlow | Air speed | Coverage | |
(CFM) | (ft./sec.) | range (ft.) | ||||
|
|
| ||||
HEAT | Dry | 848 | 23.6 | 45.0 | ||
|
|
|
|
| ||
| Dry | 848 | 23.6 | 45.0 | ||
COOL |
|
|
|
| ||
Wet | 763 | 21.3 | 40.7 | |||
| ||||||
|
| |||||
|
|
|
|
| ||
|
|
|
|
|
|
The air coverage range is the figure up to the position where the air speed is 1 ft./sec., when air is blown out horizon- tally from the unit properly at the High speed position.
The coverage range should be used only as a general guideline since it var- ies according to the size of the room and furniture arranged inside the room.