Defiant 1610
Distance from the Center of the Flue Collar to the Wall for 6” Connections ONLY
The information on this page is helpful in planning stove placement, particularly in those installations with chimneys that pass through the ceiling. However, this is not a clearance chart. Final stove clearances must adhere to the guidelines in the clearance chart on Page 14 for 6” connections.
Defiant With Flue Collar Heat Shield Only
Unprotected Surfaces |
|
| Protected Surfaces | ||||
Parallel Installations | Corner | Parallel Installations |
| Corner | |||
| |||||||
Installations |
| Installations | |||||
|
|
|
|
|
| ||
Side (A) | Rear (B) | Corner (C) | Side (D) |
| Rear (E) |
| Corner (F) |
|
| ||||||
|
|
|
|
|
|
|
|
41³⁄₄” | 30³⁄₈” | 37” | 28³⁄₄” |
| 25³⁄₈” |
| 30” |
(1060 mm) | (772 mm) | (440 mm) | (730 mm) |
| (645 mm) |
| (762 mm) |
|
|
|
|
|
|
|
|
Defiant With Flue Collar Heat Shield and Shielded Connector:
Side (A)
41³⁄₄”
(1060 mm)
Rear (B)
17³⁄₈”
(441 mm)
Corner (C)
37”
(940 mm)
Side (D)
28³⁄₄”
(730 mm)
Rear (E)
25³⁄₈”
(660 mm)
Corner (F)
30”
(762 mm)
Defiant With Flue Collar Heat Shield and
|
|
|
|
|
|
|
| Side (A) | Rear (B) | Corner (C) | Side (D) | Rear (E) | Corner (F) |
|
|
|
|
|
|
|
| 41³⁄₄” | 22³⁄₈” | 26” | 25³⁄₄” | 21³⁄₈” | 27” |
| (1060 mm) | (568 mm) | (660 mm) | (654 mm) | (543 mm) | (686 mm) |
|
|
|
|
|
|
|
A
*
BC
D
*
EF
*This distance, from the center of the flue collar to the front edge of the hearth, is the same for all installations on this page: 35” (889 mm) in the United States and 37” (340 mm) in Canada.
18 | 30002850 |