Vermont Casting 1610 installation instructions Operation, Defiant Controls, Fan Kit Installation

Page 22

Defiant 1610 Non-Catalytic Woodburning Stove

Fan Kit Installation

1.Attach the fan assembly at the bottom edge of the in- ner back with two (2) 1/4-20 x 3/4” hex head screws.

2.Attach snapstat to the mounting holes on the un- derside of the bottom with two (2) 1/4-20 pan head screws.

3.Attach the rheostat holder (provided with the stove) under the right front wing of the bottom heat shield with two (2) #10 sheet metal screws.

4.Attach the rheostat to its holder by inserting the rheo- stat control shaft through the holder hole. Install the retaining ring and rheostat knob onto the shaft.

5.Secure the rheostat cable to the underside of the bottom heat shield using the wire tie provided and the hole at the right rear edge of the heat shield.

6.Fan will not operate until stove reaches approximate- ly 109°F.

Hole for Wire

Tie to Secure

Cable

Rheostat

Knob

Rheostat

Holder

Rheostat

Snapstat

Screws

 

 

 

ST848

Fig. 26 Fan installation (Kit # 2767).

Operation

The Defiant Controls

Two controls regulate the performance of the Defiant: a primary air control supplies oxygen for the fire, and a damper directs air flow within the stove to activate and deactivate the catalytic combustor. (Fig. 27)

Symbols cast into the stove are reminders of the correct directions for using the controls. The words ‘Left’ and ‘right’ in these directions are facing the stove.

Damper Griddle Handle

Door Handle

Handle

 

 

 

 

 

 

 

 

 

Air

Control

Lever

Andiron

Door Handle Holder (Behind Leg)

Ash Door Handle

ST541

Fig. 27 The Defiant’s controls are conveniently located and easy to operate.

A Single Air Control Regulates

Heat Output and Burn Time

The primary air control lever, on the right side of the stove, controls the amount of incoming air for starting, maintaining, and reviving a fire.

More air entering the stove makes the fire burn hotter and faster, while less air prolongs the burn at a lower heat output level. (Fig. 28)

For the greatest air supply and maximum heat output (but the shortest burn time), move the lever toward the front of the stove. For a fire that will last longer with

less heat, move the lever toward the rear of the stove.

Air Control Positions

D E F I A N T

� � � � � � �

Low Heat

Range

 

D E F I A N T

Medium Heat

� � � � � � �

Range

 

High Heat

� � � � � � �

 

D E F I A N T

Range

 

ST542

Fig. 28 The handle also may be positioned anywhere be- tween the two extremes for different heat levels.

22

30002850

Image 22
Contents Defiant Welcome Save These Instructions for Future ReferenceInstallation Accessories Table of ContentsStory of the Defiant Specifications Defiant, ModelOutside Air InstallationChimney Height Prefabricated Chimneys What Kind of Chimney to UseMasonry Chimneys Chimney SizeSecuring the Single-wall Connector to a Masonry Chimney Chimney Connector GuidelinesSingle-wall Chimney Connectors Freestanding InstallationsFireplace Installations Above the FireplaceThrough the Fireplace Wall Pass-ThroughsFloor Protection An approved wall pass-through for CanadaFloor Protection for Fireplace Installation Keep the Stove a Safe Distance From Surrounding MaterialsWall Shields Safe Ways to Reduce ClearancesFireplace and Mantel Trim Shields Fireplace and Mantel Trim Clearances Defiant NC Clearance Chart for 6 Connections only Stove Clearance Unprotected Surfaces Protected Surfaces1Defiant NC Clearance Chart for 8 Connections only Stove Clearance1 Unprotected Surfaces Protected SurfacesDefiant NC Clearance Diagrams Unprotected Surfaces Protected SurfacesRefer to Important 1220 mm Note on This Installations Defiant With Flue Collar Heat Shield Only34³⁄₈ Install Stove Legs AssemblySet Up Your Stove Install the Bottom Heat ShieldReverse the Flue Collar If necessary Install the Optional Ash Door Heat ShieldAdjust the Leg Levellers Attach the Damper HandleDefiant Controls Fan Kit InstallationOperation Single Air Control Regulates Heat Output and Burn TimeDamper Directs Air Flow Within the Stove Two Ways to Add FuelAndirons Help Protect the Glass Use the Air Control Settings that Work Best for YouInfra-Red Reflective Glass Panels For Clear Fire Viewing Burn Only High-Quality WoodConditioning Your Stove Defiant Control SettingsStarting and Maintaining a Wood Fire Refuel While the Embers Are Still Hot Add larger pieces of wood as the fire begins to burnAsh Disposal Indoor/Outdoor Location Draft ManagementSteel Chimney Flue SizingCreosote Draft TestingSingle Venting FuelConclusion Maintenance Tighten the Damper Handle as Needed Adjust the Damper as NeededHow to Adjust the Door Latches Replace the Stove Gaskets as NeededChimney System All Gasketed Construction GasketsMaintenance Schedule Stove Chimney ConnectorDefiant Woodburning Stove Defiant Woodburning Stove Model Shell Enamel Parts Defiant Model Defiant 1610 Non-Catalytic Woodburning Stove Limited Lifetime Warranty CFM Corporation