Vermont Casting 1610 Install the Optional Ash Door Heat Shield, Adjust the Leg Levellers

Page 21

Install the Optional Ash Door Heat Shield

Many installations will require the use of the supplied ash door heat shield. Refer to the “Floor Protection” sections starting on Page 10 to determine if your instal- lation requires the use of the ash door heat shield.

1.Remove the two Phillips pan head screws from the ash door.

2.Insert the screws through the ash door heat shield (from the painted side), place the 5/16” spacers over the screws, and carefully thread them back into the original holes. (Fig. 23) The curved lip should be upward, under the ashlip of the stove.

3.Tighten securely.

Spacers

ST538

Fig. 23 Install the ashdoor heat shield.

Adjust the Leg Levellers

Lift the stove slightly so there is no weight on the leg while making the adjustment.

Reverse the Flue Collar (If necessary)

Reverse the flue collar by removing the two screws that attach it to the back of the stove. Be sure the gasket around the flue collar opening is in position when you screw the collar back onto the stove.

Defiant 1610 Non-Catalytic Woodburning Stove

Attach the Damper Handle

Use the 1/4” -20 x 3” screw to attach the damper handle to the damper stub on the left side.

Attach the Primary Air Thermostat Handle

The primary air thermostat handle is the smaller of the two black handles. Secure the handle to the stub on the right side of the stove with an 8-32 x 2” slot head machine screw. (Fig. 24)

Assemble the Removable Insert Handle

The ceramic removable insert handle opens and closes the front doors. Remove after each use, and store it in the handle holder behind the right front leg. Assemble the handle by passing the 3³⁄₈" screw through the ceramic shaft and into the bright metal nub. (Fig. 25) Tighten carefully until snug.

ST539

Fig. 24 Attach the thermostat handle.

ST540

Fig. 25 Assemble the front door handle.

30002850

21

Image 21
Contents Defiant Save These Instructions for Future Reference WelcomeTable of Contents Installation AccessoriesStory of the Defiant Defiant, Model SpecificationsInstallation Outside AirChimney Height Masonry Chimneys What Kind of Chimney to UsePrefabricated Chimneys Chimney SizeSingle-wall Chimney Connectors Chimney Connector GuidelinesSecuring the Single-wall Connector to a Masonry Chimney Freestanding InstallationsAbove the Fireplace Fireplace InstallationsWall Pass-Throughs Through the FireplaceAn approved wall pass-through for Canada Floor ProtectionKeep the Stove a Safe Distance From Surrounding Materials Floor Protection for Fireplace InstallationSafe Ways to Reduce Clearances Wall ShieldsFireplace and Mantel Trim Shields Fireplace and Mantel Trim Clearances Stove Clearance Unprotected Surfaces Protected Surfaces1 Defiant NC Clearance Chart for 6 Connections onlyStove Clearance1 Unprotected Surfaces Protected Surfaces Defiant NC Clearance Chart for 8 Connections onlyUnprotected Surfaces Protected Surfaces Defiant NC Clearance DiagramsRefer to Important 1220 mm Note on This Defiant With Flue Collar Heat Shield Only Installations34³⁄₈ Set Up Your Stove AssemblyInstall Stove Legs Install the Bottom Heat ShieldAdjust the Leg Levellers Install the Optional Ash Door Heat ShieldReverse the Flue Collar If necessary Attach the Damper HandleOperation Fan Kit InstallationDefiant Controls Single Air Control Regulates Heat Output and Burn TimeTwo Ways to Add Fuel Damper Directs Air Flow Within the StoveInfra-Red Reflective Glass Panels For Clear Fire Viewing Use the Air Control Settings that Work Best for YouAndirons Help Protect the Glass Burn Only High-Quality WoodDefiant Control Settings Conditioning Your StoveStarting and Maintaining a Wood Fire Add larger pieces of wood as the fire begins to burn Refuel While the Embers Are Still HotAsh Disposal Steel Chimney Draft ManagementIndoor/Outdoor Location Flue SizingSingle Venting Draft TestingCreosote FuelConclusion Maintenance How to Adjust the Door Latches Adjust the Damper as NeededTighten the Damper Handle as Needed Replace the Stove Gaskets as NeededAll Gasketed Construction Gaskets Chimney SystemChimney Connector Maintenance Schedule StoveDefiant Woodburning Stove Defiant Woodburning Stove Model Shell Enamel Parts Defiant Model Defiant 1610 Non-Catalytic Woodburning Stove Limited Lifetime Warranty CFM Corporation