INSTALLATION
Continued
2.If using blower, install and properly ground GA3555,
3.Install gas piping into fireplace location. This installation includes an approved flexible gas line (if allowed by local codes) after the equip- ment shutoff valve. The flexible gas line must be the last item installed on the gas piping. See Installing Gas Piping to Fireplace Location, column 2.
4.Carefully set fireplace in front of rough opening with back of fireplace inside wall opening.
5.Plug electrical cord into electrical outlet installed in step 2.
6.Carefully insert fireplace into rough opening.
7.Attach flexible gas line to gas supply. See Con- necting Fireplace to Gas Supply, page 14.
8.Attach fireplace to wall studs using nails or wood screws through holes in nailing flange (see Figure 15).
9.Check all gas connections for leaks. See Checking Gas Connections, page 15.
10.Install trim after final finishing and/or painting of wall (see Figure 7, page 9).
Nails or
Wood
Screws
Nailing
Flanges
Figure 15 - Attaching Fireplace to Wall
Studs
Mantel Clearances for
If your installation does not meet the below mini- mum clearances, you must:
•raise the mantel to an acceptable height,
OR
•remove the mantel.
10" |
| Mantel Shelf | |||
|
|
| |||
8" |
|
|
|
| |
6" |
|
|
|
| |
2 | 1 | /2" |
|
|
|
|
|
|
| ||
Minimum Non- |
|
|
|
|
|
Combustible |
|
|
|
|
|
Material |
| 13" | 16" | 19" | 21" |
|
| ||||
|
|
| Note: All Vertical | ||
|
|
| measurements are | ||
|
|
| from top of fireplace | ||
|
|
| opening to bottom | ||
|
|
| of mantel shelf. | ||
Figure 16 - Minimum Mantel Clearances | |||||
for | |||||
INSTALLING GAS PIPING TO | |||||
FIREPLACE LOCATION |
| ||||
WARNING: This appliance | |||||
requires a 1/2" NPT (National | |||||
Pipe Thread) inlet connection to | |||||
the pressure regulator. | |||||
WARNING: A | qualified | ||||
service person must connect | |||||
fireplace to gas supply. Follow | |||||
all local codes. |
|
|
| ||
CAUTION: Never connect | |||||
propane/LP fireplace directly | |||||
to the propane/LP supply. This | |||||
heater requires an external regu- | |||||
lator (not supplied). | Install the | ||||
external regulator between the | |||||
heater and propane/LP supply. | |||||
WARNING: Never connect | |||||
natural gas fireplace to private | |||||
gas is commonly known as | |||||
wellhead gas. |
|
|
|
12 | www.desatech.com |