OPERATING FIREPLACE
Continued
7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.
Note: If pilot goes out, repeat steps 3 through 7. This fireplace has a safety inter- lock system. Wait one (1) minute for system to reset before lighting pilot again.
•If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.
8.Turn control knob counterclockwise to desired heating level. The burn- ers should light. Set control knob to any heat level between HI and LO.
CAUTION: Do not try to ad- just heating levels by using the equipment shutoff valve.
Ignitor Electrode | Pilot Burner |
Figure 29 - Pilot
TO TURN OFF GAS |
|
TO APPLIANCE |
|
Shutting Off Fireplace |
|
Turn control knob clockwise | to the |
OFF position. |
|
Shutting Off Burners Only (pilot stays lit) | |
Turn control knob clockwise | to the |
PILOT position. |
|
THERMOSTAT |
|
CONTROL OPERATION |
|
You can set the thermostat control knob to any | |
comfort level between HI and LO. The thermo- | |
stat will gradually modulate the heat output | |
and flame height from higher to lower settings, | |
or pilot, in order to maintain the comfort level | |
you select. The ideal comfort setting will vary | |
by household depending upon the amount of | |
space to be heated, the output of the central | |
heating system, etc. |
|
Note: Selecting the HI setting will cause the burner to remain on without modulating down in most cases.
MANUAL LIGHTING
PROCEDURE
1.Follow steps 1 through 5 under Lighting Instructions, page 17.
2.Depress control knob and light pilot with match.
3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8 under Lighting Instructions, column 1.
BLOWER
OPERATION
WARNING: This fireplace has
Locate the blower switch by opening lower louver on fireplace. Blower switch is located at lower left inside louver door. This
18 | www.desatech.com |