SAFETY INFORMATION

Continued

3.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighborʼs phone. Follow the gas supplierʼs instructions

if you cannot reach your gas supplier, call the fire department

4.This fireplace shall not be installed in a bed- room or bathroom.

5.Do not use this fireplace as a wood-burning fireplace. Use only the logs provided with the fireplace.

6.Do not add extra logs or ornaments such as pine cones, vermiculite, or rock wool. Using these added items can cause sooting. Do not add lava rock around base. Rock and debris could fall into the control area of fireplace.

7.This fireplace is designed to be smokeless. If logs ever appear to smoke, turn off fireplace and call a qualified service person. Note: During initial operation, slight smoking could occur due to log curing and fireplace burning manufacturing residues.

8.To prevent the creation of soot, follow the instructions in Cleaning and Maintenance, page 20.

9.Before using furniture polish, wax, carpet cleaner, or similar products, turn heater off. If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture.

10.This fireplace needs fresh air ventilation to run properly. This fireplace has an Oxygen Deple- tion Sensing (ODS) safety shutoff system. The ODS shuts down the fireplace if not enough fresh air is available. See Air for Combustion and Ventilation, page 6. If fireplace keeps shutting off, see Troubleshooting, page 21.

11.Do not run fireplace

where flammable liquids or vapors are used or stored

under dusty conditions

12.Do not use this fireplace to cook food or burn paper or other objects.

13.Do not use fireplace if any part has been exposed to or under water. Immediately call a qualified service technician to inspect the fireplace and to replace any part of the control system and any gas control which has been under water.

14.Do not operate fireplace if any log is broken. Do not operate fireplace if a log is chipped (dime-sized or larger).

15.Turn fireplace off and let cool before servicing. Only a qualified service person should service and repair fireplace.

16.Operating fireplace above elevations of 4,500 feet could cause pilot outage.

17.To prevent performance problems, do not use propane/LP fuel tanks of less than 100 lbs. capacity (propane/LP units only).

18.Provide adequate clearances around air openings.

LOCAL CODES

Install and use fireplace with care. Follow all local codes. In the absence of local codes, use the lat- est edition of The National Fuel Gas Code ANSI Z223.1/NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

4

www.desatech.com

113135-01C

Image 4
Contents What to do if YOU Smell GAS Table of Contents Safety Information Local Codes Product Identification Product FeaturesUnpacking AIR for Combustion Ventilation Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Unusually Tight ConstructionVentilation AIR Ventilation Air From Inside BuildingInstallation Ventilation Air From OutdoorsCheck GAS Type Installing HoodElectrical Hookup Installation Clearances Conventional Fireplace InstallationBUILT-IN Fireplace Installation Height Actual Framing Front Width DepthInstalling GAS Piping to Fireplace LocationInstallation Items Needed External Regulator with Vent Pointing DownConnecting Fireplace to GAS Supply Natural GasChecking GAS Connections Test Pressures In Excess Of 1/2 Psig 3.5 kPaThan Psig 3.5 kPaInstalling Logs Installing Front Log #1For Your Safety Read Before Lighting Operating FireplaceLighting Instructions Ignitor Button ControlManual Lighting Procedure To Turn OFF GAS To ApplianceThermostat Control Operation Blower OperationPilot Flame Pattern Inspecting BurnersFront Burner Flame Pattern Burner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceLogs Troubleshooting Observed Problem Possible Cause RemedyMaintenance, Stalling Logs, Gas leak. See Warning Statement aboveSpecifications Wiring DiagramService Hints Replacement PartsLOG Base Assembly Models VSGF28NTE and VSGF28PTE Illustrated Parts BreakdownParts List LOG Base AssemblyFireplace Models VSGF28NTE and VSGF28PTE KEY Part Number Description QTY Accessories Perimeter Trim Accessory Hardwood Hearth BaseDuplex Outlet KIT GA3555 Extruded Louver KITKeep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS Fireplace