SPECIFICATIONS

 

VSGF28NTE

VSGF28PTE

Btu (Low/High)

20,000/28,000

23,000/28,000

Type Gas

Natural Gas Only

Propane/LP Gas Only

Ignition

Piezo

Piezo

Manifold Pressure

3.4" W.C.

7.9" W.C.

Inlet Gas Pressure (in. of water)

 

Maximum

10.5"

14"

Minimum

5"

11"

Shipping Weight

100 lbs.

100 lbs.

WIRING DIAGRAM

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dan- gerous operation. Verify proper operation after servicing.

Variable

Fan SwitchFan Switch

(N.O.)

Off 1

2 Black

On Blue

Red

110/115

V.A.C.

Black

GreenBlower

WhiteMotor

Figure 36 - Blower Wiring Diagram for

Thermostat-Controlled Models

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

fireplace will not produce specified heat

propane/LP gas supply might be low

You may feel your gas pressure is too low. If so, contact your local propane/LP gas supplier.

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they canʼt supply original replacement part(s), call DESA Heating Productsʼ Technical Service Department at 1-866-672-6040.

When calling DESA Heating Products, have ready

your name

your address

model and serial numbers of your fireplace

how fireplace was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the part to the factory.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product. If they canʼt supply original replacement part(s), call DESA Heating Products at 1-866-672-6040 for referral information.

When calling DESA Heating Products, have ready

model number of your fireplace

the replacement part number

TECHNICAL SERVICE

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA Heating ProductsʼTechnical Service Department at 1-866-672-6040. When calling, please have your model and serial numbers of your heater ready.

You can also visit DESA Heating Productsʼtechni- cal services web site at www.desatech.com.

113135-01C

www.desatech.com

25

Image 25
Contents What to do if YOU Smell GAS Table of Contents Safety Information Local Codes Product Identification Product FeaturesUnpacking Providing Adequate Ventilation AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Unusually Tight ConstructionVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors InstallationCheck GAS Type Installing HoodElectrical Hookup Conventional Fireplace Installation Installation ClearancesHeight Actual Framing Front Width Depth BUILT-IN Fireplace InstallationFireplace Location Installing GAS Piping toExternal Regulator with Vent Pointing Down Installation Items NeededNatural Gas Connecting Fireplace to GAS SupplyTest Pressures In Excess Of 1/2 Psig 3.5 kPa Checking GAS ConnectionsThan Psig 3.5 kPaInstalling Front Log #1 Installing LogsOperating Fireplace For Your Safety Read Before LightingLighting Instructions Ignitor Button ControlTo Turn OFF GAS To Appliance Manual Lighting ProcedureThermostat Control Operation Blower OperationPilot Flame Pattern Inspecting BurnersFront Burner Flame Pattern Burner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceLogs Observed Problem Possible Cause Remedy TroubleshootingMaintenance, Stalling Logs, Statement above Gas leak. See WarningWiring Diagram SpecificationsService Hints Replacement PartsIllustrated Parts Breakdown LOG Base Assembly Models VSGF28NTE and VSGF28PTELOG Base Assembly Parts ListFireplace Models VSGF28NTE and VSGF28PTE KEY Part Number Description QTY Accessories Hardwood Hearth Base Perimeter Trim AccessoryDuplex Outlet KIT GA3555 Extruded Louver KITKeep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS Fireplace