Set Screws

INSTALLATION

Continued

IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, installing fire- place in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, page 6.

IMPORTANT: Make sure the fireplace is level. If fireplace is not level, log set will not work properly.

CHECK GAS TYPE

Use the correct gas type (natural or propane/LP). If your gas supply is not correct, do not install fireplace. Call dealer where you bought fireplace for proper type fireplace.

WARNING: This appliance is equipped for (natural or pro- pane/LP) gas. Field conversion is not permitted.

ELECTRICAL HOOKUP

This fireplace has a blower assembly with an electrical cord. The electrical cord is five feet in length. You must locate fireplace within reach of a 120-volt grounded electrical outlet. If not, you must install an electrical outlet within reach of fireplace power cord. The GA3555 outlet acces- sory may be used for built-in installation when a blower is installed.

INSTALLING HOOD

Install hood to rail already installed in fireplace as shown in Figure 5. Use 3 Phillips screws provided.

Rail

Hood

Screw

ASSEMBLING AND ATTACHING OPTIONAL PERIMETER TRIM (Included with Mantel Accessory)

IMPORTANT: If you are recessing the firebox in a wall, do not attach trim at this time. See page 10 for built-in fireplace installation.

Note: The instructions below show assembling and attaching trim to fireplace.

1.Remove packaging from three pieces of trim.

2.Locate four screws, two adjusting plates with set screws, and two shims in the hardware packet.

3.Align shim under adjusting plate as shown in Figure 6.

4.Slide one end of adjusting plate/shim in slot on mitered edge of top trim (see Figure 6).

5.Slide other end of adjusting plate/shim in slot on mitered edge of side trim (see Figure 6).

6.While firmly holding edges of trim together, tighten both set screws on the adjusting plate with slotted screwdriver.

7.Repeat steps 1 through 6 for other side.

8.Tighten trim hanging screws (#10 x 6.25 shoulder) into holes in cabinets. Place the assembled trim onto fireplace cabinet. Align hanging notches on trim with hanging screws on side of fireplace (see Figure 7). Push trim firmly into place, sliding hanging notches over

hanging screws.

Side Trim

Adjusting

Top

Plate

 

Trim

 

 

Slot

 

 

 

Shim

 

 

Mitered Edge

Slot

Figure 6 - Assembling Perimeter Trim

 

Trim Hanging

 

Screws

Figure 5 - Installing Hood

Assembled

 

Trim

Hanging Notches

 

 

on Trim

Figure 7 - Attaching Perimeter Trim to

 

Fireplace

113135-01C

www.desatech.com

9

Image 9
Contents What to do if YOU Smell GAS Table of Contents Safety Information Local Codes Product Features Product IdentificationUnpacking Providing Adequate Ventilation AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Unusually Tight ConstructionVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors InstallationInstalling Hood Check GAS TypeElectrical Hookup Conventional Fireplace Installation Installation ClearancesHeight Actual Framing Front Width Depth BUILT-IN Fireplace InstallationFireplace Location Installing GAS Piping toExternal Regulator with Vent Pointing Down Installation Items NeededNatural Gas Connecting Fireplace to GAS SupplyTest Pressures In Excess Of 1/2 Psig 3.5 kPa Checking GAS ConnectionsThan Psig 3.5 kPaInstalling Front Log #1 Installing LogsOperating Fireplace For Your Safety Read Before LightingLighting Instructions Ignitor Button ControlTo Turn OFF GAS To Appliance Manual Lighting ProcedureThermostat Control Operation Blower OperationInspecting Burners Pilot Flame PatternFront Burner Flame Pattern Cleaning Maintenance Burner Injector Holder and Pilot AIR Inlet HoleLogs Observed Problem Possible Cause Remedy TroubleshootingMaintenance, Stalling Logs, Statement above Gas leak. See WarningWiring Diagram SpecificationsService Hints Replacement PartsIllustrated Parts Breakdown LOG Base Assembly Models VSGF28NTE and VSGF28PTELOG Base Assembly Parts ListFireplace Models VSGF28NTE and VSGF28PTE KEY Part Number Description QTY Accessories Hardwood Hearth Base Perimeter Trim AccessoryDuplex Outlet KIT GA3555 Extruded Louver KITWarranty Information Keep this WarrantyLimited Warranty VENT-FREE GAS Fireplace