Vanguard Heating VMH10TN Connecting Fireplace to GAS Supply, Installation Items Needed

Page 17

CONNECTING

CONNECTING FIREPLACE TO GAS SUPPLY

 

Installation Items Needed

 

• Phillips screwdriver

 

TO GAS

 

• sealant (resistant to propane gas, not provided)

 

SUPPLY

1. Remove fireplace screen. Remove two screws that hold fireplace screen in place

 

Continued

for shipping. These screws are located near top of screen. Discard screws. Lift

fireplace screen up and pull out to remove.

 

 

2. Remove screws that attach branch support to fireplace (see Figure 17). Care-

 

fully lift up branch support and remove from fireplace (see Figure 17).

 

Branch

Screen Shipping

 

Support

Screw

 

 

Shoulder Screw

 

Screen

Flexible Gas Line

 

 

Figure 17 - Removing Log Base Assembly From Fireplace

3.Route flexible gas line from manual shutoff valve into fireplace through side or rear access holes in outer casing. Route flexible gas supply line through fireplace access holes in outer casing.

NOTICE

Most building codes do not permit concealed gas connections. A flexible gas line is provided to allow accessibility from the fireplace. The flexible gas supply line connection to the manual shutoff valve should be accessible.

4.Apply pipe joint sealant lightly to male threads of gas connector attached to flexible gas line (see Figure 18). Connect flexible gas line to flexible gas line attached to gas regulator of fireplace (see Figure 18).

5.Check all gas connections for leaks. See Checking Gas Connections, below.

6.Replace branch support back into fireplace. Feed flexible gas line into fireplace base area while replacing branch support. Make sure the entire flexible gas line is in fireplace base area. Reattach branch support to fireplace with screws removed in step 3.

To Fireplace

 

 

 

Gas Regulator

Gas Connector

Manual Shutoff Valve

 

 

Flexible Gas Line

 

 

To Gas

 

 

Supply

from Fireplace Gas

 

 

Flexible Gas Line from

Regulator

 

 

Manual Shutoff Valve

Figure 18 - Attaching Flexible Gas Lines Together

Continued

103670

17

Image 17
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information ContentsSafety Product Identification FeaturesLocal Codes ProductAssembling Fireplace AssemblyInstalling Log Providing Adequate Ventilation AIR for CombustionVentilation Determining if You Have a Confined or Unconfined Space AIR forDetermining FRESH-AIR Flow for Fireplace Location Tion and ventilation air by one of the methods described Ventilation AIRCable local codes Ventilation Air From Inside BuildingVentilation Air From Outdoors AIR for Combustion and VentilationInstallation Items InstallationCheck GAS Type Locating FireplaceInstallation BUILT-IN Fireplace Installation InstallingGas Supply, Mantel Clearances for Built-In InstallationAttaching Brass Trim to Fireplace Optional Mantel InstallationAttaching Wood Base to Solid Floor Assembling Brass Trim Brass trim shipped with mantelTo GAS ConnectingSupply Follow all local codesInstallation Items Needed Connecting Fireplace to GAS SupplyPressure Testing Fireplace GAS Connections Pressure Testing GAS Supply Piping SystemChecking GAS ConnectionsFireplace Pilot Operating FireplaceShutting Off Burner Only pilot stays lit Shutting Off FireplacePilot Flame Pattern Inspecting BurnerCorrect Burner Flame Pattern Burner Flame PatternObserved Possible Problem Cause Remedy Cleaning and Maintenance Trouble ShootingODS/PILOT and Burner CabinetSee Cleaning TROUBLE- Shooting Top Ing statement atReplacement ServiceTechnical HintsAccessories VMH10TN Model VMH10TN Parts ListVENT-FREE Natural GAS Compact Classic HEARTHâ Fireplace Warranty InformationLimited Warranty