Vanguard Heating VMH10TN installation manual Safety

Page 3

SAFETY

WARNING ICONG 001WARNINGS Continued

INFORMATION

WARNING: Any change to this fireplace or its controls can be dangerous.

Continued

1. This appliance is only for use with the type of gas indicated on the rating plate. This

appliance is not convertible for use with other gases.

 

2.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building.

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

3.This fireplace shall not be installed in a bathroom.

4.Never install the fireplace

in a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the fireplace

as a fireplace insert

in high traffic areas

in windy or drafty areas

5.Do not use this fireplace as a wood-burning fireplace. Use only the logs provided with the fireplace.

6.Do not add extra logs or ornaments such as pine cones, vermiculite, or rock wool. Using these added items can cause sooting. Do not add lava rock around base. Rock and debris could fall into the control area of fireplace.

7.You must operate this fireplace with the fireplace screen in place. Make sure fireplace screen is in place before running fireplace.

8.This fireplace is designed to be smokeless. If logs ever appear to smoke, turn off fireplace and call a qualified service person. Note: During initial operation, slight smoking could occur due to log curing and fireplace burning manufacturing residues.

9.Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can cause sooting.

10.This fireplace needs fresh air ventilation to run properly. This fireplace has an oxygen depletion sensor (ODS) pilot light safety system. The ODS shuts down the fireplace if not enough fresh air is available. See Air for Combustion and Ventilation, pages 6 through 9. If fireplace keeps shutting off, see Troubleshooting, pages 24 through 27.

11.Do not run fireplace

where flammable liquids or vapors are used or stored.

under dusty conditions.

12.Do not use this fireplace to cook food or burn paper or other objects.

13.Never place any objects in the fireplace or on logs.

14.Fireplace front and screen becomes very hot when running fireplace. Keep children and adults away from hot surfaces to avoid burns or clothing ignition. Fireplace will remain hot for a time after shut-down. Allow surfaces to cool before touching.

15.Carefully supervise young children when they are in same room with fireplace.

16.Do not use fireplace if any part has been under water. Immediately call a qualified service technician to inspect the room fireplace and to replace any part of the control system and any gas control which has been under water.

17.Turn off and unplug fireplace and let cool before servicing. Only a qualified service person should service and repair fireplace.

18.Operating fireplace above elevations of 4,500 feet could cause pilot outage.

19.Do not use a blower insert, heat exchanger insert, or other accessory not approved for use with this fireplace.

20.Do not operate fireplace if any log is broken. Do not operate fireplace if a log is chipped (dime-sized or larger).

3

103670

Image 3
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information ContentsSafety Product FeaturesProduct Identification Local CodesAssembly Installing LogAssembling Fireplace AIR for Combustion VentilationProviding Adequate Ventilation AIR for Determining FRESH-AIR Flow for Fireplace LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRTion and ventilation air by one of the methods described Cable local codesVentilation Air From Outdoors AIR for Combustion and VentilationLocating Fireplace InstallationInstallation Items Check GAS TypeInstallation BUILT-IN Fireplace Installation InstallingGas Supply, Mantel Clearances for Built-In InstallationAttaching Brass Trim to Fireplace Optional Mantel InstallationAttaching Wood Base to Solid Floor Assembling Brass Trim Brass trim shipped with mantelFollow all local codes ConnectingTo GAS SupplyInstallation Items Needed Connecting Fireplace to GAS SupplyConnections Pressure Testing GAS Supply Piping SystemPressure Testing Fireplace GAS Connections Checking GASFireplace Pilot Operating FireplaceShutting Off Burner Only pilot stays lit Shutting Off FireplacePilot Flame Pattern Inspecting BurnerCorrect Burner Flame Pattern Burner Flame PatternCabinet Cleaning and Maintenance Trouble ShootingObserved Possible Problem Cause Remedy ODS/PILOT and BurnerSee Cleaning TROUBLE- Shooting Top Ing statement atHints ServiceReplacement TechnicalAccessories VMH10TN Model VMH10TN Parts ListWarranty Information Limited WarrantyVENT-FREE Natural GAS Compact Classic HEARTHâ Fireplace