CONNECTING TO GAS SUPPLY
Continued
CHECKING GAS CONNECTIONS
18
4.Apply pipe joint sealant lightly to male threads of gas connector attached to flexible gas line (see Figure 18). Connect flexible gas line to flexible gas line attached to gas regulator of fireplace (see Figure 18).
5.Check all gas connections for leaks. See Checking Gas Connections, below.
6.Replace branch support back into fireplace. Feed flexible gas line into fireplace base area while replacing branch support. Make sure the entire flexible gas line is in fireplace base area. Reattach branch support to fireplace with screws removed in step 3.
To Fireplace |
|
|
|
| |
Gas Regulator➞ | Gas Connector | Manual Shutoff Valve | |||
|
| ||||
Flexible Gas Line |
|
|
| To Gas | |
from Fireplace Gas |
|
|
| ||
Flexible Gas Line from | ➞ | Supply | |||
Regulator | |||||
|
|
|
Manual Shutoff Valve
Figure 19 - Attaching Flexible Gas Lines Together
WARNING
WARNING ICONG 001
Test all gas piping and connections for leaks after installing or servicing. Correct all leaks at once.
WARNING
WARNING ICON | G 001 |
Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.
CAUTION
WARNING ICON | G 001 |
Make sure external regulator has been installed between propane/ LP supply and fireplace. See guidelines under Connecting to Gas Supply, page 16.
PRESSURE TESTING GAS SUPPLY PIPING SYSTEM
Test Pressures In Excess Of 1/2 PSIG
1.Disconnect fireplace and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage fireplace regulator.
2.Cap off open end of gas pipe where manual shutoff valve was connected.
3.Pressurize supply piping system by either using compressed air or opening propane/LP supply tank valve.
4.Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.
5.Correct all leaks at once.
102886