INSTALLING
Continued
6.Attach flexible gas line to fireplace gas regulator. See Connecting Fireplace to Gas Supply, page 17.
7.If the optional blower has been installed connect blower to electrical source.
Option one: Route blower electrical cord through side or rear access door of fireplace. Plug electrical cord into electrical outlet.
Option two: Have a licensed electrician connect blower to electrical source at junction box inside fireplace.
8.Bend four nailing flanges on outer casing with pliers (see Figure 10).
9.Attach fireplace to wall studs using nails or wood screws through holes in nailing flange.
Nails or Wood
Screws
Nailing
Flanges
Figure 10 - Attaching Fireplace to Wall Studs
10.Check all gas connections for leaks. See Checking Gas Connections, page 18.
11.If using optional brass trim kit, install the trim after final finishing and/or painting of wall. See instructions included with brass trim accessory for attach- ing brass trim.
Mantel Clearances for Built-In Installation
If placing mantel above
10"
8"
6"
2 1/2"
Side of
Firebox
Mantel Shelf
20" |
| 241/2" | 271/2" |
|
Distances to
Underside of
Underside of
Mantel Shelf
All minimum distances are in inches
30"
Top of Fireplace Opening
Figure 11 - Minimum Mantel Clearances for Built-In Installation
If your installation does not meet the above minimum clearances, you must:
• | raise the mantel to an acceptable height, OR |
|
| |
• | remove the mantel. | Continued |
| |
13 | ||||
|
| |||
|
|
|
|