TROUBLE- SHOOTING

Continued

WARNING

WARNING ICON

G 001

If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating fireplace where impurities in air exist may create odors. Clean- ing supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.

 

OBSERVED

POSSIBLE

 

 

 

PROBLEM

CAUSE

REMEDY

 

 

 

 

 

 

 

Fireplace produces a

1.

Metal expanding while

1.

This is common with

 

clicking/ticking noise

 

heating or contracting

 

most fireplaces. If noise

 

just after burner is lit

 

while cooling

 

is excessive, contact

 

or shut off

 

 

 

qualified service person

 

 

 

 

 

 

 

Fireplace produces

1.

Fireplace burning vapors

1.

Ventilate room. Stop

 

unwanted odors

 

from paint, hair spray,

 

using odor causing

 

 

 

glues, etc. (See IMPOR-

 

products while fire-

 

 

 

TANT statement above)

 

place is running

 

 

2.

Low fuel supply

2.

Refill supply tank

 

 

3.

Gas leak. See Warn-

3.

Locate and correct all

 

 

 

ing statement at top

 

leaks (see Checking Gas

 

 

 

of page

 

Connections, page 18)

 

 

 

 

 

 

 

Fireplace shuts off in

1.

Not enough fresh air is

1.

Open window and/or

 

use (ODS operates)

 

available

 

door for ventilation

 

 

2.

Low line pressure

2.

Contact local propane/

 

 

 

 

 

LP gas company

 

 

3.

ODS/pilot is partially

3.

Clean ODS/pilot (see

 

 

 

clogged

 

Cleaning and Mainte-

 

 

 

 

 

nance, page 25)

 

 

 

 

 

 

 

Gas odor even when

1.

Gas leak. See Warn-

1.

Locate and correct all

 

control knob is in

 

ing statement at top

 

leaks (see Checking Gas

 

OFF position

 

of page

 

Connections, page 18)

 

 

2.

Control valve defective

2.

Replace control valve

 

 

 

 

 

 

 

Gas odor during

1.

Foreign matter between

1.

Take apart gas tubing

 

combustion

 

control valve and

 

and remove foreign

 

 

 

burner

 

matter

 

 

2.

Gas leak. See Warn-

2.

Locate and correct all

 

 

 

ing statement at top

 

leaks (see Checking Gas

 

 

 

of page

 

Connections, page 18)

 

 

 

 

 

 

Moisture/condensa-

1.

Not enough combus-

1. Refer to Air for Combus-

 

tion noticed on

 

tion/ventilation air.

 

tion and Ventilation re-

 

windows

 

 

 

quirements

 

 

 

 

 

(page 6)

102886

Image 28
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety Information Safety Information Local Codes Product Features Unpacking Safety PilotPiezo Ignition System Thermostatic Heat ControlAssembly Installing LogAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Fireplace Location Determining if You Have a Confined or Unconfined SpaceVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Ventilation Air from Outdoors Shown with Optional MantelInstallation Installation ItemsCheck GAS Type Locating FireplaceCeiling Installing BUILT-IN Fireplace InstallationMantel Clearances for Built-In Installation Side Firebox Mantel ShelfOptional Mantel Installation Attaching Brass Trim to FireplaceAssembling Brass Trim Brass trim shipped with mantel Attaching Wood Base to Solid FloorConnecting to GAS Supply External Regulator with Vent Pointing DownConnecting Fireplace to GAS Supply Installation Items NeededConnecting to GAS Supply Checking GAS Connections Pressure Testing GAS Supply Piping SystemPressure Testing Fireplace GAS Connections Manual Shutoff ValveOperating Fireplace Pilot Shutting Off Fireplace Shutting Off Burner Only pilot stays litInspecting Burner Pilot Flame PatternBurner Flame Pattern Correct Burner Flame PatternODS/PILOT and Burner Cleaning and Maintenance Trouble ShootingCabinet See Cleaning TROUBLE- ShootingObserved Possible Remedy Problem Cause Ing statement at top Connections,Technical Service Service HintsParts Under Warranty Parts Not Under WarrantyVMH26TP Parts List Model VMH26TPAccessories Valve GA5010GA3400T Unfinished GM921U Finished GM920F102886 102886 102886 Warranty Information Keep this Warranty