28
TROUBLE- SHOOTING
Continued
WARNING
WARNING ICON | G 001 |
If you smell gas
•Shut off gas supply.
•Do not try to light any appliance.
•Do not touch any electrical switch; do not use any phone in your building.
•Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
•If you cannot reach your gas supplier, call the fire department.
IMPORTANT: Operating fireplace where impurities in air exist may create odors. Clean- ing supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.
| OBSERVED | POSSIBLE |
|
| |
| PROBLEM | CAUSE | REMEDY | ||
|
|
|
|
|
|
| Fireplace produces a | 1. | Metal expanding while | 1. | This is common with |
| clicking/ticking noise |
| heating or contracting |
| most fireplaces. If noise |
| just after burner is lit |
| while cooling |
| is excessive, contact |
| or shut off |
|
|
| qualified service person |
|
|
|
|
|
|
| Fireplace produces | 1. | Fireplace burning vapors | 1. | Ventilate room. Stop |
| unwanted odors |
| from paint, hair spray, |
| using odor causing |
|
|
| glues, etc. (See IMPOR- |
| products while fire- |
|
|
| TANT statement above) |
| place is running |
|
| 2. | Low fuel supply | 2. | Refill supply tank |
|
| 3. | Gas leak. See Warn- | 3. | Locate and correct all |
|
|
| ing statement at top |
| leaks (see Checking Gas |
|
|
| of page |
| Connections, page 18) |
|
|
|
|
|
|
| Fireplace shuts off in | 1. | Not enough fresh air is | 1. | Open window and/or |
| use (ODS operates) |
| available |
| door for ventilation |
|
| 2. | Low line pressure | 2. | Contact local propane/ |
|
|
|
|
| LP gas company |
|
| 3. | ODS/pilot is partially | 3. | Clean ODS/pilot (see |
|
|
| clogged |
| Cleaning and Mainte- |
|
|
|
|
| nance, page 25) |
|
|
|
|
|
|
| Gas odor even when | 1. | Gas leak. See Warn- | 1. | Locate and correct all |
| control knob is in |
| ing statement at top |
| leaks (see Checking Gas |
| OFF position |
| of page |
| Connections, page 18) |
|
| 2. | Control valve defective | 2. | Replace control valve |
|
|
|
|
|
|
| Gas odor during | 1. | Foreign matter between | 1. | Take apart gas tubing |
| combustion |
| control valve and |
| and remove foreign |
|
|
| burner |
| matter |
|
| 2. | Gas leak. See Warn- | 2. | Locate and correct all |
|
|
| ing statement at top |
| leaks (see Checking Gas |
|
|
| of page |
| Connections, page 18) |
|
|
|
|
| |
| Moisture/condensa- | 1. | Not enough combus- | 1. Refer to Air for Combus- | |
| tion noticed on |
| tion/ventilation air. |
| tion and Ventilation re- |
| windows |
|
|
| quirements |
|
|
|
|
| (page 6) |
102886