Btu (Variable) | 14,000/26,000 |
Type Gas | Propane/LP Only |
Ignition | Piezo |
Pressure Regulator Setting | 8" W.C. |
Inlet Gas Pressure (in. of water) * |
|
Maximum | 14" |
Minimum | 11" |
Dimensions, Inches (H x W x D) | 257/8 x 2613/16 x 93/8 |
Fireplace (including hood and screws) | |
Carton | 325/8 x 273/16 x 115/8 |
Weight, pounds | 441/2 lbs. |
Fireplace | |
Shipping | 48 lbs. |
* For purposes of input adjustment |
|
When gas pressure is too low
•pilot will not stay lit
•burner will have delayed ignition
•fireplace will not produce specified heat
•propane/LP gas supply may be low
When gas quality is bad
•pilot will not stay lit
•burner will produce flames and soot
•fireplace will backfire when lit
You may feel your gas pressure is too low or gas quality is bad. If so, contact your local propane/LP gas supplier.
Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.
Parts Under Warranty
Contact authorized dealers of this product. If they can’t supply original replacement part(s) call DESA International’s Technical Service Department at
When calling DESA International, have ready
•your name
•your address
•model number of your fireplace
•how fireplace was malfunctioning
•type of gas used (propane/LP or natural gas)
•purchase date
Usually, we will ask you to return the defective part to the factory.
Parts Not Under Warranty
Contact authorized dealers of this product. If they can’t supply original replacement part(s) call DESA International’s Parts Department at
When calling DESA International, have ready
•model number of your fireplace
•the replacement part number