Vanguard Heating VP2800BTC, VP2000BTC Marking Screw Locations, Attaching Mounting Bracket To Wall

Page 12

INSTALLING TO

Marking Screw Locations

WALL

1. Tape mounting bracket to wall where heater will be located. Make sure mount-

ing bracket is level.

Continued

 

WARNING ICONG 001 WARNING

 

 

Maintain minimum clearances shown in Figure 8. If you can,

 

provide greater clearances from floor and joining wall.

 

 

2.Mark screw locations on wall (see Figure 8).

Note: Only mark last hole on each end of mounting bracket. Insert mounting screws through these holes only.

3.Remove tape and mounting bracket from wall.

11"

16"

7 1/4"

16"

Min.

 

Min.

 

AdjoiningWall

 

AdjoiningWall

Only Insert Mounting

 

Only Insert Mounting

18 3/4"

 

18 3/4"

Screws Through Last

Min.

 

Screws Through Last

Min.

Hole On Each End

 

Hole On Each End

 

 

 

Floor

 

 

 

Floor

 

 

 

 

 

 

 

 

Models VP2800BTC

 

 

Models VP2000BTC

 

Figure 8 - Mounting Bracket Clearances

Attaching Mounting Bracket To Wall

Note: Wall anchors, mounting screws, and spacers are in hardware package. The hardware package is provided with heater.

Attaching to wall stud method

For attaching mounting bracket to wall studs

1.Drill holes at marked locations using 9/64" drill bit.

2.Place mounting bracket onto wall. Line up last hole on each end of bracket with holes drilled in wall.

3.Insert mounting screws through bracket and into wall studs.

4.Tighten screws until mounting bracket is firmly fastened to wall studs.

Attaching to wall anchor method

For attaching mounting bracket to hollow walls (wall areas between studs) or solid walls (concrete or masonry)

1.Drill holes at marked locations using 5/16" drill bit. For solid walls (concrete or masonry), drill at least 1" deep.

2.Fold wall anchor as shown in Figure 9.

 

Figure 9 - Folding Anchor

 

3. Insert wall anchor (wings first) into hole. Tap anchor flush to wall.

12

Continued

 

 

103876

Image 12
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety InformationSafety Features Product IdentificationLocal Codes UnpackingAIR for Combustion VentilationProviding Adequate Ventilation AIR for Combustion and Ventilation Determining AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Ventilation Air from Outdoors Installing To Wall Installation Items Check GAS Type Locating HeaterThermostat Sensing Bulb Locating Thermostat Sensing BulbAttaching Thermostat Sensing Bulb Installing Heater to Wall WallMounting Bracket Removing Front Panel Of HeaterMarking Screw Locations Maintain minimum clearances shown in . If you canProvide greater clearances from floor and joining wall Attaching Mounting Bracket To WallInstalling Bottom Mounting Screws Placing Heater On Mounting BracketConnecting To GAS SupplyPressure Testing GAS Supply Piping System Checking GASConnections Pressure Testing Heater GAS Connections CheckingFor Your Safety Read Before Lighting Operating HeaterOperating Heater Manual Lighting Procedure Shutting Off HeaterShutting Off Burner Only pilot stays lit Inspecting Burner Pilot Flame PatternBurner Flame Pattern Correct Burner Flame PatternCleaning and Maintenance Trouble Shooting Observed Possible Problem Cause RemedyODS/PILOT and Burner CabinetProblem Cause Observed Possible RemedyCleaning and Mainte TROUBLE- ShootingTrouble Shooting Technical Service Service HintsVP2000BTC VP2800BTC Service Publications Replacement Parts Parts Under WarrantyParts Not Under Warranty VP2000BTC VP2800BTC Parts List KEY Part Number for VP2000BTC VP2800BTC Description QTYAccessories Floor Mounting StandModel VP2000BTC GA4000B Model VP2800BTC GA4010B Manual Shutoff103876 Warranty Information Limited Warranty VENT-FREE Residential GAS Heaters