Vanguard Heating VP2800BTC, VP2000BTC installation manual Connecting To GAS, Supply

Page 14

CONNECTING

NOTICE

TO GAS

A qualified service person must connect heater to gas supply.

SUPPLY

Follow all local codes.

 

 

 

WARNING ICONG 001 CAUTION

 

Never connect heater directly to the propane supply. This heater

 

requires an external regulator (not supplied). Install the external

 

regulator between the heater and propane supply.

 

 

The installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install the external regulator with the vent pointing down as shown in Figure 13. Pointing the vent down protects it from freezing rain or sleet.

Propane

Supply Tank

External

Regulator

 

 

Vent Pointing

 

 

Down

 

Figure 13 - External Regulator With Vent Pointing Down

 

WARNING ICONG 001 CAUTION

 

Use only new, black iron or steel pipe. Internally-tinned copper

 

tubing may be used in certain areas. Check your local codes. Use

 

pipe of large enough diameter to allow proper gas volume to heater.

 

If pipe is too small, undue loss of pressure will occur.

 

Typical Inlet Pipe Diameters

 

VP2000BTC

3/8" or greater

 

VP2800BTC

1/2" or greater

 

Installation must include a manual shutoff valve, union, and plugged 1/8" NPT tap.

 

Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream

 

from heater (see Figure 14, page 15).

 

 

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant

 

from going into pipe. Excess sealant in pipe could result in clogged heater valves.

 

WARNING ICONG 001 CAUTION

 

Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.

 

Install sediment trap in supply line as shown in Figure 14, page 15. Locate sediment

 

trap where it is within reach for cleaning. Locate sediment trap where trapped

 

matter is not likely to freeze. A sediment trap traps moisture and contaminants. This

 

keeps them from going into heater controls. If sediment trap is not installed or is

14

installed wrong, heater may not run properly.

103876

Image 14
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety InformationSafety Local Codes FeaturesProduct Identification UnpackingProviding Adequate Ventilation AIR for CombustionVentilation Determining if You Have a Confined or Unconfined Space AIR for Combustion and VentilationDetermining AIR Flow for Heater Location Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Ventilation Air from OutdoorsCheck GAS Type Installing To WallInstallation Items Locating HeaterAttaching Thermostat Sensing Bulb Thermostat Sensing BulbLocating Thermostat Sensing Bulb Mounting Bracket Installing Heater to Wall Wall Removing Front Panel Of HeaterProvide greater clearances from floor and joining wall Marking Screw LocationsMaintain minimum clearances shown in . If you can Attaching Mounting Bracket To WallInstalling Bottom Mounting Screws Placing Heater On Mounting BracketConnecting To GAS SupplyConnections Pressure Testing GAS Supply Piping SystemChecking GAS Pressure Testing Heater GAS Connections CheckingFor Your Safety Read Before Lighting Operating HeaterOperating Heater Shutting Off Burner Only pilot stays lit Manual Lighting ProcedureShutting Off Heater Inspecting Burner Pilot Flame PatternBurner Flame Pattern Correct Burner Flame PatternODS/PILOT and Burner Cleaning and Maintenance Trouble ShootingObserved Possible Problem Cause Remedy CabinetProblem Cause Observed Possible RemedyCleaning and Mainte TROUBLE- ShootingTrouble Shooting VP2000BTC VP2800BTC Technical ServiceService Hints Parts Not Under Warranty Service Publications Replacement PartsParts Under Warranty VP2000BTC VP2800BTC Parts List KEY Part Number for VP2000BTC VP2800BTC Description QTYModel VP2000BTC GA4000B Model VP2800BTC GA4010B AccessoriesFloor Mounting Stand Manual Shutoff103876 Warranty Information Limited Warranty VENT-FREE Residential GAS Heaters