Vanguard Heating VP2000BTC, VP2800BTC Installing To Wall, Check GAS Type, Installation Items

Page 9

INSTALLING

NOTICE

 

 

TO WALL

 

 

A qualified service person must install heater. Follow all local codes.

 

 

 

 

 

 

CHECK GAS TYPE

 

 

 

 

Use only propane/LP gas. If your gas supply is not propane/LP, do not install

 

heater. Call dealer where you bought heater for proper type heater.

 

 

INSTALLATION ITEMS

 

 

 

 

Before installing heater, make sure you have the items listed below.

 

 

• external regulator (supplied by

• manual shutoff valve *

sediment trap

 

installer, see page 14)

• ground joint union

tee joint

 

• piping (check local codes)

• test gauge connection *

• pipe wrench

 

• sealant (resistant to propane/LP gas)

(see Figure 14, page 15)

 

 

*An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. The optional A.G.A. design-certified manual shutoff valve can be purchased from your dealer. See Accessories, page 30.

LOCATING HEATER

This heater is designed to be mounted on a wall.

WARNING

WARNING ICON

G 001

Maintain the minimum clearances shown in Figure 4 (page 10). If you can, provide greater clearances from floor, ceiling, and joining wall.

You can locate heater on floor, away from a wall. An optional floor mounting stand is needed. Purchase the floor mounting stand from your dealer. See Accesso- ries, page 30.

WARNING

WARNING ICON

G 001

Never install the heater

in a bedroom or bathroom

in a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater

as a fireplace insert

in high traffic areas

in windy or drafty areas

CAUTION

WARNING ICON

G 001

This heater creates warm air currents. These currents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities in the air (such as tobacco smoke) exist, may discolor walls.

IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, in- stalling heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, pages 5 through 8.

CAUTION

WARNING ICON

G 001

If you install the heater in a home garage

heater pilot and burner must be at least 18 inches above floor

locate heater where moving vehicle will not hit it

Continued 9

103876

Image 9
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information ContentsSafety Product Identification FeaturesLocal Codes UnpackingAIR for Combustion VentilationProviding Adequate Ventilation AIR for Combustion and Ventilation Determining AIR Flow for Heater Location Determining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air from Outdoors Ventilation Air From OutdoorsInstallation Items Installing To WallCheck GAS Type Locating HeaterThermostat Sensing Bulb Locating Thermostat Sensing BulbAttaching Thermostat Sensing Bulb Wall Installing Heater to WallMounting Bracket Removing Front Panel Of HeaterMaintain minimum clearances shown in . If you can Marking Screw LocationsProvide greater clearances from floor and joining wall Attaching Mounting Bracket To WallPlacing Heater On Mounting Bracket Installing Bottom Mounting ScrewsSupply Connecting To GASPressure Testing GAS Supply Piping System Checking GASConnections Checking Pressure Testing Heater GAS ConnectionsOperating Heater For Your Safety Read Before LightingOperating Heater Manual Lighting Procedure Shutting Off HeaterShutting Off Burner Only pilot stays lit Pilot Flame Pattern Inspecting BurnerCorrect Burner Flame Pattern Burner Flame PatternObserved Possible Problem Cause Remedy Cleaning and Maintenance Trouble ShootingODS/PILOT and Burner CabinetObserved Possible Remedy Problem CauseTROUBLE- Shooting Cleaning and MainteTrouble Shooting Technical Service Service HintsVP2000BTC VP2800BTC Service Publications Replacement Parts Parts Under WarrantyParts Not Under Warranty VP2000BTC VP2800BTC KEY Part Number for VP2000BTC VP2800BTC Description QTY Parts ListFloor Mounting Stand AccessoriesModel VP2000BTC GA4000B Model VP2800BTC GA4010B Manual Shutoff103876 Limited Warranty VENT-FREE Residential GAS Heaters Warranty Information