INSTALLING | NOTICE |
|
| |
TO WALL |
|
| ||
A qualified service person must install heater. Follow all local codes. | ||||
|
|
|
|
|
| CHECK GAS TYPE |
|
|
|
| Use only propane/LP gas. If your gas supply is not propane/LP, do not install | |||
| heater. Call dealer where you bought heater for proper type heater. |
| ||
| INSTALLATION ITEMS |
|
|
|
| Before installing heater, make sure you have the items listed below. |
| ||
| • external regulator (supplied by | • manual shutoff valve * | • | sediment trap |
| installer, see page 14) | • ground joint union | • | tee joint |
| • piping (check local codes) | • test gauge connection * | • pipe wrench | |
| • sealant (resistant to propane/LP gas) | (see Figure 14, page 15) |
|
|
*An A.G.A.
LOCATING HEATER
This heater is designed to be mounted on a wall.
WARNING
WARNING ICON | G 001 |
Maintain the minimum clearances shown in Figure 4 (page 10). If you can, provide greater clearances from floor, ceiling, and joining wall.
You can locate heater on floor, away from a wall. An optional floor mounting stand is needed. Purchase the floor mounting stand from your dealer. See Accesso- ries, page 30.
WARNING
WARNING ICON | G 001 |
Never install the heater
•in a bedroom or bathroom
•in a recreational vehicle
•where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater
•as a fireplace insert
•in high traffic areas
•in windy or drafty areas
CAUTION
WARNING ICON | G 001 |
This heater creates warm air currents. These currents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities in the air (such as tobacco smoke) exist, may discolor walls.
IMPORTANT:
CAUTION
WARNING ICON | G 001 |
If you install the heater in a home garage
•heater pilot and burner must be at least 18 inches above floor
•locate heater where moving vehicle will not hit it
Continued 9