Vanguard Heating VP2000BTC Checking GAS, Connections, Pressure Testing GAS Supply Piping System

Page 15

CONNECTING

IMPORTANT: Hold the pressure regulator with wrench when connecting it to gas

piping and/or fittings.

 

 

 

TO GAS

 

Note: Burner bracket

 

 

 

 

 

 

 

 

 

SUPPLY

 

 

Pressure

 

not shown for clarity

 

 

 

 

 

 

 

Regulator

 

 

 

Continued

 

 

 

 

 

 

 

 

3/8" NPT

 

 

 

 

 

Pipe Nipple

 

 

 

 

 

 

 

Ground Joint

Heater

 

 

 

 

Cabinet

 

 

 

 

Union

 

 

 

 

Tee Joint

 

 

 

 

 

 

Manual

 

 

 

 

 

 

Test

 

Reducer

 

Shutoff

 

Gauge

 

Bushing to

 

Valve *

 

Connection *

1/8" NPT

 

 

 

 

 

 

 

Typical Inlet

 

 

 

1/8" NPT

 

 

 

 

 

 

 

Pipe From

 

 

 

Plug Tap

 

 

 

 

 

 

External Regulator

 

 

 

 

 

 

 

 

Tee Joint

 

(11" W.C. to 14" W.C.

 

 

 

 

 

Pressure)

 

Sediment

Pipe

 

 

 

 

 

 

 

Trap

 

3" Minimum

 

 

 

Nipple

 

 

 

 

Cap

 

 

 

 

 

 

 

Figure 14 - Gas Connection

 

 

*An A.G.A. design certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional A.G.A. design certified manual shutoff valve from your dealer. See Accessories, page 30.

CHECKING

WARNING ICONG 001 WARNING

GAS

Test all gas piping and connections for leaks after installing or

CONNECTIONS

servicing. Correct all leaks at once.

 

 

 

 

WARNING ICONG 001 WARNING

 

Never use an open flame to check for a leak. Apply a mixture of

 

liquid soap and water to all joints. Bubbles forming show a leak.

 

Correct all leaks at once.

 

 

 

 

 

WARNING ICONG 001 CAUTION

 

Make sure external regulator has been installed between propane

 

supply and heater. See guidelines under Connecting to Gas Sup-

 

ply, page 14.

 

 

PRESSURE TESTING GAS SUPPLY PIPING SYSTEM

Test Pressures In Excess Of 1/2 PSIG

1.Disconnect heater and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 PSIG will damage heater regulator.

2.Cap off open end of gas pipe where manual shutoff valve was connected.

Continued 15

103876

Image 15
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information ContentsSafety Unpacking FeaturesProduct Identification Local CodesAIR for Combustion VentilationProviding Adequate Ventilation AIR for Combustion and Ventilation Determining AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air from Outdoors Ventilation Air From OutdoorsLocating Heater Installing To WallInstallation Items Check GAS TypeThermostat Sensing Bulb Locating Thermostat Sensing BulbAttaching Thermostat Sensing Bulb Removing Front Panel Of Heater Installing Heater to WallWall Mounting BracketAttaching Mounting Bracket To Wall Marking Screw LocationsMaintain minimum clearances shown in . If you can Provide greater clearances from floor and joining wallPlacing Heater On Mounting Bracket Installing Bottom Mounting ScrewsSupply Connecting To GASPressure Testing GAS Supply Piping System Checking GASConnections Checking Pressure Testing Heater GAS ConnectionsOperating Heater For Your Safety Read Before LightingOperating Heater Manual Lighting Procedure Shutting Off HeaterShutting Off Burner Only pilot stays lit Pilot Flame Pattern Inspecting BurnerCorrect Burner Flame Pattern Burner Flame PatternCabinet Cleaning and Maintenance Trouble ShootingObserved Possible Problem Cause Remedy ODS/PILOT and BurnerObserved Possible Remedy Problem CauseTROUBLE- Shooting Cleaning and MainteTrouble Shooting Technical Service Service HintsVP2000BTC VP2800BTC Service Publications Replacement Parts Parts Under WarrantyParts Not Under Warranty VP2000BTC VP2800BTC KEY Part Number for VP2000BTC VP2800BTC Description QTY Parts ListManual Shutoff AccessoriesFloor Mounting Stand Model VP2000BTC GA4000B Model VP2800BTC GA4010B103876 Limited Warranty VENT-FREE Residential GAS Heaters Warranty Information

VP2800BTC, VP2000BTC specifications

Vanguard Heating has made notable strides in the heating solutions market with its cutting-edge models, the VP2000BTC and VP2800BTC. These units cater to both residential and commercial needs, providing users with efficient heating capabilities under various conditions.

The VP2000BTC is designed with a powerful 2000-watt output, making it suitable for smaller spaces or specific zones within larger environments. It boasts a sleek, modern design that allows for easy integration into any setting, whether it’s a living room, office, or workshop. One of its key features is the advanced thermostat control, which enables precise temperature regulation. This not only enhances user comfort but also contributes to energy efficiency by ensuring that the heating system operates only when necessary.

On the other hand, the VP2800BTC steps up the power to an impressive 2800 watts, making it ideal for larger spaces requiring a more robust heating solution. This model incorporates a multi-functional control panel that allows the user to set timers and customize heating schedules. By doing so, users can optimize their energy consumption, leading to cost savings over time.

Both units utilize infrared heating technology, which offers several advantages over traditional heating methods. Infrared heating warms objects and surfaces directly rather than heating the air, resulting in quicker and more efficient warmth. This technology minimizes heat loss, ensuring that energy is used effectively and providing immediate comfort.

Another noteworthy characteristic of the VP2000BTC and VP2800BTC is their emphasis on safety. Each model comes equipped with overheat protection and a tip-over switch, which provides peace of mind, especially in households with children or pets. Additionally, their lightweight design allows for easy transport and repositioning, making them versatile solutions for various applications.

In summary, the Vanguard Heating VP2000BTC and VP2800BTC are excellent choices for those seeking effective and efficient heating solutions. With their advanced features, precision control, and infrared technology, they stand out as practical options for enhancing comfort in any environment.