Vanguard Heating VP2800BTC Ventilation Air From Outdoors, Ventilation Air from Outdoors

Page 8

AIR FOR COMBUSTION AND VENTILATION

Continued

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code NFPA 54/ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat-controlled power vent. Heated air entering the attic will activate the power vent.

Ventilated

Outlet Attic

Air

Outlet

 

Air

To Attic

 

To

Crawl

Space

Inlet

Air

Inlet Air

 

Ventilated

 

 

Crawl Space

 

 

Figure 3 - Ventilation Air from Outdoors

8

103876

Image 8
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety InformationSafety Features Product IdentificationLocal Codes Unpacking Providing Adequate Ventilation AIR for Combustion Ventilation Determining if You Have a Confined or Unconfined Space AIR for Combustion and VentilationDetermining AIR Flow for Heater Location Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Ventilation Air from OutdoorsInstalling To Wall Installation ItemsCheck GAS Type Locating HeaterAttaching Thermostat Sensing Bulb Thermostat Sensing BulbLocating Thermostat Sensing Bulb Installing Heater to Wall WallMounting Bracket Removing Front Panel Of HeaterMarking Screw Locations Maintain minimum clearances shown in . If you canProvide greater clearances from floor and joining wall Attaching Mounting Bracket To WallInstalling Bottom Mounting Screws Placing Heater On Mounting BracketConnecting To GAS SupplyConnections Pressure Testing GAS Supply Piping SystemChecking GAS Pressure Testing Heater GAS Connections CheckingFor Your Safety Read Before Lighting Operating HeaterOperating Heater Shutting Off Burner Only pilot stays lit Manual Lighting ProcedureShutting Off Heater Inspecting Burner Pilot Flame PatternBurner Flame Pattern Correct Burner Flame PatternCleaning and Maintenance Trouble Shooting Observed Possible Problem Cause RemedyODS/PILOT and Burner CabinetProblem Cause Observed Possible RemedyCleaning and Mainte TROUBLE- ShootingTrouble Shooting VP2000BTC VP2800BTC Technical ServiceService Hints Parts Not Under Warranty Service Publications Replacement PartsParts Under Warranty VP2000BTC VP2800BTC Parts List KEY Part Number for VP2000BTC VP2800BTC Description QTYAccessories Floor Mounting StandModel VP2000BTC GA4000B Model VP2800BTC GA4010B Manual Shutoff103876 Warranty Information Limited Warranty VENT-FREE Residential GAS Heaters