INSPECTING BURNER

Check pilot flame pattern and burner flame pattern often.

PILOT FLAME PATTERN

Figure 19 shows a correct pilot flame pattern. Figure 20 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.

Thermocouple

Pilot Burner

 

Figure 19 - Correct Pilot Flame Pattern

Thermocouple

Pilot Burner

 

Figure 20 - Incorrect Pilot Flame Pattern

If pilot flame pattern is incorrect, as shown in Figure 20

turn heater off (see To Turn Off Gas to Appliance, page 19).

see Troubleshooting, pages 22 through 25

103876

Image 20
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety InformationSafety Features Product IdentificationLocal Codes UnpackingProviding Adequate Ventilation AIR for CombustionVentilation Determining if You Have a Confined or Unconfined Space AIR for Combustion and VentilationDetermining AIR Flow for Heater Location Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Ventilation Air from OutdoorsInstalling To Wall Installation ItemsCheck GAS Type Locating HeaterAttaching Thermostat Sensing Bulb Thermostat Sensing BulbLocating Thermostat Sensing Bulb Installing Heater to Wall WallMounting Bracket Removing Front Panel Of HeaterMarking Screw Locations Maintain minimum clearances shown in . If you canProvide greater clearances from floor and joining wall Attaching Mounting Bracket To WallInstalling Bottom Mounting Screws Placing Heater On Mounting BracketConnecting To GAS SupplyConnections Pressure Testing GAS Supply Piping SystemChecking GAS Pressure Testing Heater GAS Connections Checking For Your Safety Read Before Lighting Operating HeaterOperating Heater Shutting Off Burner Only pilot stays lit Manual Lighting ProcedureShutting Off Heater Inspecting Burner Pilot Flame PatternBurner Flame Pattern Correct Burner Flame PatternCleaning and Maintenance Trouble Shooting Observed Possible Problem Cause RemedyODS/PILOT and Burner CabinetProblem Cause Observed Possible RemedyCleaning and Mainte TROUBLE- ShootingTrouble Shooting VP2000BTC VP2800BTC Technical ServiceService Hints Parts Not Under Warranty Service Publications Replacement PartsParts Under Warranty VP2000BTC VP2800BTC Parts List KEY Part Number for VP2000BTC VP2800BTC Description QTYAccessories Floor Mounting StandModel VP2000BTC GA4000B Model VP2800BTC GA4010B Manual Shutoff103876 Warranty Information Limited Warranty VENT-FREE Residential GAS Heaters