A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your build- ing.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above.

2.Make sure manual shutoff valve is fully open.

3. Turn control knob clockwise Clockwise to the OFF position.

Ignitor Button

 

Control Knob

 

 

TO

ILP

LO

OFF

 

 

HI

 

IGNITOR

Figure 17 - Control Knob In The OFF Position

Continued

103876

17

Image 17
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information ContentsSafety Product Identification FeaturesLocal Codes UnpackingProviding Adequate Ventilation AIR for CombustionVentilation Determining if You Have a Confined or Unconfined Space AIR for Combustion and VentilationDetermining AIR Flow for Heater Location Ventilation Air From Inside Building Ventilation AIRVentilation Air from Outdoors Ventilation Air From OutdoorsInstallation Items Installing To WallCheck GAS Type Locating HeaterAttaching Thermostat Sensing Bulb Thermostat Sensing BulbLocating Thermostat Sensing Bulb Wall Installing Heater to WallMounting Bracket Removing Front Panel Of HeaterMaintain minimum clearances shown in . If you can Marking Screw LocationsProvide greater clearances from floor and joining wall Attaching Mounting Bracket To WallPlacing Heater On Mounting Bracket Installing Bottom Mounting ScrewsSupply Connecting To GASConnections Pressure Testing GAS Supply Piping SystemChecking GAS Checking Pressure Testing Heater GAS ConnectionsOperating Heater For Your Safety Read Before LightingOperating Heater Shutting Off Burner Only pilot stays lit Manual Lighting ProcedureShutting Off Heater Pilot Flame Pattern Inspecting BurnerCorrect Burner Flame Pattern Burner Flame PatternObserved Possible Problem Cause Remedy Cleaning and Maintenance Trouble ShootingODS/PILOT and Burner CabinetObserved Possible Remedy Problem CauseTROUBLE- Shooting Cleaning and MainteTrouble Shooting VP2000BTC VP2800BTC Technical ServiceService Hints Parts Not Under Warranty Service Publications Replacement PartsParts Under Warranty VP2000BTC VP2800BTC KEY Part Number for VP2000BTC VP2800BTC Description QTY Parts ListFloor Mounting Stand AccessoriesModel VP2000BTC GA4000B Model VP2800BTC GA4010B Manual Shutoff103876 Limited Warranty VENT-FREE Residential GAS Heaters Warranty Information

VP2800BTC, VP2000BTC specifications

Vanguard Heating has made notable strides in the heating solutions market with its cutting-edge models, the VP2000BTC and VP2800BTC. These units cater to both residential and commercial needs, providing users with efficient heating capabilities under various conditions.

The VP2000BTC is designed with a powerful 2000-watt output, making it suitable for smaller spaces or specific zones within larger environments. It boasts a sleek, modern design that allows for easy integration into any setting, whether it’s a living room, office, or workshop. One of its key features is the advanced thermostat control, which enables precise temperature regulation. This not only enhances user comfort but also contributes to energy efficiency by ensuring that the heating system operates only when necessary.

On the other hand, the VP2800BTC steps up the power to an impressive 2800 watts, making it ideal for larger spaces requiring a more robust heating solution. This model incorporates a multi-functional control panel that allows the user to set timers and customize heating schedules. By doing so, users can optimize their energy consumption, leading to cost savings over time.

Both units utilize infrared heating technology, which offers several advantages over traditional heating methods. Infrared heating warms objects and surfaces directly rather than heating the air, resulting in quicker and more efficient warmth. This technology minimizes heat loss, ensuring that energy is used effectively and providing immediate comfort.

Another noteworthy characteristic of the VP2000BTC and VP2800BTC is their emphasis on safety. Each model comes equipped with overheat protection and a tip-over switch, which provides peace of mind, especially in households with children or pets. Additionally, their lightweight design allows for easy transport and repositioning, making them versatile solutions for various applications.

In summary, the Vanguard Heating VP2000BTC and VP2800BTC are excellent choices for those seeking effective and efficient heating solutions. With their advanced features, precision control, and infrared technology, they stand out as practical options for enhancing comfort in any environment.