Vanguard Heating VP16A, VP26TA VN30A, VP26A, VP22ITA Checking GAS Connections, Gas Connection

Page 12

INSTALLATION

Continued

CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of large enough diameter to allow proper gas volume to heater. If pipe is too small, undue loss of volume will occur.

Typical Inlet Pipe Diameters

VN18A, VN18TA, VP16A, VP16TA, and

VP16ITA - 3/8" or greater

VN30A, VN30TA, VP26A, VP26TA, and

VP22ITA - 1/2" or greater

Installation must include equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 15).

IMPORTANT: Install an equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance.

Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from go- ing into pipe. Excess sealant in pipe could result in clogged heater valves.

WARNING: Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.

Install sediment trap in supply line as shown in Figure 15. Locate sediment trap where it is within reach for cleaning. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.

IMPORTANT: Hold the pressure regulator with wrench when connecting it to gas piping and/or fittings. Do not over tighten pipe connection to regulator. The regulator body could be damaged.

Pressure

 

 

 

Regulator

 

 

3/8" NPT

Regulator

 

 

 

 

Pipe

Bracket

 

 

Nipple

Heater

 

 

Ground

Cabinet

 

 

Joint

Connection*

Bushing to

 

Valve *

 

Tee Joint

 

Union

 

Reducer

 

Equipment

 

 

Shutoff

Gauge

1/8" NPT

 

Natural Gas

1/8" NPT

 

 

 

 

3"

From Gas

 

Plug Tap

 

Test

Min. Meter (7" W.C.

 

 

 

to 10.5" W.C.

 

 

 

 

 

Tee

Pipe Cap

 

Pressure)

 

Joint

Nipple

 

Propane/LP

From External

Sediment Trap Regulator

(11" W.C. to 14"

W.C. Pressure)

*A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 33.

Figure 15 - Gas Connection

CHECKING GAS CONNECTIONS

WARNING: Test all gas pip- ing and connections, internal and external to unit, for leaks after installing or servicing. Cor- rect all leaks at once.

WARNING: Never use an open flame to check for a leak. Apply a noncorrosive leak de- tection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.

CAUTION: For propane/LP gas, make sure external regula- tor has been installed between propane/LP supply and heater. See guidelines under Connect- ing to Gas Supply, page 11.

12

www.desatech.com

113052-01A

Image 12
Contents VN30A, VN30TA, VP16ITA, VP22ITA Model VN30A ShownTable of Contents Safety Information Product Features Local CodesProduct Identification UnpackingAIR for Combustion Ventilation Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation AIR Ventilation Air From Inside BuildingInstallation Installation ItemsCheck GAS Type Locating HeaterInstalling Heater to Wall Thermostat Sensing BulbMounting Bracket Removing Front Panel Of HeaterMethods For Attaching Mounting Bracket To Wall Marking Screw LocationsPlaque Heater Installing Bottom Mounting Screws Placing Heater On Mounting BracketConnecting to GAS Supply Mounting Base Feet to Floor Where required by local codeMounting Heater to Floor Mounting Base Feet to HeaterChecking GAS Connections Gas ConnectionPressure Testing Gas Supply Piping System Pressurize supply piping system by eitherNON-THERMOSTAT Models For Your Safety Read Before Lighting Operating HeaterLighting Instructions Manual Lighting Procedure Thermostat Models For Your Safety Read Before LightingTo Select Heating Level To Turn OFF GAS To ApplianceVP16TA VP26TA Thermostat Operation PlaqueInspecting Heater Pilot Flame PatternBurner Flame Pattern Cleaning Maintenance Cleaning Burner Pilot AIR InletODS/PILOT and Burner CabinetTroubleshooting Observed Problem Possible Cause RemedyPress in control knob fully Gas leak. See Warning Metal expanding while heating or contracting while coolingSpecifications Illustrated Parts Breakdown Cabinet Body ModelsParts List Cabinet Body Models VP16ITA and VP22ITA KEY Part Number VP16ITA VP22ITA Description Illustrated Parts Breakdown and Parts List Burner Assembly Models VP16A and VN18ABurner Assembly Models VP26A and VN30A ODS/Pilot Burner Assembly VP26A, VN30ABurner Assembly Models VP16ITA and VP22ITA Burner Assembly VP16ITABurner Assembly Models VP16TA, VN18TA, VP26TA, and VN30TA Replacement Parts Service Publications Service HintsTechnical Service Parts Under WarrantyAccessories Parts CentralFAN Kits GA3250T Equipment Shutoff Valve GA5010113052-01A 113052-01A Warranty Information Keep this WarrantyLimited Warranty Vanguard VENT-FREE Infrared GAS Heaters