Vanguard Heating VP16ITA, VP26A Local Codes, Product Identification, Unpacking, Product Features

Page 4

SAFETY INFORMATION

Continued

5.Always run heater with plaque control knob at the 1, 2, 3, or 4 locked positions. Never set control knob between locked positions. Poor combustion and higher levels of carbon mon- oxide may result.

6.This heater needs fresh, outside air ventila- tion to run properly. This heater has an Oxy- gen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for Com- bustion and Ventilation, pages 5 through 7.

7.If heater shuts off, do not relight until you pro- vide fresh, outside air. If heater keeps shut- ting off, have it serviced.

8.Do not run heater

where flammable liquids or vapors are used or stored

under dusty conditions

9.Do not use heater if any part has been under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.

10.Turn off and unplug heater and let cool be- fore servicing. Only a qualified service per- son should service and repair heater.

11.Operating heater above elevations of 4,500 feet could cause pilot outage.

12.To prevent performance problems, do not use propane/LP fuel tank of less than 100 lbs. ca- pacity.

13.Before using furniture polish, wax, carpet cleaner, or similar products, turn heater off. If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture.

14.Provide adequate clearances around air open- ings.

LOCAL CODES

Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANSI Z223.1/NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

PRODUCT

IDENTIFICATION

Ignitor Button

Control

 

Knob

Grill

Guard

Plaque

Front Panel

Heater Cabinet

Figure 1 - Vent-Free Gas Heater

UNPACKING

1.Remove heater from carton.

2.Remove all protective packaging applied to heater for shipment.

3.Check heater for any shipping damage. If heater is damaged, promptly return to where you bought heater.

PRODUCT FEATURES

SAFETY DEVICE

This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/ pilot is a required feature for vent-free room heat- ers. The ODS/pilot shuts off the heater if there is not enough fresh air.

IGNITION SYSTEM

This heater has an electronic ignitor to light heater fuel supply.

THERMOSTATIC HEAT CONTROL

(Thermostat Models Only)

Thermostat models have a thermostat sensing bulb and a control valve. This results in the greatest heater comfort. This can also result in lower gas bills.

4

www.desatech.com

113052-01A

Image 4
Contents VN30A, VN30TA, VP16ITA, VP22ITA Model VN30A ShownTable of Contents Safety Information Product Features Local CodesProduct Identification UnpackingProviding Adequate Ventilation AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation AIR Ventilation Air From Inside BuildingInstallation Installation ItemsCheck GAS Type Locating HeaterInstalling Heater to Wall Thermostat Sensing BulbMounting Bracket Removing Front Panel Of HeaterMarking Screw Locations Methods For Attaching Mounting Bracket To WallPlaque Heater Installing Bottom Mounting Screws Placing Heater On Mounting BracketConnecting to GAS Supply Mounting Base Feet to Floor Where required by local codeMounting Heater to Floor Mounting Base Feet to HeaterChecking GAS Connections Gas ConnectionPressure Testing Gas Supply Piping System Pressurize supply piping system by eitherOperating Heater NON-THERMOSTAT Models For Your Safety Read Before LightingLighting Instructions Manual Lighting Procedure Thermostat Models For Your Safety Read Before LightingTo Select Heating Level To Turn OFF GAS To ApplianceVP16TA VP26TA Thermostat Operation PlaquePilot Flame Pattern Inspecting HeaterBurner Flame Pattern Cleaning Maintenance Cleaning Burner Pilot AIR InletODS/PILOT and Burner CabinetTroubleshooting Observed Problem Possible Cause RemedyPress in control knob fully Gas leak. See Warning Metal expanding while heating or contracting while coolingSpecifications Illustrated Parts Breakdown Cabinet Body ModelsParts List Cabinet Body Models VP16ITA and VP22ITA KEY Part Number VP16ITA VP22ITA Description Illustrated Parts Breakdown and Parts List Burner Assembly Models VP16A and VN18ABurner Assembly Models VP26A and VN30A ODS/Pilot Burner Assembly VP26A, VN30ABurner Assembly Models VP16ITA and VP22ITA Burner Assembly VP16ITABurner Assembly Models VP16TA, VN18TA, VP26TA, and VN30TA Replacement Parts Service Publications Service HintsTechnical Service Parts Under WarrantyAccessories Parts CentralFAN Kits GA3250T Equipment Shutoff Valve GA5010113052-01A 113052-01A Keep this Warranty Warranty InformationLimited Warranty Vanguard VENT-FREE Infrared GAS Heaters