Vanguard Heating VP16TA, VP26TA VN30A, VP26A, VP22ITA, VP16A, VP16ITA, VN30TA, VN18TA Specifications

Page 23

SPECIFICATIONS

 

VP16A, VP16TA

VP16ITA

VP26A, VP26TA

VP22ITA

Btu (Variable)

6,000/11,000/16,000

6,000/16,000

6,000/16,000/26,000

6,500/22,000

Type Gas

Propane/LP Only

Propane/LP Only

Propane/LP Only

Propane/LP Only

Ignition

Electronic

Electronic

Electronic

Electronic

Pressure Regulator Setting 8" W.C.

8" W.C.

8" W.C.

8" W.C.

Inlet Gas Pressure* (in. of water)

 

 

 

Maximum

14"

14"

14"

14"

Minimum

11"

11"

11"

11"

Dimensions, Inches (H x W x D)

 

 

 

Heater

24.25 x 18.25 x 7

24.25 x 18.25 x 7

24.25 x 25.75 x 7

24.25 x 25.75 x 7

Carton

26.25 x 21.25 x 9

26.25 x 21.25 x 9

26.25 x 29 x 9

26.25 x 29 x 9

Weight (pounds)

 

 

 

 

Heater

20

20

28

28

Shipping

25

25

33

33

Note: Dimensions listed are outer most points on the heater (includes control knobs and grill).

* For purposes of input adjustment.

 

 

 

 

VN18A, VN18TA

VN30A, VN30TA

 

Btu (Variable)

6,600/12,000/18,000

6,600/18,000/30,000

 

Type Gas

Natural Only

Natural Only

 

 

Ignition

Electronic

Electronic

 

 

Pressure Regulator Setting

6" W.C.

6" W.C.

 

 

Inlet Gas Pressure* (in. of water)

 

 

 

Maximum

10.5"

10.5"

 

 

Minimum

7"

7"

 

 

Dimensions, Inches (H x W x D)

 

 

 

Heater

24.25 x 18.25 x 7

24.25 x 25.75 x 7

 

 

Carton

26.25 x 21.25 x 9

26.25 x 29 x 9

 

 

Weight (pounds)

 

 

 

 

Heater

20

28

 

 

Shipping

25

33

 

 

Note: Dimensions listed are outer most points on the heater (includes control knobs and grill).

* For purposes of input adjustment.

113052-01A

www.desatech.com

23

Image 23
Contents Model VN30A Shown VN30A, VN30TA, VP16ITA, VP22ITATable of Contents Safety Information Unpacking Product FeaturesLocal Codes Product IdentificationDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationProviding Adequate Ventilation Ventilation Air From Inside Building Ventilation AIRLocating Heater InstallationInstallation Items Check GAS TypeRemoving Front Panel Of Heater Installing Heater to WallThermostat Sensing Bulb Mounting BracketPlaque Heater Methods For Attaching Mounting Bracket To WallMarking Screw Locations Placing Heater On Mounting Bracket Installing Bottom Mounting ScrewsMounting Base Feet to Heater Connecting to GAS SupplyMounting Base Feet to Floor Where required by local code Mounting Heater to FloorGas Connection Checking GAS ConnectionsPressurize supply piping system by either Pressure Testing Gas Supply Piping SystemLighting Instructions NON-THERMOSTAT Models For Your Safety Read Before LightingOperating Heater To Turn OFF GAS To Appliance Manual Lighting ProcedureThermostat Models For Your Safety Read Before Lighting To Select Heating LevelVP16TA VP26TA Plaque Thermostat OperationBurner Flame Pattern Inspecting HeaterPilot Flame Pattern Cabinet Cleaning MaintenanceCleaning Burner Pilot AIR Inlet ODS/PILOT and BurnerObserved Problem Possible Cause Remedy TroubleshootingPress in control knob fully Metal expanding while heating or contracting while cooling Gas leak. See WarningSpecifications Cabinet Body Models Illustrated Parts BreakdownParts List Cabinet Body Models VP16ITA and VP22ITA KEY Part Number VP16ITA VP22ITA Description Burner Assembly Models VP16A and VN18A Illustrated Parts Breakdown and Parts ListODS/Pilot Burner Assembly VP26A, VN30A Burner Assembly Models VP26A and VN30ABurner Assembly VP16ITA Burner Assembly Models VP16ITA and VP22ITABurner Assembly Models VP16TA, VN18TA, VP26TA, and VN30TA Parts Under Warranty Replacement PartsService Publications Service Hints Technical ServiceEquipment Shutoff Valve GA5010 AccessoriesParts Central FAN Kits GA3250T113052-01A 113052-01A Limited Warranty Vanguard VENT-FREE Infrared GAS Heaters Warranty InformationKeep this Warranty