Vanguard Heating VP16ITA, VP26TA VN30A, VP26A, VP22ITA Pressure Testing Gas Supply Piping System

Page 13

INSTALLATION

Continued

Pressure Testing Gas Supply Piping System

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)

1.Disconnect appliance with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator.

2.Cap off open end of gas pipe where equip- ment shutoff valve was connected.

3.Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve lo- cated on or near gas meter for natural gas, or using compressed air.

4.Check all joints of gas supply piping system. Apply a noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Reconnect heater and equipment shutoff valve to gas supply. Check reconnected fittings for leaks.

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.

Close equipment shutoff valve (see Figure 16).

2.

Pressurize supply piping system by either

 

opening propane/LP supply tank valve for

 

propane/LP gas or opening main gas valve lo-

 

cated on or near gas meter for natural gas, or

 

using compressed air.

3.

Check all joints from gas meter for natural

 

gas (see Figure 17) or propane/LP supply tank

4.Check all joints from equipment shutoff valve to thermostat gas valve (see Figure 17 or 18). Apply a noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light heater (see Operating Heater, pages 14 through 17). Check all other internal joints for leaks.

7.Turn off heater (see To Turn Off Gas to Appli- ance, page 15 or 17 depending on your model).

8.Replace front panel.

 

Open

Equipment

N

POSIT

Shutoff Valve

 

 

O

 

Closed

 

PO

Figure 16 - Equipment Shutoff Valve

Thermostat Gas Valve

Gas

Meter

Equipment

Shutoff

Valve

Figure 17 - Checking Gas Joints for

Natural Gas

Thermostat Gas Valve

for propane/LP gas, to equipment shutoff

valve (see Figure 18). Apply a noncorrosive

leak detection fluid to all joints. Bubbles form-

ing show a leak.

4. Correct all leaks at once.

Pressure Testing Heater Gas Connections

1.

Open equipment shutoff valve (see Figure 16).

2.

For natural gas open main gas valve located

 

on or near gas meter. For propane/LP gas open

 

propane/LP supply tank valve.

Propane/LP Supply Tank

Equipment

Shutoff

Valve

3. Make sure control knob of heater is in the OFF

position.

Figure 18 - Checking Gas Joints for

Propane/LP Gas

113052-01A

www.desatech.com

13

Image 13
Contents Model VN30A Shown VN30A, VN30TA, VP16ITA, VP22ITATable of Contents Safety Information Local Codes Product FeaturesProduct Identification UnpackingProviding Adequate Ventilation AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Inside Building Ventilation AIRInstallation Items InstallationCheck GAS Type Locating HeaterThermostat Sensing Bulb Installing Heater to WallMounting Bracket Removing Front Panel Of HeaterMarking Screw Locations Methods For Attaching Mounting Bracket To WallPlaque Heater Placing Heater On Mounting Bracket Installing Bottom Mounting ScrewsMounting Base Feet to Floor Where required by local code Connecting to GAS SupplyMounting Heater to Floor Mounting Base Feet to HeaterGas Connection Checking GAS ConnectionsPressurize supply piping system by either Pressure Testing Gas Supply Piping SystemOperating Heater NON-THERMOSTAT Models For Your Safety Read Before LightingLighting Instructions Thermostat Models For Your Safety Read Before Lighting Manual Lighting ProcedureTo Select Heating Level To Turn OFF GAS To ApplianceVP16TA VP26TA Plaque Thermostat OperationPilot Flame Pattern Inspecting HeaterBurner Flame Pattern Cleaning Burner Pilot AIR Inlet Cleaning MaintenanceODS/PILOT and Burner CabinetObserved Problem Possible Cause Remedy TroubleshootingPress in control knob fully Metal expanding while heating or contracting while cooling Gas leak. See WarningSpecifications Cabinet Body Models Illustrated Parts BreakdownParts List Cabinet Body Models VP16ITA and VP22ITA KEY Part Number VP16ITA VP22ITA Description Burner Assembly Models VP16A and VN18A Illustrated Parts Breakdown and Parts ListODS/Pilot Burner Assembly VP26A, VN30A Burner Assembly Models VP26A and VN30ABurner Assembly VP16ITA Burner Assembly Models VP16ITA and VP22ITABurner Assembly Models VP16TA, VN18TA, VP26TA, and VN30TA Service Publications Service Hints Replacement PartsTechnical Service Parts Under WarrantyParts Central AccessoriesFAN Kits GA3250T Equipment Shutoff Valve GA5010113052-01A 113052-01A Keep this Warranty Warranty InformationLimited Warranty Vanguard VENT-FREE Infrared GAS Heaters