Vanguard Heating VN30TA, VP26TA VN30A, VP26A To Select Heating Level, To Turn OFF GAS To Appliance

Page 15

OPERATING HEATER

Continued

TO SELECT

HEATING LEVEL

WARNING: When running heater, set control knob at LOW, MEDIUM, or HIGH locked posi- tions. Never set control knob between locked positions. Poor combustion and higher levels of carbon monoxide may result.

CAUTION: Do not try to ad- just heating levels by using the equipment shutoff valve.

Slightly press in control knob and turn coun-

terclockwise to the LOW, MED, or HI positions (see Figure 21).

IMPORTANT: Release downward pressure while turning control knob. Control knob will lock at the desired position.

Control

VN18A

VN30A

Knob

VP16A

VP26A

 

 

 

H

 

 

 

 

 

 

I

 

 

 

MED

 

 

 

 

 

 

LOW

 

 

 

 

 

 

 

PILO

T

OFF

 

 

 

 

 

 

 

 

LOW

HI

 

 

 

 

 

MED

 

 

 

 

 

 

LOW

 

 

FFO

 

 

 

PILOT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MED

 

 

 

 

FFO

 

 

HI

 

 

 

 

 

 

 

 

 

 

TO

 

 

M

ED

 

W

LIP

 

 

 

 

 

LO

 

 

 

 

 

 

 

 

 

HI

ILO

 

 

LO

 

 

P

 

W

 

 

 

 

T

MED

 

 

 

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

IH

 

 

OFF

Figure 21 - Burner Patterns for Non-

Thermostat Models

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1. Turn control knob clockwise to the OFF position.

2.Turn off all electric power to the appliance if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise to the PILOT position.

MANUAL LIGHTING

PROCEDURE

1.Remove front panel (see Figure 7, page 8).

2.Follow steps 1 through 5 under Lighting In- structions, page 14.

3.With control knob pressed in, strike match. Hold match to pilot until pilot lights.

4.Keep control knob pressed in for 30 sec- onds after lighting pilot. After 30 seconds, release control knob. Now follow step 8, under Lighting Instructions, page 14.

5.Replace front panel.

THERMOSTAT MODELS

FOR YOUR SAFETY READ

BEFORE LIGHTING

WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result causing property damage, per- sonal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service tech- nician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified ser- vice technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

113052-01A

www.desatech.com

15

Image 15
Contents Model VN30A Shown VN30A, VN30TA, VP16ITA, VP22ITATable of Contents Safety Information Unpacking Product FeaturesLocal Codes Product IdentificationAIR for Combustion Ventilation Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Inside Building Ventilation AIRLocating Heater InstallationInstallation Items Check GAS TypeRemoving Front Panel Of Heater Installing Heater to WallThermostat Sensing Bulb Mounting BracketMethods For Attaching Mounting Bracket To Wall Marking Screw LocationsPlaque Heater Placing Heater On Mounting Bracket Installing Bottom Mounting ScrewsMounting Base Feet to Heater Connecting to GAS SupplyMounting Base Feet to Floor Where required by local code Mounting Heater to FloorGas Connection Checking GAS ConnectionsPressurize supply piping system by either Pressure Testing Gas Supply Piping SystemNON-THERMOSTAT Models For Your Safety Read Before Lighting Operating HeaterLighting Instructions To Turn OFF GAS To Appliance Manual Lighting ProcedureThermostat Models For Your Safety Read Before Lighting To Select Heating LevelVP16TA VP26TA Plaque Thermostat OperationInspecting Heater Pilot Flame PatternBurner Flame Pattern Cabinet Cleaning MaintenanceCleaning Burner Pilot AIR Inlet ODS/PILOT and BurnerObserved Problem Possible Cause Remedy TroubleshootingPress in control knob fully Metal expanding while heating or contracting while cooling Gas leak. See WarningSpecifications Cabinet Body Models Illustrated Parts BreakdownParts List Cabinet Body Models VP16ITA and VP22ITA KEY Part Number VP16ITA VP22ITA Description Burner Assembly Models VP16A and VN18A Illustrated Parts Breakdown and Parts ListODS/Pilot Burner Assembly VP26A, VN30A Burner Assembly Models VP26A and VN30ABurner Assembly VP16ITA Burner Assembly Models VP16ITA and VP22ITABurner Assembly Models VP16TA, VN18TA, VP26TA, and VN30TA Parts Under Warranty Replacement PartsService Publications Service Hints Technical ServiceEquipment Shutoff Valve GA5010 AccessoriesParts Central FAN Kits GA3250T113052-01A 113052-01A Warranty Information Keep this WarrantyLimited Warranty Vanguard VENT-FREE Infrared GAS Heaters