Vanguard Heating VP16A, VP26TA VN30A, VP26A, VP22ITA, VP16ITA, VP16TA Press in control knob fully

Page 21

TROUBLESHOOTING

 

 

Continued

 

 

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

ODS/pilot lights but flame goes

1. Control knob not fully pressed in

1.

Press in control knob fully

out when control knob is re-

2. Control knob not pressed in

2. After ODS/pilot lights, keep con-

leased

 

long enough

 

trol knob pressed in 30 seconds

 

3.

Equipment shutoff valve not

3.

Fully open equipment shutoff

 

 

fully open

 

valve

 

4.

Thermocouple connection

4.

Hand tighten until snug, then

 

 

loose at control valve

 

tighten 1/4 turn more

 

5.

Pilot flame not touching ther-

5.

A) Contact local natural or

 

 

mocouple, which allows ther-

 

propane/LP gas company

 

 

mocouple to cool, causing pi-

 

B) Clean ODS/pilot (see

 

 

lot flame to go out. This prob-

 

Cleaning and Maintenance,

 

 

lem could be caused by one or

 

page 19) or replace ODS/pi-

 

 

both of the following:

 

lot assembly

 

 

A) Low gas pressure

 

 

 

 

B) Dirty or partially clogged

 

 

 

 

ODS/pilot

 

 

 

6.

Thermocouple damaged

6.

Replace pilot assembly

 

7.

Control valve damaged

7.

Replace control valve

 

8.

Safety interlock system has

8.

Wait one minute for safety in-

 

 

been triggered (thermostat

 

terlock system to reset. Repeat

 

 

models only)

 

ignition operation

 

 

 

 

Burner(s) does not light after

1. Burner orifice(s) is clogged

1.

Clean burner orifice(s) (see

ODS/pilot is lit

 

 

 

Cleaning and Maintenance,

 

 

 

 

page 19) or replace burner

 

 

 

 

orifice(s)

 

2.

Inlet gas pressure is too low

2.

Contact local natural or pro-

 

 

 

 

pane/LP gas company

 

 

 

 

Delayed ignition of burner(s)

1. Manifold pressure is too low

1.

Contact local natural or pro-

 

 

 

 

pane/LP gas company

 

2.

Burner orifice(s) is clogged

2.

Clean burner orifice(s) (see

 

 

 

 

Cleaning and Maintenance,

 

 

 

 

page 19) or replace burner

 

 

 

 

orifice(s)

 

 

 

 

Burner backfiring during com-

1. Burner orifice(s) is clogged or

1.

Clean burner orifice(s) (see

bustion

 

damaged

 

Cleaning and Maintenance,

 

 

 

 

page 19) or replace burner

 

2.

Burner damaged

 

orifice(s)

 

3.

Gas regulator defective

2.

Replace burner

 

 

 

3.

Replace gas regulator

 

 

 

 

Burner plaque(s) does not glow

1. Plaque damaged

1.

Replace burner

 

2.

Inlet gas pressure is too low

2.

Contact local natural or pro-

 

 

 

 

pane/LP gas company

 

3.

Control knob set between

3.

Turn control knob until it

 

 

locked positions

 

locks at desired setting

 

 

 

 

Slight smoke or odor during ini-

1. Residues from manufacturing

1.

Problem will stop after a few

tial operation

 

processes

 

hours of operation

113052-01A

www.desatech.com

21

Image 21
Contents Model VN30A Shown VN30A, VN30TA, VP16ITA, VP22ITATable of Contents Safety Information Local Codes Product FeaturesProduct Identification UnpackingAIR for Combustion Ventilation Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Inside Building Ventilation AIRInstallation Items InstallationCheck GAS Type Locating HeaterThermostat Sensing Bulb Installing Heater to WallMounting Bracket Removing Front Panel Of HeaterMethods For Attaching Mounting Bracket To Wall Marking Screw LocationsPlaque Heater Placing Heater On Mounting Bracket Installing Bottom Mounting ScrewsMounting Base Feet to Floor Where required by local code Connecting to GAS SupplyMounting Heater to Floor Mounting Base Feet to HeaterGas Connection Checking GAS ConnectionsPressurize supply piping system by either Pressure Testing Gas Supply Piping SystemNON-THERMOSTAT Models For Your Safety Read Before Lighting Operating HeaterLighting Instructions Thermostat Models For Your Safety Read Before Lighting Manual Lighting ProcedureTo Select Heating Level To Turn OFF GAS To ApplianceVP16TA VP26TA Plaque Thermostat OperationInspecting Heater Pilot Flame PatternBurner Flame Pattern Cleaning Burner Pilot AIR Inlet Cleaning MaintenanceODS/PILOT and Burner CabinetObserved Problem Possible Cause Remedy TroubleshootingPress in control knob fully Metal expanding while heating or contracting while cooling Gas leak. See WarningSpecifications Cabinet Body Models Illustrated Parts BreakdownParts List Cabinet Body Models VP16ITA and VP22ITA KEY Part Number VP16ITA VP22ITA Description Burner Assembly Models VP16A and VN18A Illustrated Parts Breakdown and Parts ListODS/Pilot Burner Assembly VP26A, VN30A Burner Assembly Models VP26A and VN30ABurner Assembly VP16ITA Burner Assembly Models VP16ITA and VP22ITABurner Assembly Models VP16TA, VN18TA, VP26TA, and VN30TA Service Publications Service Hints Replacement PartsTechnical Service Parts Under WarrantyParts Central AccessoriesFAN Kits GA3250T Equipment Shutoff Valve GA5010113052-01A 113052-01A Warranty Information Keep this WarrantyLimited Warranty Vanguard VENT-FREE Infrared GAS Heaters