Vanguard Heating VP22ITA, VP26TA VN30A Troubleshooting, Observed Problem Possible Cause Remedy

Page 20

TROUBLESHOOTING

Note: All troubleshooting items are listed in order of operation.

WARNING: Turn off and unplug heater and let cool before servic- ing. Only a qualified service person should service and repair heater.

CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/pilot unit.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed

1. Ignitor electrode positioned

1.

Replace pilot assembly

in, there is no spark at ODS/

 

wrong

 

 

pilot

2. Ignitor electrode broken

2.

Replace pilot assembly

 

3.

Ignitor electrode not con-

3.

Reconnect ignitor cable

 

 

nected to ignitor cable

 

 

 

4.

Ignitor cable pinched or wet

4.

Free ignitor cable if pinched

 

 

 

 

by any metal or tubing. Keep

 

 

 

 

ignitor cable dry

 

5.

Broken ignitor cable

5.

Replace ignitor cable

 

6.

Bad ignitor

6.

Replace ignitor

 

7.

Battery not installed, battery

7.

Install new alkaline battery in

 

 

power low, or battery not in-

 

electronic ignitor. Verify bat-

 

 

stalled correctly (electronic ig-

 

tery is installed correctly

 

 

nition models only)

 

 

 

 

 

 

 

When ignitor button is pressed in, there is a spark at ODS/Pilot but no ignition

1.Gas supply turned off or equip- ment shutoff valve closed

2.Control knob not fully pressed in while pressing ignitor but- ton (non-thermostat models only)

Thermostat control knob not fully pressed in while pressing ignitor button (thermostat models only)

3.Air in gas lines when installed

4.Depleted gas supply (propane/ LP gas)

5.ODS/pilot is clogged

6.Gas regulator setting is not correct

7.Thermostat control knob is not in pilot position (thermostat models only)

1.Turn on gas supply or open equipment shutoff valve

2.Turn to PILOT/IGN position. Fully press in control knob while pressing ignitor button (non-thermostat models only) Fully press in thermostat con- trol knob while pressing igni- tor button (thermostat models only)

3.Continue holding down con- trol knob. Repeat igniting op- eration until air is removed

4.Contact local propane/LP gas company

5.Clean ODS/pilot (see Cleaning and Maintenance, page 19) or replace ODS/pilot assembly

6.Replace gas regulator

7.Turn thermostat control knob to pilot position

20

www.desatech.com

113052-01A

Image 20
Contents VN30A, VN30TA, VP16ITA, VP22ITA Model VN30A ShownTable of Contents Safety Information Product Features Local CodesProduct Identification UnpackingDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationProviding Adequate Ventilation Ventilation AIR Ventilation Air From Inside BuildingInstallation Installation ItemsCheck GAS Type Locating HeaterInstalling Heater to Wall Thermostat Sensing BulbMounting Bracket Removing Front Panel Of HeaterPlaque Heater Methods For Attaching Mounting Bracket To WallMarking Screw Locations Installing Bottom Mounting Screws Placing Heater On Mounting BracketConnecting to GAS Supply Mounting Base Feet to Floor Where required by local codeMounting Heater to Floor Mounting Base Feet to HeaterChecking GAS Connections Gas ConnectionPressure Testing Gas Supply Piping System Pressurize supply piping system by eitherLighting Instructions NON-THERMOSTAT Models For Your Safety Read Before LightingOperating Heater Manual Lighting Procedure Thermostat Models For Your Safety Read Before LightingTo Select Heating Level To Turn OFF GAS To ApplianceVP16TA VP26TA Thermostat Operation PlaqueBurner Flame Pattern Inspecting HeaterPilot Flame Pattern Cleaning Maintenance Cleaning Burner Pilot AIR InletODS/PILOT and Burner CabinetTroubleshooting Observed Problem Possible Cause RemedyPress in control knob fully Gas leak. See Warning Metal expanding while heating or contracting while coolingSpecifications Illustrated Parts Breakdown Cabinet Body ModelsParts List Cabinet Body Models VP16ITA and VP22ITA KEY Part Number VP16ITA VP22ITA Description Illustrated Parts Breakdown and Parts List Burner Assembly Models VP16A and VN18ABurner Assembly Models VP26A and VN30A ODS/Pilot Burner Assembly VP26A, VN30ABurner Assembly Models VP16ITA and VP22ITA Burner Assembly VP16ITABurner Assembly Models VP16TA, VN18TA, VP26TA, and VN30TA Replacement Parts Service Publications Service HintsTechnical Service Parts Under WarrantyAccessories Parts CentralFAN Kits GA3250T Equipment Shutoff Valve GA5010113052-01A 113052-01A Limited Warranty Vanguard VENT-FREE Infrared GAS Heaters Warranty InformationKeep this Warranty