Empire Comfort Systems 3)(N, 1, DVD32FP3 GAS Supply, Recommended Gas Pipe Diameter

Page 11

GAS SUPPLY

The gas pipeline can be brought in through the right or left side of the appliance. Consult the current National Fuel Gas Code, ANSI Z223.1 CAN/CGA-B149 (.1 or .2) installation code.

Recommended Gas Pipe Diameter

 

Schedule 40 Pipe

Tubing, Type L

Pipe Length

Inside Diameter

Outside Diameter

 

Nat.

L.P.

Nat.

L.P.

0-10 feet

1/2”

3/8”

1/2”

3/8”

0-3 meters

12.7 mm

9.5 mm

12.7 mm

9.5 mm

10-40 feet

1/2”

1/2”

5/8”

1/2”

4-12 meters

12.7 mm

12.7 mm

15.9 mm

12.7 mm

40-100 feet

1/2”

1/2”

3/4”

1/2”

13-30 meters

12.7 mm

12.7 mm

19 mm

12.7 mm

100-150 feet

3/4”

1/2”

7/8”

3/4”

31-46 meters

19 mm

12.7 mm

22.2 mm

19 mm

Note: Never use plastic pipe. Check to confirm whether your local codes allow copper tubing or galvanized.

Note: Since some municipalities have additional local codes, it is always best to consult your local authority and installation code.

The use of the following gas connectors is recommended:

ANS Z21.24Appliance Connectors of Corrugated MetalTubing and Fittings.

ANS Z21.45 Assembled Flexible Appliance Connectors of Other Than All-Metal Construction

The above connectors may be used if acceptable by the authority having jurisdiction.The state of Massachusetts requires that a flexible appliance connector cannot exceed three feet in length.

Figure 6

 

Gas Supply Pressure (inches w.c.)

 

 

 

 

 

Minimum

Normal

Maximum

 

 

 

 

Natural Gas

4.5"

7.0"

14.0"

 

 

 

 

LP (Propane)

10.8"

11.0"

14.0"

 

 

 

 

 

Manifold Pressure (inches w.c.)

 

 

 

 

 

Normal (HI)

 

 

 

 

Natural Gas

 

3.5"

 

 

 

 

 

LP (Propane)

 

10.0"

 

 

 

 

 

Installing a New Main Gas Cock

Each appliance should have its own manual gas cock.

A manual main gas cock should be located in the vicinity of the unit. Where none exists, or where its size or location is not ad- equate, contact your local authorized installer for installation or relocation.

Compounds used on threaded joints of gas piping shall be resistant to the action of liquefied petroleum gases. The gas lines must be checked for leaks by the installer. This should be done with a soap solution watching for bubbles on all exposed connections, and if unexposed, a pressure test should be made.

Never use an exposed flame to check for leaks. Appliance must be disconnected from piping at inlet of control valve and pipe capped or plugged for pressure test. Never pressure test with appliance connected; control valve will sustain damage!

NOTE: The millivolt gas controls are equipped with a captured screw type pressure test point, therefore it is not necessary to provide a 1/8" test point up stream of the control.

Ondirectignitionvalves,hexplugsmaybereplacedwithhosefittings for pressure checks, then reinstalled before operating fireplace.

When using copper or flex connector use only approved fittings.

The appliance and it’s individual shut off valve must be disconnected from supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).

The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).

Attention! If one of the procedures results in pressures in excess of 1/2 psig (14" w.c.) (3.5 kPa) on the fireplace gas valve, it will result in a hazardous condition.

Checking Manifold Pressures

Both Propane and Natural gas valves have a built-in pressure regulator in the gas valve. Natural gas models will have a manifold pressure of approximately 3.5" w.c. (.871 kPa) at the valve outlet with the inlet pressure to the valve from a minimum of 4.5" w.c. (1.120 kPa) for the purpose of input adjustment to a maximum of 14.0" w.c. (3.484 kPa). Propane gas models will have a manifold

pressure approximately 10.0" w.c. (2.49 kPa) at the valve outlet with the inlet pressure to the valve from a minimum of 10.8" w.c. (2.68 kPa) for the purpose of input

adjustment to a maximum of 14.0" w.c. (3.484 kPa).

Figure 7

23552-4-0408

Page 11

Image 11
Contents Installation Instructions Table of Contents Important Safety Information LP-GAS Warning Odor Safety Information for Users of LP GASKeep Clear of ALL Obstructions Requirements for MassachusettsIntroduction DVVK-4RP SpecificationsDVVK-4TSP DVVK-4TPDVD32 DVD36 DVD42 DVD48 Fireplace DimensionsDim Combustible Material Mantel Chart FigureClearances Clearance to CombustiblesLocating Fireplace Checking Manifold Pressures Installing a New Main Gas CockGAS Supply Recommended Gas Pipe DiameterConverting flue take-off to rear venting Rear Vent ConversionSpecial Vent Systems Vent Pipe Clearance InstallationFraming and Finishing Finishing Figures 13 Flush Mount Mantel Installation FigureFraming Figure VERTICAL, 90 Elbow with Horizontal Termination Flush Wall InstallationVERTICAL, 90 Elbow to Horizontal OUT the Wall Horizontal ONLY, Straight OUT the BackDim Example a Venting Graph Dimensions in FeetVenting Fireplace TOP To Use the Vent Graph FigureVenting Fireplace TOP Below Grade InstallationPositioning the Fireplace Fireplace Hard Elbow Dimensions SeriesCutting the Hole Figures Fireplace Flex Pipe 90 Degree Bend SeriesExamples TOP Vent RUN Venting Fireplace Rear Examples Rear Vent RUN Information on Various Venting Routes and Components Vertical Sidewall InstallationsTermination Clearances Vent Clearances Special Venting Components Simpson Duravent Installing Vent Components FigureVent System Identification Horizontal Firestops Figure Installing Support Brackets FigureInstalling Firestops Framing and FinishingSee Horizontal Termination Page 29 and Vertical Termination Vertical Firestops Figures 40, 41Horizontal Termination Parts Verification DVVK-4RE Vent KIT Installation InstructionsInstalling Wall Thimble/Firestop Assembly DVVK-4RE Vent KIT Installation Instructions Connecting to Rigid Vent System Parts ListDVVK-4F Flex Vent Instructions InstallationDetermining Minimum Vent Height Above the Roof General MaintenanceInstalling the Vent System in a Chase Vertical TerminationReassembly and Resealing Vent Pipe System Installation of Vertical Inlet BaffleEmber Material Placement on Burner LOG Placement 5 LOG SETLOG Placement 7 LOG SET Pilot Flame Figure Operating InstructionsMillivolt System Initial LightingTRW Standing Pilot Wiring Diagram Personal injury or loss of life Standing Pilot Lighting InstructionsGlass soots Standing Pilot TroubleshootingFrequent pilot outage problem Pilot and main burner extinguish while in operationElectric 120 volt Operated Remote Control Frec Direct Ignition Wiring DiagramOptional Remote Control What to do if YOU Smell GAS Direct Ignition Lighting InstructionsInitial Start UP GAS Line Purge Direct Ignition TroubleshootingSymptom Check Action Valve Conversion Direct Ignition PROPANE/LP GAS ConversionMaxitrol Valve Conversion Please Note Maintenance and ServiceParts List Parts View Blower Wheels FBB4 Optional Variable Speed Blower InstallationWiring Blower MotorVolt AC Optional Brick Liner Installation Instructions Junction BOX Wiring Installation InstructionsAged Brick AccessoriesAccessory Description Model Number HerringboneLeaf Arch Mission Arch Plain Arch Decorative AccessoriesMission Arch Leaf Leaf Rectangle Mission Rectangle Plain RectangleService Notes HOW to Order Repair PartsService Notes Service Notes Service Notes Comfort Systems

2, 1, DVD32FP3, 3)(N specifications

Empire Comfort Systems has long been a staple in the heating industry, offering innovative solutions for home heating needs. Among their impressive lineup, the Empire Comfort Systems 3)(N,1,2,DVD32FP3 stand-out model highlights a blend of traditional craftsmanship and modern technology. This fireplace insert is designed to provide warmth and an inviting atmosphere to any living space.

One of the primary features of the DVD32FP3 is its impressive efficiency. The unit is fueled by natural gas, which not only ensures a dependable heat source but also provides relatively lower operational costs. This model boasts a high efficiency rating, allowing homeowners to enjoy significant savings on utility bills while keeping the environment in mind. Its design allows for efficient heat distribution, ensuring that warmth fills the room without excessive energy consumption.

The Empire 3)(N,1,2,DVD32FP3 also emphasizes user convenience with its innovative controls. It features an adjustable thermostat that allows users to set their desired temperature easily, enhancing comfort levels within the home. A remote control option is also available, adding an extra layer of convenience for adjusting the fireplace settings from anywhere in the room.

Aesthetic appeal is another highlight of this model. With its sleek, contemporary design, the DVD32FP3 can blend seamlessly with various home decors. The unit is equipped with a large viewing window, providing a stunning visual of the flames while also giving a cozy ambiance to the space. The realistic log set enhances the appearance, mimicking the beauty of a traditional wood-burning fireplace without the hassle of wood maintenance.

Safety is of paramount importance with the Empire Comfort Systems 3)(N,1,2,DVD32FP3. It comes with a built-in safety sensor which ensures that the unit operates safely, providing peace of mind to homeowners. Additionally, its zero-clearance design allows for installation in various spaces without needing excessive modifications to existing structures.

Durability is a key characteristic of this fireplace insert, crafted from quality materials that promise longevity in performance. This makes it a reliable choice for home heating needs that can withstand the test of time and usage.

Overall, Empire Comfort Systems 3)(N,1,2,DVD32FP3 stands out for its combination of efficiency, aesthetic appeal, user-friendly features, and safety measures, making it an excellent choice for homeowners looking for comfort and reliability in their heating solutions. Whether you're nestled by the fire on a cold winter night or enhancing your living space, it's a perfect choice for warmth and style.