VERTICAL TERMINATION

Locate and mark the center point of the vent pipe using a nail on the underside of the roof. Drive the nail through the center point. Mark the outline of the roof hole around this center point.

NOTE: Size of the roof hole dimensions depend on the pitch of the roof. There must be a 1 inch clearance (25 mm) to the vertical pipe sections. This clearance is to all combustible material.

Cover the opening of the vent pipe and cut and frame the roof hole. Use framing lumber the same size as the roof rafters and install the frame securely. Flashing anchored to frame must withstand high winds. The storm collar is placed over this joint to make a water- tight seal. Non-hardening sealant should be used to completely seal this flashing installation.

Determining Minimum Vent Height Above the Roof.

WARNING: Major U.S. building codes specify minimum chimney and/or vent height above the roof top. These minimum heights are necessary in the interest of safety. These specifica- tions are summarized in Figure 51.

 

 

LOWEST

 

 

DISCHARGE

VENT CAP

 

OPENING

 

 

 

GAS VENT

H

ROOF PITCH IS X/12

H (Min.) - Minimum height from roof to lowest discharge opening

ROOF PITCH

H (Min.)

Flat to 6/12

12" (305 mm)

6/12 to 7/12

15" (381 mm)

Over 7/12 to 8/12

18" (457 mm)

Over 8/12 to 16/12

24" (610 mm)

Over 16/12 to 21/12

36" (914 mm)

Figure 51

Note that for steep roof pitches, the vent height must be increased. In high wind conditions, nearby trees, adjoining roof lines, steep pitched roofs, and other similar factors can result in poor draft, or down-drafting. In these cases, increasing the vent height may solve this problem.

General Maintenance

Conduct an inspection of the venting system semi-annually. Recommended areas to inspect are as follows:

1.Check areas of the venting system which are exposed to the elements for corrosion. These will appear as rust spots or streaks and, in extreme cases, holes. These components should immediately be replaced.

2.Remove the cap and shine a flashlight down the vent. Remove any bird nests or other foreign material.

3.Check for evidence of excessive condensate, such as water droplets forming in the inner liner and subsequently dripping out at joints. Condensate can cause corrosion of caps, pipe and fittings. It may be caused by having excessive lateral runs, too many elbows and exterior portions of the system being exposed to cold weather.

4.Inspect joints to verify that no pipe sections or fittings have been disturbed and, consequently, loosened. Also, check mechanical supports, such as wall straps or plumbers’ tape for rigidity.

Venting terminal shall not be recessed into a wall or siding.

Aremovable panel or other means must be provided in the enclosure for visual inspection of the flue connection.

NOTE: This also pertains to vertical vent systems installed on the outside of the building.

Slide the vertical vent cap over the ends of the vent pipe and secure. (See Figure 52)

Installing the Vent System in a Chase

A chase is a vertical box-like structure built to enclose the gas appliance and/or it’s vent system. Vertical vent runs on the outside of a building may be, but are not required to be installed inside a chase.

Figure 52

CAUTION: Treatment of firestop spacers and construction of the chase may vary with the type of building. These instructions are not substitutes for the requirements of local building codes. Therefore, your local building codes must be checked to determine the requirements for these steps.

NOTE: When installing this vent system in a chase, it is always good building practice to insulate the chase as you would the outside walls of your home. This is especially important for cold climate installations. Upon completion of building your chase framing, install the vent system by following the instructions in this manual. Remember to build the chase large enough so that minimum clearance of combustible materials (including insulation) to the vent system are maintained.

Page 34

23552-4-0408

Image 34
Contents Installation Instructions Table of Contents Important Safety Information Safety Information for Users of LP GAS LP-GAS Warning OdorRequirements for Massachusetts Keep Clear of ALL ObstructionsIntroduction DVVK-4TP SpecificationsDVVK-4TSP DVVK-4RPDim Fireplace DimensionsDVD32 DVD36 DVD42 DVD48 Clearance to Combustibles Mantel Chart FigureClearances Combustible MaterialLocating Fireplace Recommended Gas Pipe Diameter Installing a New Main Gas CockGAS Supply Checking Manifold PressuresSpecial Vent Systems Rear Vent ConversionConverting flue take-off to rear venting Framing and Finishing InstallationVent Pipe Clearance Framing Figure Flush Mount Mantel Installation FigureFinishing Figures 13 Flush Wall Installation VERTICAL, 90 Elbow with Horizontal TerminationHorizontal ONLY, Straight OUT the Back VERTICAL, 90 Elbow to Horizontal OUT the WallDim To Use the Vent Graph Figure Venting Graph Dimensions in FeetVenting Fireplace TOP Example aBelow Grade Installation Venting Fireplace TOPFireplace Flex Pipe 90 Degree Bend Series Fireplace Hard Elbow Dimensions SeriesCutting the Hole Figures Positioning the FireplaceExamples TOP Vent RUN Venting Fireplace Rear Examples Rear Vent RUN Termination Clearances Vertical Sidewall InstallationsInformation on Various Venting Routes and Components Vent Clearances Vent System Identification Installing Vent Components FigureSpecial Venting Components Simpson Duravent Framing and Finishing Installing Support Brackets FigureInstalling Firestops Horizontal Firestops FigureVertical Firestops Figures 40, 41 See Horizontal Termination Page 29 and Vertical TerminationHorizontal Termination Installing Wall Thimble/Firestop Assembly DVVK-4RE Vent KIT Installation InstructionsParts Verification DVVK-4RE Vent KIT Installation Instructions Parts List Connecting to Rigid Vent SystemInstallation DVVK-4F Flex Vent InstructionsVertical Termination General MaintenanceInstalling the Vent System in a Chase Determining Minimum Vent Height Above the RoofInstallation of Vertical Inlet Baffle Reassembly and Resealing Vent Pipe SystemLOG Placement 5 LOG SET Ember Material Placement on BurnerLOG Placement 7 LOG SET Initial Lighting Operating InstructionsMillivolt System Pilot Flame FigureTRW Standing Pilot Wiring Diagram Standing Pilot Lighting Instructions Personal injury or loss of lifePilot and main burner extinguish while in operation Standing Pilot TroubleshootingFrequent pilot outage problem Glass sootsOptional Remote Control Direct Ignition Wiring DiagramElectric 120 volt Operated Remote Control Frec Direct Ignition Lighting Instructions What to do if YOU Smell GASSymptom Check Action Direct Ignition TroubleshootingInitial Start UP GAS Line Purge Direct Ignition PROPANE/LP GAS Conversion Valve ConversionMaxitrol Valve Conversion Maintenance and Service Please NoteParts List Parts View Blower Motor FBB4 Optional Variable Speed Blower InstallationWiring Blower WheelsVolt AC Junction BOX Wiring Installation Instructions Optional Brick Liner Installation InstructionsHerringbone AccessoriesAccessory Description Model Number Aged BrickLeaf Rectangle Mission Rectangle Plain Rectangle Decorative AccessoriesMission Arch Leaf Leaf Arch Mission Arch Plain ArchHOW to Order Repair Parts Service NotesService Notes Service Notes Service Notes Comfort Systems

2, 1, DVD32FP3, 3)(N specifications

Empire Comfort Systems has long been a staple in the heating industry, offering innovative solutions for home heating needs. Among their impressive lineup, the Empire Comfort Systems 3)(N,1,2,DVD32FP3 stand-out model highlights a blend of traditional craftsmanship and modern technology. This fireplace insert is designed to provide warmth and an inviting atmosphere to any living space.

One of the primary features of the DVD32FP3 is its impressive efficiency. The unit is fueled by natural gas, which not only ensures a dependable heat source but also provides relatively lower operational costs. This model boasts a high efficiency rating, allowing homeowners to enjoy significant savings on utility bills while keeping the environment in mind. Its design allows for efficient heat distribution, ensuring that warmth fills the room without excessive energy consumption.

The Empire 3)(N,1,2,DVD32FP3 also emphasizes user convenience with its innovative controls. It features an adjustable thermostat that allows users to set their desired temperature easily, enhancing comfort levels within the home. A remote control option is also available, adding an extra layer of convenience for adjusting the fireplace settings from anywhere in the room.

Aesthetic appeal is another highlight of this model. With its sleek, contemporary design, the DVD32FP3 can blend seamlessly with various home decors. The unit is equipped with a large viewing window, providing a stunning visual of the flames while also giving a cozy ambiance to the space. The realistic log set enhances the appearance, mimicking the beauty of a traditional wood-burning fireplace without the hassle of wood maintenance.

Safety is of paramount importance with the Empire Comfort Systems 3)(N,1,2,DVD32FP3. It comes with a built-in safety sensor which ensures that the unit operates safely, providing peace of mind to homeowners. Additionally, its zero-clearance design allows for installation in various spaces without needing excessive modifications to existing structures.

Durability is a key characteristic of this fireplace insert, crafted from quality materials that promise longevity in performance. This makes it a reliable choice for home heating needs that can withstand the test of time and usage.

Overall, Empire Comfort Systems 3)(N,1,2,DVD32FP3 stands out for its combination of efficiency, aesthetic appeal, user-friendly features, and safety measures, making it an excellent choice for homeowners looking for comfort and reliability in their heating solutions. Whether you're nestled by the fire on a cold winter night or enhancing your living space, it's a perfect choice for warmth and style.