Empire Comfort Systems DVD32FP3, 3)(N Vertical Firestops Figures 40, 41

Page 28

FRAMING AND FINISHING (continued)

Vertical Firestops (Figures 40, 41 and 42)

Vertical runs of this system which pass through ceilings require the use of ONE (1) ceiling firestop at the hole in each ceiling through which the vent passes.

Position a plumb bob directly over the center of the vertical vent component and mark the ceiling to establish the center point of the vent. Drill a hole or drive a nail through this center point and check the floor above for any obstructions such as wiring or plumbing runs. Reposition the appliance and vent system, if necessary, to accommodate ceiling joists and/or obstructions.

Cut a 10 inch x 10 inch hole through the ceiling, using the center point previously marked. Frame the hole with framing lumber the same size as the ceiling joists. (See Figure 40) If the area above the ceiling is NOT an attic, position and secure the ceiling firestop on the ceiling side of the previously cut and framed hole. (See Figure

41)If the area above the ceiling is an attic, position and secure the firestop on top of the previously framed hole. (See Figure 42)

NOTE: Remove insulation from the framed area in the attic before installing the firestop and/or vent pipes.

Figure 42

See Horizontal Termination Page 29 and Vertical Termination

Pages 34-35.

Figure 40

Figure 41

Page 28

23552-4-0408

Image 28
Contents Installation Instructions Table of Contents Important Safety Information Safety Information for Users of LP GAS LP-GAS Warning OdorRequirements for Massachusetts Keep Clear of ALL ObstructionsIntroduction Specifications DVVK-4TSPDVVK-4TP DVVK-4RPDim Fireplace DimensionsDVD32 DVD36 DVD42 DVD48 Mantel Chart Figure ClearancesClearance to Combustibles Combustible MaterialLocating Fireplace Installing a New Main Gas Cock GAS SupplyRecommended Gas Pipe Diameter Checking Manifold PressuresSpecial Vent Systems Rear Vent ConversionConverting flue take-off to rear venting Framing and Finishing InstallationVent Pipe Clearance Framing Figure Flush Mount Mantel Installation FigureFinishing Figures 13 Flush Wall Installation VERTICAL, 90 Elbow with Horizontal TerminationHorizontal ONLY, Straight OUT the Back VERTICAL, 90 Elbow to Horizontal OUT the WallDim Venting Graph Dimensions in Feet Venting Fireplace TOPTo Use the Vent Graph Figure Example aBelow Grade Installation Venting Fireplace TOPFireplace Hard Elbow Dimensions Series Cutting the Hole FiguresFireplace Flex Pipe 90 Degree Bend Series Positioning the FireplaceExamples TOP Vent RUN Venting Fireplace Rear Examples Rear Vent RUN Termination Clearances Vertical Sidewall InstallationsInformation on Various Venting Routes and Components Vent Clearances Vent System Identification Installing Vent Components FigureSpecial Venting Components Simpson Duravent Installing Support Brackets Figure Installing FirestopsFraming and Finishing Horizontal Firestops FigureVertical Firestops Figures 40, 41 See Horizontal Termination Page 29 and Vertical TerminationHorizontal Termination Installing Wall Thimble/Firestop Assembly DVVK-4RE Vent KIT Installation InstructionsParts Verification DVVK-4RE Vent KIT Installation Instructions Parts List Connecting to Rigid Vent SystemInstallation DVVK-4F Flex Vent InstructionsGeneral Maintenance Installing the Vent System in a ChaseVertical Termination Determining Minimum Vent Height Above the RoofInstallation of Vertical Inlet Baffle Reassembly and Resealing Vent Pipe SystemLOG Placement 5 LOG SET Ember Material Placement on BurnerLOG Placement 7 LOG SET Operating Instructions Millivolt SystemInitial Lighting Pilot Flame FigureTRW Standing Pilot Wiring Diagram Standing Pilot Lighting Instructions Personal injury or loss of lifeStanding Pilot Troubleshooting Frequent pilot outage problemPilot and main burner extinguish while in operation Glass sootsOptional Remote Control Direct Ignition Wiring DiagramElectric 120 volt Operated Remote Control Frec Direct Ignition Lighting Instructions What to do if YOU Smell GASSymptom Check Action Direct Ignition TroubleshootingInitial Start UP GAS Line Purge Direct Ignition PROPANE/LP GAS Conversion Valve ConversionMaxitrol Valve Conversion Maintenance and Service Please NoteParts List Parts View FBB4 Optional Variable Speed Blower Installation WiringBlower Motor Blower WheelsVolt AC Junction BOX Wiring Installation Instructions Optional Brick Liner Installation InstructionsAccessories Accessory Description Model NumberHerringbone Aged BrickDecorative Accessories Mission Arch LeafLeaf Rectangle Mission Rectangle Plain Rectangle Leaf Arch Mission Arch Plain ArchHOW to Order Repair Parts Service NotesService Notes Service Notes Service Notes Comfort Systems

2, 1, DVD32FP3, 3)(N specifications

Empire Comfort Systems has long been a staple in the heating industry, offering innovative solutions for home heating needs. Among their impressive lineup, the Empire Comfort Systems 3)(N,1,2,DVD32FP3 stand-out model highlights a blend of traditional craftsmanship and modern technology. This fireplace insert is designed to provide warmth and an inviting atmosphere to any living space.

One of the primary features of the DVD32FP3 is its impressive efficiency. The unit is fueled by natural gas, which not only ensures a dependable heat source but also provides relatively lower operational costs. This model boasts a high efficiency rating, allowing homeowners to enjoy significant savings on utility bills while keeping the environment in mind. Its design allows for efficient heat distribution, ensuring that warmth fills the room without excessive energy consumption.

The Empire 3)(N,1,2,DVD32FP3 also emphasizes user convenience with its innovative controls. It features an adjustable thermostat that allows users to set their desired temperature easily, enhancing comfort levels within the home. A remote control option is also available, adding an extra layer of convenience for adjusting the fireplace settings from anywhere in the room.

Aesthetic appeal is another highlight of this model. With its sleek, contemporary design, the DVD32FP3 can blend seamlessly with various home decors. The unit is equipped with a large viewing window, providing a stunning visual of the flames while also giving a cozy ambiance to the space. The realistic log set enhances the appearance, mimicking the beauty of a traditional wood-burning fireplace without the hassle of wood maintenance.

Safety is of paramount importance with the Empire Comfort Systems 3)(N,1,2,DVD32FP3. It comes with a built-in safety sensor which ensures that the unit operates safely, providing peace of mind to homeowners. Additionally, its zero-clearance design allows for installation in various spaces without needing excessive modifications to existing structures.

Durability is a key characteristic of this fireplace insert, crafted from quality materials that promise longevity in performance. This makes it a reliable choice for home heating needs that can withstand the test of time and usage.

Overall, Empire Comfort Systems 3)(N,1,2,DVD32FP3 stands out for its combination of efficiency, aesthetic appeal, user-friendly features, and safety measures, making it an excellent choice for homeowners looking for comfort and reliability in their heating solutions. Whether you're nestled by the fire on a cold winter night or enhancing your living space, it's a perfect choice for warmth and style.