Empire Comfort Systems DVD32FP3, 1, 3)(N installation instructions Introduction

Page 6

INTRODUCTION

Instructions to Installer

1.Installer must leave instruction manual with owner after installation.

2.Installer must have owner fill out and mail warranty card supplied with the fireplace.

3.Installer should show owner how to start and operate the fireplace.

This direct vent gas fireplace heater is designed to operate with all combustion air being siphoned from the outside of the building and all exhaust gases expelled to the outside of the building. The information contained in this manual pertains to all models and gas control systems unless otherwise noted.

Warning: This unit is not for use with solid fuels.

Appliance Certification

This fireplace is design certified in accordance with American National Standard/CSA Standard ANSI Z.21-88/CSA 2.33 and by Underwriters Laboratories as a Direct Vent Gas Fireplace Heater and shall be installed according to these instructions.

Consult your local building code agency, prior to installation, to ensure compliance with local codes-including permits and inspections.

The fireplace, when installed, must be electrically grounded in accordance with local codes or, in absence of local codes, with the National Electric Code ANSI/NFPA 70 or Canadian Electric code, CSA C22.1, if an external electrical source is utilized.

These models may be installed in a bedroom or bed-sitting room in the U.S.A. and Canada.

Qualified Installing Agency

Installation and replacement of gas piping, gas utilization equipment or accessories and repair and servicing of equipment shall be performed only by a qualified agency. The term “qualified agency” means any individual, firm, corporation or company which either in person or through a representative is engaged in and is responsible for (a) the installation or replacement of gas piping or (b) the connection, installation, repair or servicing of equipment, who is experienced in such work, familiar with all precautions required and has complied with all the requirements of the authority having jurisdiction.

State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts.

The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code ANSI Z223.1/NFPA 54* Natural Gas and Propane Installation Code, or CSA B149.1

in Canada.*Available from the American National Standards Institute, Inc. 11 West 42nd St., New York, N.Y. 10036.

Warning: ANY CHANGE TO THIS FIREPLACE OR ITS CONTROLS CAN BE DANGEROUS.

Improper installation or use of the fireplace can cause serious injury or death from fire, burns, explosions, or carbon monoxide poisoning.

Any alteration of the original design, installed other than as shown in these instructions oruse with a type of gas not shown on the rating plate is the responsibility of the person and company making the change.

Important

All correspondence should refer to complete Model Number, Serial Number and type of gas.

High Altitude

When installing this unit at an elevation above 2000 feet (in the United States) it may be necessary to decrease the input rating by changing the existing burner orifice to a smaller size. Generally, input should be reduced 4 percent for each 1000 feet above sea level. However, if the heating value of the gas has been reduced, this general rule may not apply. Check with local gas utility for proper orifice size identification.

Canadian High Altitude Altitude: 0-4500 feet (0-1370 m)

When installing this unit at an elevation above 4500 feet (in Canada), check with local authorities.

Consult your local gas utility for assistance in determining the proper orifice for location.

Preparation

This direct vent gas fireplace and its components are tested and safe when installed in accordance with this Installation Manual. Report to your dealer any parts damaged in shipment, specifically check glass condition. Do not install unit with damaged, incomplete, or substitute parts. Read all instructions before starting installation and follow these instructions carefully during installation to insure maximum benefit and safety. Failure to follow them will void your warranty and may present a fire hazard.

The warranty will be voided by, and the warranter disclaims any responsibility for the following actions:

Installation of any damaged fireplace or vent system component.

Modification of the fireplace or direct vent system.

Installation other than as instructed by Empire Comfort Systems, Inc.

Improper positioning of the logs, glass door or decorative rock.

Installation and/or use of any component part not manufactured or approved by manufacturer.

Page 6

23552-4-0408

Image 6
Contents Installation Instructions Table of Contents Important Safety Information Safety Information for Users of LP GAS LP-GAS Warning OdorRequirements for Massachusetts Keep Clear of ALL ObstructionsIntroduction DVVK-4TP SpecificationsDVVK-4TSP DVVK-4RPFireplace Dimensions DimDVD32 DVD36 DVD42 DVD48 Clearance to Combustibles Mantel Chart FigureClearances Combustible MaterialLocating Fireplace Recommended Gas Pipe Diameter Installing a New Main Gas CockGAS Supply Checking Manifold PressuresRear Vent Conversion Special Vent SystemsConverting flue take-off to rear venting Installation Framing and FinishingVent Pipe Clearance Flush Mount Mantel Installation Figure Framing FigureFinishing Figures 13 Flush Wall Installation VERTICAL, 90 Elbow with Horizontal TerminationHorizontal ONLY, Straight OUT the Back VERTICAL, 90 Elbow to Horizontal OUT the WallDim To Use the Vent Graph Figure Venting Graph Dimensions in FeetVenting Fireplace TOP Example aBelow Grade Installation Venting Fireplace TOPFireplace Flex Pipe 90 Degree Bend Series Fireplace Hard Elbow Dimensions SeriesCutting the Hole Figures Positioning the FireplaceExamples TOP Vent RUN Venting Fireplace Rear Examples Rear Vent RUN Vertical Sidewall Installations Termination ClearancesInformation on Various Venting Routes and Components Vent Clearances Installing Vent Components Figure Vent System IdentificationSpecial Venting Components Simpson Duravent Framing and Finishing Installing Support Brackets FigureInstalling Firestops Horizontal Firestops FigureVertical Firestops Figures 40, 41 See Horizontal Termination Page 29 and Vertical TerminationHorizontal Termination DVVK-4RE Vent KIT Installation Instructions Installing Wall Thimble/Firestop AssemblyParts Verification DVVK-4RE Vent KIT Installation Instructions Parts List Connecting to Rigid Vent SystemInstallation DVVK-4F Flex Vent InstructionsVertical Termination General MaintenanceInstalling the Vent System in a Chase Determining Minimum Vent Height Above the RoofInstallation of Vertical Inlet Baffle Reassembly and Resealing Vent Pipe SystemLOG Placement 5 LOG SET Ember Material Placement on BurnerLOG Placement 7 LOG SET Initial Lighting Operating InstructionsMillivolt System Pilot Flame FigureTRW Standing Pilot Wiring Diagram Standing Pilot Lighting Instructions Personal injury or loss of lifePilot and main burner extinguish while in operation Standing Pilot TroubleshootingFrequent pilot outage problem Glass sootsDirect Ignition Wiring Diagram Optional Remote ControlElectric 120 volt Operated Remote Control Frec Direct Ignition Lighting Instructions What to do if YOU Smell GASDirect Ignition Troubleshooting Symptom Check ActionInitial Start UP GAS Line Purge Direct Ignition PROPANE/LP GAS Conversion Valve ConversionMaxitrol Valve Conversion Maintenance and Service Please NoteParts List Parts View Blower Motor FBB4 Optional Variable Speed Blower InstallationWiring Blower WheelsVolt AC Junction BOX Wiring Installation Instructions Optional Brick Liner Installation InstructionsHerringbone AccessoriesAccessory Description Model Number Aged BrickLeaf Rectangle Mission Rectangle Plain Rectangle Decorative AccessoriesMission Arch Leaf Leaf Arch Mission Arch Plain ArchHOW to Order Repair Parts Service NotesService Notes Service Notes Service Notes Comfort Systems

2, 1, DVD32FP3, 3)(N specifications

Empire Comfort Systems has long been a staple in the heating industry, offering innovative solutions for home heating needs. Among their impressive lineup, the Empire Comfort Systems 3)(N,1,2,DVD32FP3 stand-out model highlights a blend of traditional craftsmanship and modern technology. This fireplace insert is designed to provide warmth and an inviting atmosphere to any living space.

One of the primary features of the DVD32FP3 is its impressive efficiency. The unit is fueled by natural gas, which not only ensures a dependable heat source but also provides relatively lower operational costs. This model boasts a high efficiency rating, allowing homeowners to enjoy significant savings on utility bills while keeping the environment in mind. Its design allows for efficient heat distribution, ensuring that warmth fills the room without excessive energy consumption.

The Empire 3)(N,1,2,DVD32FP3 also emphasizes user convenience with its innovative controls. It features an adjustable thermostat that allows users to set their desired temperature easily, enhancing comfort levels within the home. A remote control option is also available, adding an extra layer of convenience for adjusting the fireplace settings from anywhere in the room.

Aesthetic appeal is another highlight of this model. With its sleek, contemporary design, the DVD32FP3 can blend seamlessly with various home decors. The unit is equipped with a large viewing window, providing a stunning visual of the flames while also giving a cozy ambiance to the space. The realistic log set enhances the appearance, mimicking the beauty of a traditional wood-burning fireplace without the hassle of wood maintenance.

Safety is of paramount importance with the Empire Comfort Systems 3)(N,1,2,DVD32FP3. It comes with a built-in safety sensor which ensures that the unit operates safely, providing peace of mind to homeowners. Additionally, its zero-clearance design allows for installation in various spaces without needing excessive modifications to existing structures.

Durability is a key characteristic of this fireplace insert, crafted from quality materials that promise longevity in performance. This makes it a reliable choice for home heating needs that can withstand the test of time and usage.

Overall, Empire Comfort Systems 3)(N,1,2,DVD32FP3 stands out for its combination of efficiency, aesthetic appeal, user-friendly features, and safety measures, making it an excellent choice for homeowners looking for comfort and reliability in their heating solutions. Whether you're nestled by the fire on a cold winter night or enhancing your living space, it's a perfect choice for warmth and style.