Empire Comfort Systems DVD32FP3, 1 Standing Pilot Troubleshooting, Frequent pilot outage problem

Page 42

STANDING PILOT TROUBLESHOOTING

With proper installation and maintenance, your new Direct Vent Gas Fireplace will provide years of trouble-free service. If you do experience a problem, refer to the Trouble Shooting Guide below. This guide will assist a qualified service person in the diagnosis

of problems and the corrective action to be taken.

1.Spark ignitor will not light pilot after repeated triggering of piezo ignitor button.

a.Defective ignitor (no spark electrode)

—Check for spark at electrode and pilot; if no spark and electrode wire is properly connected, replace ignitor.

b.No gas or low gas pressure.

—Check remote shut off valves from fireplace. Usually there is a valve near the main. There can be more than one

(1) valve between the fireplace and main.

—Low pressure can be caused by a variety of situations such as a bent line, too narrow diameter of pipe, or low line pressure. Consult with plumber or gas supplier.

c.No LP in tank.

—Check LP (propane) tank. Refill tank.

2.Pilot will not stay lit after carefully following lighting instructions.

a.Defective thermocouple.

—Check that pilot flame impinges on thermocouple. Clean and/or adjust pilot for maximum flame impingement. —Ensure the thermocouple connection at the gas valve is fully inserted and tight (hand tight plus 1/4 turn). Faulty thermocouple if reading is below specified minimum of 15 millivolts.

—Disconnect the thermocouple from the valve, place one millivolt meter lead wire on the end of the thermocouple and the other millivolt meter lead wire on the thermocouple copper wire. Start the pilot and hold the valve knob in. If the millivolt reading is less than 15 millivolt, replace the thermocouple.

b.Defective valve.

—If thermocouple is producing more than 15 millivolts, replace faulty valve.

3.Pilot burning, no gas to burner, valve knob “ON”, REMOTE/ OFF/ON switch “ON.”

a.REMOTE/OFF/ON switch, wall switch, remote control or wires defective.

—Check REMOTE/OFF/ON switch and wires for proper connections. Place jumper wires across terminal at switch. If burner comes on, replace defective switch. If OK, place jumper wires across switch wires at gas valve-if burner comes on, wires are faulty or connections are bad.

b.Thermopile may not be generating sufficient millivolts. —If the pilot flame is not close enough physically to the thermopile, adjust the pilot flame.

—Be sure the wire connections from the thermopile at the gas valve terminals are tight and the thermopile is fully inserted into the pilot bracket.

—Check the thermopile with a millivolt meter. Take the reading at TH-TP & TP terminals of the gas valve. The meter should read 350 millivolts minimum, while holding the valve knob depressed in the PILOT position, with the pilot lit, and the REMOTE/OFF/ON switch in the OFF position. Replace the faulty thermopile if the reading is below the specified minimum.

—With the pilot in the ON position, disconnect the thermopile leads from the valve. Take a reading at the thermopile leads. The reading should be 350 millivolts minimum. Replace the thermopile if the reading is below the minimum.

c.Defective valve.

—Turn valve knob to ON. Place REMOTE/OFF/ON switch to ON. Check with millivolt meter at thermopile terminals. Millivolt meter should read greater than 200 millivolts. If the reading is okay and the main burner does not ignite, replace the gas valve.

d.Plugged main burner orifice.

—Check main burner orifice for blockage and remove.

4.Frequent pilot outage problem.

a.Pilot flame may be too high or too low, or blowing (high), causing pilot safety to drop out.

—Cleanandadjustflameformaximumflameimpingementon the thermocouple. Follow lighting instructions carefully.

5.The pilot and main burner extinguish while in operation.

a.No LP (Propane) in tank.

Check LP (Propane) tank. Refill fuel tank.

b.Inner vent pipe leaking exhaust gases back into system —Check for leaks.

c.Glass too loose, gasket leaks in corners after usage. —Be certain glass assembly is installed correctly.

d.Horizontal vent improperly pitched.

—The horizontal vent cap should slope down only enough to prevent any water from entering the unit. The maximum downwards slope is 1/4 inch.

e.Bad thermopile or thermocouple. —Replace if necessary.

f.Improper vent cap installation.

—Check for proper installation and freedom from debris or blockage.

6.Glass soots.

a.Flame impingement on logs.

—Check and adjust log position. Contact Empire Comfort Systems, Inc.

b.Debris around throat of main burner.

—Inspect the opening at the base of the main burner. It is imperative that NO material be placed in this opening.

7.Flame burns blue and lifts off main burner.

a.Insufficient oxygen being supplied.

—Check to make sure vent cap is installed properly and free of debris. Make sure that vent system joints are tight and have no leaks.

—Check to make sure that no material has been placed at the main burner base.

Page 42

23552-4-0408

Image 42
Contents Installation Instructions Table of Contents Important Safety Information Safety Information for Users of LP GAS LP-GAS Warning OdorRequirements for Massachusetts Keep Clear of ALL ObstructionsIntroduction DVVK-4TP SpecificationsDVVK-4TSP DVVK-4RPFireplace Dimensions DimDVD32 DVD36 DVD42 DVD48 Clearance to Combustibles Mantel Chart FigureClearances Combustible MaterialLocating Fireplace Recommended Gas Pipe Diameter Installing a New Main Gas CockGAS Supply Checking Manifold PressuresRear Vent Conversion Special Vent SystemsConverting flue take-off to rear venting Installation Framing and FinishingVent Pipe Clearance Flush Mount Mantel Installation Figure Framing FigureFinishing Figures 13 Flush Wall Installation VERTICAL, 90 Elbow with Horizontal TerminationHorizontal ONLY, Straight OUT the Back VERTICAL, 90 Elbow to Horizontal OUT the WallDim To Use the Vent Graph Figure Venting Graph Dimensions in FeetVenting Fireplace TOP Example aBelow Grade Installation Venting Fireplace TOPFireplace Flex Pipe 90 Degree Bend Series Fireplace Hard Elbow Dimensions SeriesCutting the Hole Figures Positioning the FireplaceExamples TOP Vent RUN Venting Fireplace Rear Examples Rear Vent RUN Vertical Sidewall Installations Termination ClearancesInformation on Various Venting Routes and Components Vent Clearances Installing Vent Components Figure Vent System IdentificationSpecial Venting Components Simpson Duravent Framing and Finishing Installing Support Brackets FigureInstalling Firestops Horizontal Firestops FigureVertical Firestops Figures 40, 41 See Horizontal Termination Page 29 and Vertical TerminationHorizontal Termination DVVK-4RE Vent KIT Installation Instructions Installing Wall Thimble/Firestop AssemblyParts Verification DVVK-4RE Vent KIT Installation Instructions Parts List Connecting to Rigid Vent SystemInstallation DVVK-4F Flex Vent InstructionsVertical Termination General MaintenanceInstalling the Vent System in a Chase Determining Minimum Vent Height Above the RoofInstallation of Vertical Inlet Baffle Reassembly and Resealing Vent Pipe SystemLOG Placement 5 LOG SET Ember Material Placement on BurnerLOG Placement 7 LOG SET Initial Lighting Operating InstructionsMillivolt System Pilot Flame FigureTRW Standing Pilot Wiring Diagram Standing Pilot Lighting Instructions Personal injury or loss of lifePilot and main burner extinguish while in operation Standing Pilot TroubleshootingFrequent pilot outage problem Glass sootsDirect Ignition Wiring Diagram Optional Remote ControlElectric 120 volt Operated Remote Control Frec Direct Ignition Lighting Instructions What to do if YOU Smell GASDirect Ignition Troubleshooting Symptom Check ActionInitial Start UP GAS Line Purge Direct Ignition PROPANE/LP GAS Conversion Valve ConversionMaxitrol Valve Conversion Maintenance and Service Please NoteParts List Parts View Blower Motor FBB4 Optional Variable Speed Blower InstallationWiring Blower WheelsVolt AC Junction BOX Wiring Installation Instructions Optional Brick Liner Installation InstructionsHerringbone AccessoriesAccessory Description Model Number Aged BrickLeaf Rectangle Mission Rectangle Plain Rectangle Decorative AccessoriesMission Arch Leaf Leaf Arch Mission Arch Plain ArchHOW to Order Repair Parts Service NotesService Notes Service Notes Service Notes Comfort Systems

2, 1, DVD32FP3, 3)(N specifications

Empire Comfort Systems has long been a staple in the heating industry, offering innovative solutions for home heating needs. Among their impressive lineup, the Empire Comfort Systems 3)(N,1,2,DVD32FP3 stand-out model highlights a blend of traditional craftsmanship and modern technology. This fireplace insert is designed to provide warmth and an inviting atmosphere to any living space.

One of the primary features of the DVD32FP3 is its impressive efficiency. The unit is fueled by natural gas, which not only ensures a dependable heat source but also provides relatively lower operational costs. This model boasts a high efficiency rating, allowing homeowners to enjoy significant savings on utility bills while keeping the environment in mind. Its design allows for efficient heat distribution, ensuring that warmth fills the room without excessive energy consumption.

The Empire 3)(N,1,2,DVD32FP3 also emphasizes user convenience with its innovative controls. It features an adjustable thermostat that allows users to set their desired temperature easily, enhancing comfort levels within the home. A remote control option is also available, adding an extra layer of convenience for adjusting the fireplace settings from anywhere in the room.

Aesthetic appeal is another highlight of this model. With its sleek, contemporary design, the DVD32FP3 can blend seamlessly with various home decors. The unit is equipped with a large viewing window, providing a stunning visual of the flames while also giving a cozy ambiance to the space. The realistic log set enhances the appearance, mimicking the beauty of a traditional wood-burning fireplace without the hassle of wood maintenance.

Safety is of paramount importance with the Empire Comfort Systems 3)(N,1,2,DVD32FP3. It comes with a built-in safety sensor which ensures that the unit operates safely, providing peace of mind to homeowners. Additionally, its zero-clearance design allows for installation in various spaces without needing excessive modifications to existing structures.

Durability is a key characteristic of this fireplace insert, crafted from quality materials that promise longevity in performance. This makes it a reliable choice for home heating needs that can withstand the test of time and usage.

Overall, Empire Comfort Systems 3)(N,1,2,DVD32FP3 stands out for its combination of efficiency, aesthetic appeal, user-friendly features, and safety measures, making it an excellent choice for homeowners looking for comfort and reliability in their heating solutions. Whether you're nestled by the fire on a cold winter night or enhancing your living space, it's a perfect choice for warmth and style.