Goodman Mfg VC8 instruction manual Propane Gas Installation Typ

Page 21

CIRCULATING AIR AND FILTERS

PROPANE GAS TANKS AND PIPING

WARNING

IF THE GAS FURNACE IS INSTALLED IN A BASEMENT, AN EXCAVATED AREA OR CONFINED SPACE, IT IS STRONGLY RECOMMENDED TO CONTACT A PROPANE SUPPLIER TO INSTALL A GAS DETECTING WARNING DEVICE IN CASE OF A GAS LEAK.

SINCE PROPANE GAS IS HEAVIER THAN AIR, ANY LEAKING GAS CAN SETTLE IN ANY LOW AREAS OR CONFINED SPACES.

PROPANE GAS ODORANT MAY FADE, MAKING THE GAS UNDETECTABLE EXCEPT WITH A WARNING DEVICE.

A gas detecting warning system is the only reliable way to detect a propane gas leak. Rust can reduce the level of odorant in propane gas. Do not rely on your sense of smell. Contact a local propane gas supplier about installing a gas detecting warning system. If the presence of gas is suspected, follow the instructions on Page 3 of this manual.

All propane gas equipment must conform to the safety stan- dards of the National Board of Fire Underwriters, NBFU Manual 58.

For satisfactory operation, propane gas pressure must be 10 inch WC at the furnace manifold with all gas appliances in operation. Maintaining proper gas pressure depends on three main factors:

1.Vaporization rate, depending on temperature of the liquid, and “wetted surface” area of the container or containers.

2.Proper pressure regulation. (Two-stage regulation is recommended for both cost and efficiency).

3.Pressure drop in lines between regulators, and between second stage regulator and the appliance. Pipe size will depend on length of pipe run and total load of all appliances.

Complete information regarding tank sizing for vaporization, rec- ommended regulator settings, and pipe sizing is available from most regulator manufacturers and propane gas suppliers.

Since propane gas will quickly dissolve white lead and most standard commercial compounds, special pipe dope must be used. Shellac-based compounds resistant to the actions of liquefied petroleum gases such as Gasolac®, Stalactic®, Clyde’s® or John Crane® are satisfactory.

Refer to the following illustration for typical propane gas instal- lations and piping.

First Stage

5 to 15 PSIG

 

(20 PSIG Max.)

 

Regulator

Continuous

 

 

11" W.C.

200 PSIG

 

Second Stage

Maximum

 

Regulator

Propane Gas Installation (Typ.)

PROPANE GAS PIPING CHARTS

Sizing Between First and Second Stage Regulator*

Maximum Propane Capacities listed are based on 2 psig pressure drop at 10 psig setting. Capacities in 1,000 BTU/hour.

 

Pipe or

 

 

 

 

Tubing Size, O.D. Type L

 

 

 

 

 

Nominal Pipe Size

 

Tubing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Schedule 40

 

Length,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3/8"

 

 

1/2"

 

5/8"

 

 

3/4"

 

 

7/8"

1/2"

 

 

3/4"

 

Feet

 

 

 

 

 

 

 

 

 

 

10

 

730

 

 

1,700

 

3,200

 

5,300

 

8,300

3,200

 

7,500

 

20

 

500

 

 

1,100

 

2,200

 

3,700

 

5,800

2,200

 

4,200

 

30

 

400

 

 

920

 

2,000

 

2,900

 

4,700

1,800

 

4,000

 

40

 

370

 

 

850

 

1,700

 

2,700

 

4,100

1,600

 

3,700

 

50

 

330

 

 

770

 

1,500

 

2,400

 

3,700

1,500

 

3,400

 

60

 

300

 

 

700

 

1,300

 

2,200

 

3,300

1,300

 

 

310

 

80

 

260

 

 

610

 

1,200

 

1,900

 

2,900

1,200

 

2,600

 

100

 

220

 

 

540

 

1,000

 

1,700

 

2,600

1,000

 

2,300

 

125

 

200

 

 

490

 

900

 

 

1,400

 

2,300

900

 

2,100

 

150

 

190

 

 

430

 

830

 

 

1,300

 

2,100

830

 

1,900

 

175

 

170

 

 

400

 

780

 

 

1,200

 

1,900

770

 

1,700

 

200

 

160

 

 

380

 

730

 

 

1,100

 

1,800

720

 

1,500

 

Sizing Between Second Stage and Appliance Regulator*

 

 

 

 

 

 

 

 

 

 

 

 

Maximum Propane Capacities listed are based on 2 psig pressure drop at 10 psig setting.

 

 

 

 

 

Capacities in 1,000 BTU/hour.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pipe or

 

 

 

Tubing Size, O.D. Type L

 

 

 

 

Nominal Pipe Size

 

 

 

Tubing

 

 

 

 

 

 

 

Schedule 40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Length,

 

3/8"

 

1/2"

5/8"

 

3/4"

 

7/8"

 

1-1/8"

1/2"

 

3/4"

 

1"

1-1/4"

 

1-1/2"

 

Feet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

39

 

92

199

 

329

 

501

 

935

275

 

567

 

1,071

2,205

 

3,307

 

20

 

26

 

62

131

 

216

 

346

 

630

189

 

393

 

732

1,496

 

2,299

 

30

 

21

 

50

107

 

181

 

277

 

500

152

 

315

 

590

1,212

 

1,858

 

40

 

19

 

41

90

 

145

 

233

 

427

129

 

267

 

504

1,039

 

1,559

 

50

 

18

 

37

79

 

131

 

198

 

376

114

 

237

 

448

91

 

1,417

 

60

 

16

 

35

72

 

121

 

187

 

340

103

 

217

 

409

834

 

1,275

 

80

 

13

 

29

62

 

104

 

155

 

289

89

 

185

 

346

724

 

1,066

 

100

 

11

 

26

55

 

90

 

138

 

255

78

 

162

 

307

630

 

976

 

125

 

10

 

24

48

 

81

 

122

 

224

69

 

146

 

275

567

 

866

 

150

 

9

 

21

43

 

72

 

109

 

202

63

 

132

 

252

511

 

787

 

200

 

8

 

19

39

 

66

 

100

 

187

54

 

112

 

209

439

 

665

 

250

 

8

 

17

36

 

60

 

93

 

172

48

 

100

 

185

390

 

590

CIRCULATING AIR AND FILTERS

WARNING

NEVER ALLOW THE PRODUCTS OF COMBUSTION, INCLUDING CARBON MONOXIDE, TO ENTER THE RETURN DUCT WORK OR CIRCULATION AIR SUPPLY.

Duct systems and register sizes must be properly designed for the CFM and external static pressure rating of the furnace. Ductwork should be designed in accordance with the recom- mended methods of “Air Conditioning Contractors of America” Manual D.

A duct system must be installed in accordance with Standards of the National Board of Fire Underwriters for the Installation of Air Conditioning, Warm Air Heating and Ventilating Systems. Pamphlets No. 90A and 90B.

21

Image 21
Contents Installation Instructions for *D, MVC8 GAS Furnace Upright Installations Table of Contents What to do if YOU Smell GAS Safety PrecautionsKeep this literature in a safe place for future reference Product ApplicationProduct Description Location Requirements and ConsiderationsNational Fire Protection Association, Inc CSA InternationalClearances and Accessibility Combustion & Ventilation Category Following vent testing procedure is reproduced fromCategory I Venting Vertical Venting Exterior Masonry Chimneys Category I Furnaces onlyExteriormasonrychimneyscategoryifurnacesonly Proper Chimney Termination? Check Check 3 Chimney Crown Condition Electrical Connections High Voltage Important Note Single Stage Heating with Single Stage Cooling Thermostat Wiring DiagramsGAS Supply and Piping Accessories WiringGas Altitude Kit Orifice Manifold Pressure Circulating AIR and FiltersGeneral Furnace Layout Propane Gas Installation Typ Checking Static Pressure 80% Furnace Shown, 90% Similar START-UP Procedure and AdjustmentUpright Installations Honeywell Model VR9205 Connected to Manometer White-Rodgers Model 36G54 Two-StageWhite-Rodgers Model 36G54 Connected to Manometer Honeywell Model VR9205 Two-StageMeasuring Inlet Gas Pressure Alt. Method Example Temperature Rise MeasurementSwitch Bank S4 Heat Off Delay Dipswitches Switch Bank S4Comfortnet System Comfortnet SystemCTK01AA System Wiring using Four-WiresTo step to the next item Configuration Cool Airflow CL CFM Normal Sequence of Operation Operational Checks & Safety Circuit DescriptionOperational Checks Troubleshooting & Maintenance Safety Circuit DescriptionTroubleshooting Miscellaneous MaintenanceRepair and Replacement Parts Before Leaving AN InstallationInternal Troubleshooting ChartLimit Message ChartInvalid Trips Status Codes AIR Flow Data DIP SwitchesRD WH MVC8AA Wiring DiagramMVC8AB, *DVC8AA Wiring Diagram

VC8 specifications

Goodman Manufacturing has established itself as a leading provider of quality heating, ventilation, and air conditioning (HVAC) systems. Among its impressive lineup is the Goodman VC8, a versatile and efficient variable-capacity air conditioner that stands out due to its innovative design and advanced technologies.

The Goodman VC8 is known for its superior energy efficiency, featuring a SEER (Seasonal Energy Efficiency Ratio) rating higher than 20. This means that it operates efficiently across various climatic conditions, ensuring optimal cooling with minimal energy consumption. The high SEER rating not only translates to lower energy bills but also contributes to a reduced environmental footprint, making it a smart choice for eco-conscious consumers.

One of the standout features of the VC8 is its variable-speed compressor, which allows the system to adjust its output based on the cooling needs of the space. This technology enables the unit to run at lower speeds for longer periods, maintaining a consistent temperature while reducing energy usage. The variable-speed operation also contributes to quieter operation compared to traditional air conditioning systems. Homeowners can enjoy a peaceful indoor environment without the disruptive noise commonly associated with air conditioning units.

In terms of comfort, the Goodman VC8 employs advanced humidity control features, ensuring that moisture is efficiently managed within the space. This not only enhances comfort levels but also helps to prevent issues related to excessive humidity, such as mold growth and structural damage.

The VC8 is designed for reliable performance and durability, with its robust construction and dependable components. Goodman manufactures its products with high-quality materials to withstand the rigors of daily use and various weather conditions, ensuring long-lasting operation.

Additionally, the VC8 incorporates smart technology features, including compatibility with Wi-Fi-enabled thermostats. Homeowners can easily monitor and control their system remotely, providing convenience and peace of mind.

The Goodman VC8 is an exemplary solution for those looking for an energy-efficient, advanced air conditioning system. With its variable-speed compressor, excellent humidity control, durable construction, and smart features, it promises comfort and reliability suitable for any residential space. By choosing Goodman, homeowners can invest in a quality HVAC system designed to meet modern needs and preferences.