CIRCULATING AIR AND FILTERS

air temperature rise must be within the range listed on the fur- nace nameplate. Should this appliance be converted to LP, refer to the instructions included in the factory authorized LP conversion kit.

HIGH ALTITUDE DERATE

IMPORTANT NOTE: The furnace will naturally derate itself with altitude. Do not attempt to increase the firing rate by changing orifices or increasing the manifold pressure. This can cause poor combustion and equipment failure.

High altitude installations may require both a pressure switch and an orifice change. These changes are necessary to com- pensate for the natural reduction in the density of both the gas fuel and the combustion air at higher altitude.

For installations above 7000 feet, please refer to your distribu- tor for required kit(s).

Gas

Altitude

Kit

Orifice

Manifold Pressure

Pressure

 

 

Switch Change

High Stage

Low Stage

 

 

 

 

 

 

Natural

 

None

#43

3.5" w.c.

1.9" w.c.

None

 

0-7000

 

 

 

 

 

Propane

LPM-05*1

#55

10.0" w.c.

6.0" w.c.

None

 

LPM-06*2

 

 

 

 

 

 

 

 

 

 

 

 

 

1LPM-05* supports White-Rodgers 2-stage valve only

2LPM-06* supports Honeywell and White-Rodgers 2-stage valves NOTE: In Canada, gas furnaces are only certified to 4500 feet.

Contact the distributor for a tabular listing of appropriate manufacturer’s kits for propane gas and/or high altitude instal- lations. The indicated kits must be used to insure safe and proper furnace operation. All conversions must be performed by a qualified installer, or service agency.

PROPANE GAS CONVERSION

WARNING

POSSIBLE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH MAY OCCUR IF THE CORRECT CONVERSION KITS ARE NOT INSTALLED. THE APPROPRIATE KITS MUST BE APPLIED TO ENSURE SAFE AND PROPER FURNACE OPERATION. ALL CONVERSIONS MUST BE PERFORMED BY A QUALIFIED INSTALLER OR SERVICE AGENCY.

This unit is configured for natural gas. The appropriate manufacturer’s propane gas conversion kit, must be applied for propane gas installations. Refer to the “Propane Gas and/or High Altitude Installations” section for details.

Contact your distributor for a tabular listing of appropriate manufacturer’s kits for propane gas and/or high altitude instal- lations. The indicated kits must be used to insure safe and proper furnace operation. All conversions must be performed by a qualified installer, or service agency.

GAS PIPING CONNECTIONS

WARNING

TO AVOID POSSIBLE UNSATISFACTORY OPERATION OF EQUIPMENT DAMAGE DUE TO UNDERFIRING OR EQUIPMENT, USE THE PROPER SIZE OF NATURAL/PROPANE GAS PIPING NEEDED WHEN RUNNING PIPE FROM THE METER/TANK TO THE FURNACE.

When sizing a trunk line, be sure to include all appliances which will operate simultaneously.

The gas piping supplying the furnace must be properly sized based on the gas flow required, specific gravity of the gas, and length of the run. The gas line installation must comply with local codes, or in their absence, with the latest edition of the National Fuel Gas Code, NFPA 54/ANSI Z223.1.

Natural Gas Capacity of Pipe

In Cubic Feet of Gas Per Hour (CFH)

Length of

 

Nominal Black Pipe Size

 

Pipe in Feet

1/2"

3/4"

1"

1 1/4"

1 1/2"

 

10

132

278

520

1050

1600

 

20

92

190

350

730

1100

 

30

73

152

285

590

980

 

40

63

130

245

500

760

 

50

56

115

215

440

670

 

60

50

105

195

400

610

 

70

46

96

180

370

560

 

80

43

90

170

350

530

 

90

40

84

160

320

490

100

38

79

150

305

460

(Pressure 0.5 psig or less and pressure drop of 0.3" W.C.; Based on

 

0.60 Specific Gravity Gas)

 

 

 

 

 

CFH =

BTUH Furnace Input

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating Value of Gas (BTU/Cubic Foot)

 

 

 

 

 

To connect the furnace to the building’s gas piping, the installer must supply a ground joint union, drip leg, manual shutoff valve, and line and fittings to connect to gas valve. In some cases, the installer may also need to supply a transition piece from 1/ 2" pipe to a larger pipe size.

The following stipulations apply when connecting gas piping.

Use black iron or steel pipe and fittings for the building piping.

Use pipe joint compound on male threads only. Pipe joint compound must be resistant to the action of the fuel used.

Use ground joint unions.

Install a drip leg to trap dirt and moisture before it can enter the gas valve. The drip leg must be a minimum of three inches long.

Install a 1/8" NPT pipe plug fitting, accessible for test gage connection, immediately upstream of the gas supply connection to the furnace.

Use two pipe wrenches when making connection to the gas valve to keep it from turning. The orientation of the gas valve on the manifold must be maintained as shipped from the factory.

19

Image 19
Contents Installation Instructions for *D, MVC8 GAS Furnace Upright Installations Table of Contents What to do if YOU Smell GAS Safety PrecautionsKeep this literature in a safe place for future reference Product ApplicationProduct Description Location Requirements and ConsiderationsNational Fire Protection Association, Inc CSA InternationalClearances and Accessibility Combustion & Ventilation Category Following vent testing procedure is reproduced fromCategory I Venting Vertical Venting Exterior Masonry Chimneys Category I Furnaces onlyExteriormasonrychimneyscategoryifurnacesonly Proper Chimney Termination? Check Check 3 Chimney Crown Condition Electrical Connections High Voltage Important Note Single Stage Heating with Single Stage Cooling Thermostat Wiring DiagramsGAS Supply and Piping Accessories WiringGas Altitude Kit Orifice Manifold Pressure Circulating AIR and FiltersGeneral Furnace Layout Propane Gas Installation Typ Checking Static Pressure 80% Furnace Shown, 90% Similar START-UP Procedure and AdjustmentUpright Installations Honeywell Model VR9205 Two-Stage White-Rodgers Model 36G54 Two-StageHoneywell Model VR9205 Connected to Manometer White-Rodgers Model 36G54 Connected to ManometerMeasuring Inlet Gas Pressure Alt. Method Example Temperature Rise MeasurementSwitch Bank S4 Heat Off Delay Dipswitches Switch Bank S4Comfortnet System Comfortnet SystemCTK01AA System Wiring using Four-WiresTo step to the next item Configuration Cool Airflow CL CFM Normal Sequence of Operation Operational Checks & Safety Circuit DescriptionOperational Checks Safety Circuit Description Troubleshooting & MaintenanceTroubleshooting Miscellaneous MaintenanceRepair and Replacement Parts Before Leaving AN InstallationInternal Troubleshooting ChartLimit Message ChartInvalid Trips Status Codes AIR Flow Data DIP SwitchesRD WH MVC8AA Wiring DiagramMVC8AB, *DVC8AA Wiring Diagram

VC8 specifications

Goodman Manufacturing has established itself as a leading provider of quality heating, ventilation, and air conditioning (HVAC) systems. Among its impressive lineup is the Goodman VC8, a versatile and efficient variable-capacity air conditioner that stands out due to its innovative design and advanced technologies.

The Goodman VC8 is known for its superior energy efficiency, featuring a SEER (Seasonal Energy Efficiency Ratio) rating higher than 20. This means that it operates efficiently across various climatic conditions, ensuring optimal cooling with minimal energy consumption. The high SEER rating not only translates to lower energy bills but also contributes to a reduced environmental footprint, making it a smart choice for eco-conscious consumers.

One of the standout features of the VC8 is its variable-speed compressor, which allows the system to adjust its output based on the cooling needs of the space. This technology enables the unit to run at lower speeds for longer periods, maintaining a consistent temperature while reducing energy usage. The variable-speed operation also contributes to quieter operation compared to traditional air conditioning systems. Homeowners can enjoy a peaceful indoor environment without the disruptive noise commonly associated with air conditioning units.

In terms of comfort, the Goodman VC8 employs advanced humidity control features, ensuring that moisture is efficiently managed within the space. This not only enhances comfort levels but also helps to prevent issues related to excessive humidity, such as mold growth and structural damage.

The VC8 is designed for reliable performance and durability, with its robust construction and dependable components. Goodman manufactures its products with high-quality materials to withstand the rigors of daily use and various weather conditions, ensuring long-lasting operation.

Additionally, the VC8 incorporates smart technology features, including compatibility with Wi-Fi-enabled thermostats. Homeowners can easily monitor and control their system remotely, providing convenience and peace of mind.

The Goodman VC8 is an exemplary solution for those looking for an energy-efficient, advanced air conditioning system. With its variable-speed compressor, excellent humidity control, durable construction, and smart features, it promises comfort and reliability suitable for any residential space. By choosing Goodman, homeowners can invest in a quality HVAC system designed to meet modern needs and preferences.