Lenox Lennox Merit Series Gas Furnace Manual & Installation Instructions

Page 1

E 2011 Lennox Industries Inc.

Dallas, Texas, USA

AIR FLOW

UPFLOW

AIR FLOW

AIR FLOW

HORIZONTAL LEFT

HORIZONTAL RIGHT

INSTALLATION

INSTRUCTIONS

ML180UHE

MERIT® SERIES GAS FURNACE

UPFLOW / HORIZONTAL AIR DISCHARGE

506810−01

06/2011

Supersedes 506732−01

Litho U.S.A.

THIS MANUAL MUST BE LEFT WITH THE HOMEOWNER FOR FUTURE REFERENCE

This is a safety alert symbol and should never be ignored. When you see this symbol on labels or in manuals, be alert to the potential for personal injury or death.

WARNING

Improper installation, adjustment, alteration, service or maintenance can cause property damage, person- al injury or loss of life. Installation and service must be performed by a licensed professional installer (or equivalent), service agency or the gas supplier.

CAUTION

As with any mechanical equipment, personal injury can result from contact with sharp sheet metal edges. Be careful when you handle this equipment.

Table of Contents

Unit Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Parts Arrangement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

ML180UHE Gas Furnace . . . . . . . . . . . . . . . . . . . . . . . . . 4

Shipping and Packing List . . . . . . . . . . . . . . . . . . . . . . . . 4

Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Use of Furnace as a Construction Heater . . . . . . . . . . . 5 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Combustion, Dilution & Ventilation Air . . . . . . . . . . . . . . 6

Setting Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Duct System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Venting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Gas Piping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

Electrical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

Integrated Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

Unit Start−Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

Gas Pressure Adjustment . . . . . . . . . . . . . . . . . . . . . . . . 30

High Altitude . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

Proper Combustion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

Other Unit Adjustments . . . . . . . . . . . . . . . . . . . . . . . . . . 31

Blower Performance Data . . . . . . . . . . . . . . . . . . . . . . . . 33

Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

Planned Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

Repair Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

Integrated Control Diagnostic Codes . . . . . . . . . . . . . . . 38

Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

06/11

 

506810−01

*2P0611*

Page 1

*P506810-01*

 

 

Image 1
Contents Table of Contents Installation Instructions ML180UHETOP View Unit Dimensions − inches mmMake−Up Box Heat Exchanger Combustion Air Inducer Parts ArrangementBurner Box Gas ValveML180UHE Gas Furnace Safety InformationShipping and Packing List General Use of Furnace as Construction HeaterCombustion, Dilution & Ventilation Air Equipment in Confined Space ALL AIR from Inside Equipment in Confined Space Setting Equipment Return Air Right Horizontal Application Installation Clearances Top LeftEnd Bottom Typical Horizontal ApplicationDuct System FiltersUpflow Position VentingTop Vent Discharge Left Side Vent DischargeHorizontal Left Position Horizontal Left Position Horizontal Right PositionSide Vent Discharge Side Vent Discharge − no modifications necessaryVent Connection Upflow and Horizontal Position Common Venting Using Metal−Lined Masonry Chimney −1/2 18 − The common vent diameter must always be at least as Cated or common venting system, you must inspectFeet FAN + FAN FAN + NAT 130 Carbon Monoxide Poisoning Hazard − In some localities, codes may require the installation Ers or straps. Install a drip leg in vertical pipe runs toGas Piping Gas supply piping should not allow more than 0.5W.C. dropLeft−Side Air Discharge Horizontal ApplicationRight−Side Air Discharge Electrical Interior MAKE−UP BOX InstallationElectrostatic Discharge ESD Thermostat Designations ML180UHE Schematic Wiring Diagram and Sequence of Operation Integrated Control Typical ML180UHE Field Wiring DiagramUnit Start−Up For Your Safety Read Before LightingGAS Meter Clocking Chart Gas Pressure AdjustmentProper Combustion High AltitudeManifold Pressure Settings at all Altitudes Other Unit AdjustmentsNo Jumper Heat FAN-OFF Time in Seconds995 1380975 115 945 1345Order to maintain proper air velocity Single Side Return Air − Air volumes in bold require field640 1940 420 1750 310 230Electrical SHOCK, Fire Or Explosion Hazard ServiceHeat Exchanger Removal ML180UHE BURNER, Combustion AIR Inducer Assembly−090, −110 −135 units −045 and −070 unitsRepair Parts List Planned ServiceRED LED Integrated Control Diagnostic CodesHeating Sequence of Operation Normal Heating Mode Abnormal Heating ModeHeating Sequence Cooling Sequence of Operation Normal Cooling Mode Abnormal Cooling ModeContinuous FAN Sequence of Operation Start−Up & Performance Check List Temperature Rise Cooling ModeUnit Operation Drain Line