Trane RT-PRC005 manual Model Number Description, 036 11 12,13

Page 10

Model

Number

Description

 

T

S

C

036

A

3

R

B

A ** C

0

0 0

A

1

0 0

0

1

A

1

 

1

2

3

4,5,6

7

8

9

10

11 12,13 14

15

16 17

18

19

20 21

22

23

24

25

DIGIT 1 - Unit Function

 

 

DIGIT 11 - Minor Design Sequence

 

DIGIT 20 - Convenience Outlet

 

 

 

T

= DX Cooling

 

 

A = First Sequence

 

 

 

0 = No Convenience Outlet

 

 

 

DIGIT 2 - Efficiency

 

 

 

 

 

 

 

 

 

A = Unpowered Convenience Outlet

 

 

 

DIGITS 12, 13 - Service Sequence

 

B = Powered Convenience Outlet

 

 

S

= Standard Efficiency

 

 

**=

Factory Assigned

 

 

 

(3 phase only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H

= High Efficiency

 

 

 

 

 

 

 

 

 

DIGIT 21 - Communications Options

 

 

 

 

 

 

DIGIT 14 - Fresh Air Selection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIGIT 3 - Airflow

C = Convertible

DIGITS 4,5,6 - Nominal Gross Cooling Capacity (MBh)

036

=

3Ton

048

=

4Ton

060

=

5Ton

072

=

6Ton

090

=

7½Ton, Single Compressor

092

=

7½Ton, Dual Compressor

102

=

8½Ton

120

=

10Ton

DIGIT 7 - Major Design Sequence

A = First

DIGIT 8 - UnitVoltage

1 = 208-230/60/1

3 = 208-230/60/3

4 = 460/60/3 W= 575/60/3 K = 380/60/3

DIGIT 9 - Unit Controls

E = Electromechanical

R = ReliaTel™Microprocessor

DIGIT 10 - Heating Capacity

0= No Electric Heat A = 5 kW (1 phase) B = 6 kW (3 phase) C = 9 kW (3 phase) D = 10 kW (1 phase) E = 12 kW (3 phase) F = 14 kW (1 phase)

G = 18 kW (1 and 3 phase) J = 23 kW (3 phase)

K = 27 kW (3 phase) N = 36 kW (3 phase) P = 54 kW (3 phase)

0 = No Fresh Air

A= Manual Outside Air Damper 0-50%

B= Motorized Outside Air Damper 0-50%

C= Economizer, Dry Bulb 0-100% without Barometric Relief

D= Economizer, Dry Bulb 0-100%

with Barometric Relief

E= Economizer, Reference Enthalpy 0-100% without Barometric Relief

F= Economizer, Reference Enthalpy 0-100% with Barometric Relief

G= Economizer, Comparative Enthalpy 0-100% without Barometric Relief

H= Economizer, Comparative Enthalpy 0-100% with Barometric Relief

DIGIT 15 - Supply Fan/DriveType/Motor

0= Standard Drive

1= Oversized Motor

2= Optional Belt Drive Motor

DIGIT 16 - Hinged Service Access/Filters

0 = Standard Panels/Standard Filters

A= Hinged Access Panels/Standard Filters

B= Standard Panels/2” Pleated Filters

C= Hinged Access Panels/2” Pleated Filters

DIGIT 17 - Condenser Coil Protection

0 = Standard Coil

1= Standard Coil with Hail Guard

2= Epoxy Coated Condenser Coil

3= Epoxy Coated Condenser Coil with Hail Guard

DIGIT 18 -Through the Base Provisions

0= NoThrough the Base Provisions A = Through the Base Electric

DIGIT 19 - Disconnect/Circuit Breaker (3 phase only)

0= No Disconnect or Circuit Breaker

1= Non-Fused Disconnect

2= Circuit Breaker

0= No Communications Interface

1= Trane Communications Interface

2= LonTalk® Communications Interface

3= Novar 2024 Controls

4= Novar 3051 Controls

DIGIT 22 - Refrigeration System Option

0= Standard Refrigeration System A = Thermal Expansion Valve (TXV)

B = Dehumidification (Hot Gas Reheat Coil)

DIGIT 23 - Refrigeration Controls

0 = No Refrigeration Control

1= High Pressure Control

2= Frostat

3= Crankcase Heater

4= High Pressure Control and Frostat

5= High Pressure Control and Crankcase Heater

6= Frostat and Crankcase Heater

7= High Pressure Control, Frostat and Crankcase Heater

DIGIT 24 - Smoke Detector

0 = No Smoke Detector

A= Return Air Smoke Detector

B= Supply Air Smoke Detector

C= Supply and Return Air Smoke Detectors

DIGIT 25 - Monitoring Controls

0= No Monitoring Control

1= Clogged Filter Switch

2= Fan Failure Switch

3= Discharge Air SensingTube

4= Clogged Filter Switch and Fan Fail Switch

5= Clogged Filter Switch and Discharge Air SensingTube

6= Fan Fail Switch and Discharge Air SensingTube

7= Clogged Filter and Fan Fail Switches and Discharge Air SensingTube

8= Novar Return Air Sensor

Example:

Model number TSC036A3RBA**C000A10001A1 describes a unit with the following characteristics: DX Cooling, 3 ton nominal cooling capacity, 208-230/60/3 power supply, ReliaTel™ controls, 6 kW electric heater model. 0-100% dry bulb economizer without barometric relief, standard direct drive motor, standard access panels/ filters, standard condenser coil with no coil protection, through the base electric, non-fused disconnect, no convenience outlet or communications interface, standard refrigeration coil, high pressure control, return air smoke detector, and clogged filter switch.

10

RT-PRC005-EN

Image 10
Contents Packaged Cooling with Electric Heat Rooftop Units Introduction American Standard Inc. All rights reservedContents Features and Benefits Standardized Components Easy Access LowVoltageTerminal BoardSingle-Side Service LowVoltage ConnectionsClogged Filter/Fan Fail Switches Hinged Access DoorsAccess EconomizerVariTrac Quality And ReliabilityTestingWe test designs at our factory not on our customers ReliaTelClearance Requirements Barometric ReliefCondensateTrap Unit PitchHeating Capacity Step Selection ProcedureCooling Capacity Step Air Delivery SelectionModel Number Description 036 11 12,13Data General5Ton Table GD 1 General DataEER2 10TonTable GD 2- General Data Outdoor Sound Rating dB4 Outdoor Coil -TypeOptional Hot Gas Reheat Coil -Type Table GD 3 General DataSeer / EER2 Refrigerant Charge Lbs of R-224Integrated Part LoadValue IPLV3 Table GD 4- General DataMotor RPM Standard/Oversized 1750 TSC048A1 Performance4Ton MBH SHC MBH MBH SHC MBH SHC MBH SHCMBH MBH SHC½Ton MBH SHC MBH½, 8½Ton 10 Ton MBH SHC MBH SHC MBH 69.3 34.7 53.7 AmbientTemperature F 105 11524.8 51.4 45.6 60.11300 100062.9 65.3 57.2 72.2 74.5 61.4 56.6 73.6 42.568.2 73.8 51.7 74.7 75.3 70.6½, 10 Ton 107.6 118.4113.2 40.0 79.7TSC036A ESPESP BHP TSC048ATable PD-22 3TonTable PD-21 HP Standard Motor Field Supplied High Static DriveTable PD-23 HP Standard MotorCFM RPM BHP BHP RPM BHP RPM BHP Table PD-25Table PD-26 HP Standard Motor & Field SuppliedTable PD-28 TonTable PD-27 HP Oversized Motor & DriveTable PD-30 Table PD-29HP Standard Motor & High Static Drive Table PD-32 ½ TonTable PD-31 HP Oversized MotorTable PD-34 Table PD-33HP Standard Motor & Drive HP Oversized Motor & Drive Table PD-36 Table PD-35HP Standard Motor & Field Supplied Low Static Drive THC060A CFM ESP BHPTable PD-38 Table PD-39HP Standard Motor & Field Supplied High Static Drive Table PD-40Table PD-41 HP Standard Motor Field Supplied High Static Drive2PD-43 Static Drive Accessory Kit Motor & DriveTable PD-42 HP Standard Motor & Low HPStandardTable PD-44 Table PD-45HP Standard Table PD-46Table PD-47 Motor & Drive Or 2 HP Oversized Motor & DriveTable PD-48 Table PD-49Table PD-51 Table PD-50HP Standard Motor & Field Supplied LowStaticDrive1 Table PD-52 HP Standard Motor & Low Static Drive Accessory KitTable PD-53 Table PD-55 Static DriveAccessory KitTable PD-54 HP Standard Motor & LowTable PD-56- Standard Motor & Sheave/Fan Speed Rpm Table PD-59- Outdoor Sound Power Level dB ref -12WattsPerformance Data Table PD-58- Oversized Motor & Drive Sheave/Fan Speed RpmTHC036A TSC090AK Table PD-62- Auxiliary Electric Heat CapacityTSC060AK TSC102AKTons Table PD-65- Hot Gas ReheatTemperature Rise3Scfm 10TonsRemote Sensor Humidity Sensor Field installed, wall-mountedZone Controls Automatic Changeover One HeatElectrical Standard Table ED-1 UnitWiring Standard EfficiencyDataEfficiency Table ED-2 UnitWiring High Efficiency Electrical High208/230 Volts Single Phase 208/230 Volts Three PhaseVolts Three Phase Volts Three Phase 208/230 Volts Single Phase Electrical BAYHTRT354AElectrical Data BAYHTRT454ABAYHTRRW06A THC036AW BAYHTRRW12A BAYHTRR110A BAYHTRR114A BAYHTRR105A FLA LRA TSC036A4 460 3450 34503450 11.3 575 3450Table ED-15- Electrical Characteristics Power Exhaust Power Wires + 1 Ground Wire three phase Jobsite ConnectionsDimensional Data3-5TonsData3-5Tons Downflow Duct Connections Field Fabricated Data6-10Tons 10Tons Unit Clearance and Roof Opening 10Tons Roof Curb 10Tons Downflow Duct Connections Field FabricatedData Accessories DimensionalSwing Diameter for Hinged Doors Option 10Tons Options TableW-2 Factory-installed Options Net Weights Lbs1,2 WeightsTHC048A Mechanical Specifications Accessories/Options Control Options PL-UN-RT-TSC/THC 3-10TONS-PRC005-EN-03-03 PL-UN-RT-TSC/THC 3-10TONS-PRC005-EN-02-03