Features and Benefits

Standardized Components

Components are placed in the same location on all Precedent™ units. Familiarize yourself with one Precedent and you are familiar with every Precedent.

Easy Access LowVoltageTerminal Board

Precedent’s LowVoltageTerminal Board is external to the electrical control cabinet. It is extremely easy to locate and attach the thermostat wire.This is another cost and time saving installation feature.

LowVoltage Connections

The wiring of the low voltage connections to the unit and the zone sensors is as simple as 1-1, 2-2, and 3-3.This simplified system makes it easy for the installer to wire

Single-Side Service

Single-side service is standard on all Precedent units.

Flexible Applications

Only two roof curbs for the 3-10 ton Precedent line. . .simplifies curb selection.

Standard or High Efficiency Cooling

Electromechanical or ReliaTel microprocessor controls to meet either the simple or the more complex application.

Airflow is outstanding.The Precedent can replace an older machine with old ductwork and, in many cases, improve comfort through better air distribution.

Belt or direct drive — standard or oversized supply fan motors meet a wide airflow range.

Precedent offers ultimate flexibility. Options and components are not pre- packaged at the factory. Units are built to order in our standard “shortest in the industry” ship cycle time.

Micro Controls

Several years ago,Trane was the first to introduce microprocessor controls into the Light Commercial Market.That design, along with immeasurable experience, has provided the technology forTrane’s second-generation ReliaTel™ microprocessor controls.

ReliaTel™ Micro:

Provides unit control for heating, cooling, and ventilating by utilizing input from sensors that measure outdoor and indoor temperature.

Improves quality and reliability through the use of time-tested microprocessor controls and logic.

Prevents the unit from short cycling, considerably improving compressor life.

Ensures that the compressor will run for a specific amount of time, which allows oil to return for better lubrication, enhancing the reliability of the compressor.

Reduces the number of components required to operate the unit, thereby reducing possibilities for component failure.

Eliminates the need for field-installed components with its built-in anti-short- cycle timer, time delay relay and minimum ‘’on’’ time controls.These controls are factory tested to assure proper operation.

Requires no special tools to run the Precedent unit through its paces during testing. Simply place a jumper between Test 1 andTest 2 terminals on the Low VoltageTerminal Board and the unit will walk through its operational steps.The unit automatically returns control to the zone sensor after stepping through the test mode a single time, even if the jumper is left on the unit.

As long as the unit has power and the LED is lit, the Micro is operational.The light indicates that the Micro is functioning properly.

Features expanded diagnostic capabilities when used withTrane’s Integrated ComfortTM Systems.

As an energy benefit, softens electrical ‘’spikes’’ by staging on fans, compressors and heaters.

The Intelligent Fallback or Adaptive Control is a benefit to the building occupant. If a component goes astray, the unit will continue to operate at predetermined temperature set points.

Intelligent Anticipation is a standard feature of the Micro. Functioning constantly, the Micro and zone sensors work together in harmony, to provide tight comfort control.

Electromechanical Controls

For the simpler job that does not require a building automation system, or expanded diagnostics capabilities, Precedent offers electromechnical controls. This 24-volt control includes the control transformer, contactor pressure lugs for power wiring.

RT-PRC005-EN

5

Image 5
Contents Packaged Cooling with Electric Heat Rooftop Units American Standard Inc. All rights reserved IntroductionContents Features and Benefits Single-Side Service Easy Access LowVoltageTerminal BoardStandardized Components LowVoltage ConnectionsAccess Hinged Access DoorsClogged Filter/Fan Fail Switches EconomizerWe test designs at our factory not on our customers Quality And ReliabilityTestingVariTrac ReliaTelCondensateTrap Barometric ReliefClearance Requirements Unit PitchCooling Capacity Step Selection ProcedureHeating Capacity Step Air Delivery Selection036 11 12,13 Model Number Description5Ton GeneralData Table GD 1 General DataTable GD 2- General Data 10TonEER2 Outdoor Sound Rating dB4 Outdoor Coil -TypeSeer / EER2 Table GD 3 General DataOptional Hot Gas Reheat Coil -Type Refrigerant Charge Lbs of R-224Motor RPM Standard/Oversized 1750 Table GD 4- General DataIntegrated Part LoadValue IPLV3 4Ton PerformanceTSC048A1 MBH SHC MBH MBH SHC MBH SHC MBH SHCMBH SHC MBHMBH SHC MBH ½Ton½, 8½Ton 10 Ton MBH SHC MBH SHC MBH 24.8 51.4 45.6 AmbientTemperature F 105 11569.3 34.7 53.7 60.162.9 65.3 57.2 10001300 68.2 73.8 51.7 56.6 73.6 42.572.2 74.5 61.4 74.7 75.3 70.6½, 10 Ton 113.2 40.0 118.4107.6 79.7ESP BHP ESPTSC036A TSC048ATable PD-21 3TonTable PD-22 HP Standard Motor Field Supplied High Static DriveHP Standard Motor Table PD-23Table PD-26 Table PD-25CFM RPM BHP BHP RPM BHP RPM BHP HP Standard Motor & Field SuppliedTable PD-27 TonTable PD-28 HP Oversized Motor & DriveHP Standard Motor & High Static Drive Table PD-29Table PD-30 Table PD-31 ½ TonTable PD-32 HP Oversized MotorHP Standard Motor & Drive HP Oversized Motor & Drive Table PD-33Table PD-34 HP Standard Motor & Field Supplied Low Static Drive Table PD-35Table PD-36 CFM ESP BHP THC060ATable PD-39 Table PD-38Table PD-41 Table PD-40HP Standard Motor & Field Supplied High Static Drive HP Standard Motor Field Supplied High Static Drive2Table PD-42 Static Drive Accessory Kit Motor & DrivePD-43 HP Standard Motor & Low HPStandardTable PD-45 Table PD-44Table PD-47 Table PD-46HP Standard Motor & Drive Or 2 HP Oversized Motor & DriveTable PD-49 Table PD-48HP Standard Motor & Field Supplied LowStaticDrive1 Table PD-50Table PD-51 Table PD-53 HP Standard Motor & Low Static Drive Accessory KitTable PD-52 Table PD-54 Static DriveAccessory KitTable PD-55 HP Standard Motor & LowPerformance Data Table PD-59- Outdoor Sound Power Level dB ref -12WattsTable PD-56- Standard Motor & Sheave/Fan Speed Rpm Table PD-58- Oversized Motor & Drive Sheave/Fan Speed RpmTHC036A TSC060AK Table PD-62- Auxiliary Electric Heat CapacityTSC090AK TSC102AKScfm Table PD-65- Hot Gas ReheatTemperature Rise3Tons 10TonsZone Controls Humidity Sensor Field installed, wall-mountedRemote Sensor Automatic Changeover One HeatDataEfficiency Table ED-1 UnitWiring Standard EfficiencyElectrical Standard Electrical High Table ED-2 UnitWiring High Efficiency208/230 Volts Three Phase 208/230 Volts Single PhaseVolts Three Phase Volts Three Phase 208/230 Volts Single Phase BAYHTRT354A ElectricalBAYHTRT454A Electrical DataBAYHTRRW06A THC036AW BAYHTRRW12A BAYHTRR110A BAYHTRR114A BAYHTRR105A FLA LRA 3450 11.3 3450TSC036A4 460 3450 575 3450Table ED-15- Electrical Characteristics Power Exhaust Jobsite Connections Power Wires + 1 Ground Wire three phaseData3-5Tons DimensionalData3-5Tons Downflow Duct Connections Field Fabricated Data6-10Tons 10Tons Unit Clearance and Roof Opening 10Tons Downflow Duct Connections Field Fabricated 10Tons Roof CurbSwing Diameter for Hinged Doors Option DimensionalData Accessories 10Tons Options THC048A WeightsTableW-2 Factory-installed Options Net Weights Lbs1,2 Mechanical Specifications Accessories/Options Control Options PL-UN-RT-TSC/THC 3-10TONS-PRC005-EN-02-03 PL-UN-RT-TSC/THC 3-10TONS-PRC005-EN-03-03